Product successfully added to your shopping cart
DILET70-W
048899
EATON-MOELLER
1
Multi-function relay, 1W, 0.05-60h, with potentiometer connection, 400VAC
Contactors up to 170A
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | DILET timing relays | ||
Basic function | Timer relays | ||
Function | Multi-functional On-delayed Off-delayed Fleeting contact on energization Fleeting contact on de-energization Flashing, pulse initiating On- and Off-delayed Pulse forming Pulse generating | ||
with connection for potentiometer Adjustable timing functions | |||
Number of changeover contacts | 1 | ||
Time range | 0.05 s - 60 h | ||
Time range | 0.05 - 1s 0.15 - 3 s 0.5 - 10 s 3 - 60 s 0,15 - 3 min 0.5 - 10 min 3 - 60 min 0.15 - 3 h 0.5 - 10 h 3 - 60 h | ||
Rated operational current | |||
AC-11 | |||
230 V | Ie | A | 3 |
380 V 400 V 415 V | Ie | A | 3 |
AC-15 | |||
220 V 230 V 240 V | Ie | A | 3 |
Voltage range | ULN | V | 400 V AC, 50/60 Hz |
Width | mm | 45 | |
Terminal marking according to EN 50042 | |||
General | |||
Standards | Standard IEC/EN 61812 VDE 0435 | ||
Lifespan, mechanical | |||
AC operated | Operations | x 106 | 30 |
DC operated | Operations | x 106 | 30 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -20 - +60 | |
Enclosed | °C | - 20 - + 45 | |
Mounting position | As required | ||
Mechanical shock resistance (IEC/EN 60068-2-27) | |||
Half-sinusoidal shock, 20 ms | g | ||
Make contact | g | 4 | |
Degree of protection | |||
Terminals | IP20 | ||
Weight | kg | 0.09 | |
Terminal capacities | mm2 | ||
Solid | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Flexible with ferrule | mm2 | 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) | |
Solid or stranded | AWG | 1 x (18 - 14) | |
Contacts | |||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Overvoltage category/pollution degree | III/2 | ||
Rated insulation voltage | Ui | V AC | 600 |
Rated operational voltage | Ue | V AC | 440 |
Safe isolation to EN 61140 | |||
between coil and auxiliary contacts | V AC | 250 | |
between the auxiliary contacts | V AC | 250 | |
Making capacity | |||
AC-14 cos ϕ = 0.3400 V | A | 48 | |
AC-15 cos ϕ = 0.3 220 V | A | 50 | |
DC-11 L/R - 40 ms | x Ie | 1.1 | |
Breaking capacity | |||
AC-14 cos ϕ = 0.3440 V | A | 3 | |
AC-15 cos ϕ = 0.3220 V | A | 3 | |
DC-11 L/R - 40 ms | x Ie | 1.1 | |
Rated operational current | Ie | A | |
AC--14 | |||
440 V | Ie | A | 3 |
AC-15 | |||
220 V 230 V 240 V | Ie | A | 3 |
DC-11 | |||
Note | Making and breaking conditions to DC13, time constant as stated | ||
L/R max. 15 ms | A | ||
24 V | Ie | A | 1.5 |
L/R max. 50 ms | A | 1.2 | |
Conv. thermal current | Ith | A | 6 |
Short-circuit rating without welding | |||
Note | When supplied directly from mains or transformer > 1000 VA | ||
Max. fuse, make contacts | A gG/gL | 6 | |
Max. fuse, break contacts | A gG/gL | 6 | |
Magnet systems | |||
Rated operational voltage | Ue | V | |
AC | 400 | ||
Voltage tolerance | x Uc | ||
Pick-up voltage | x Us | ||
Min. pick-up voltage, AC operated | x Uc | 0.85 | |
Pick-up voltage AC operated, max. | x Uc | 1.1 | |
Power consumption | |||
Pick-up AC | VA | 0.5 | |
Sealing AC | VA | 0.5 | |
Duty factor | % DF | 100 | |
Maximum operating frequency | Ops/h | 4000 | |
Minimum command time | |||
AC | ms | 50 | |
Repetition accuracy (deviation) | % | ||
Technical data for design verification | |||
Rated operational current for specified heat dissipation | In | A | 6 |
Heat dissipation per pole, current-dependent | Pvid | W | 0.9 |
Equipment heat dissipation, current-dependent | Pvid | W | 0 |
Static heat dissipation, non-current-dependent | Pvs | W | 0.5 |
Heat dissipation capacity | Pdiss | W | 0 |
Operating ambient temperature min. | °C | -20 | |
Operating ambient temperature max. | °C | 60 | |
IEC/EN 61439 design verification | |||
10.2 Strength of materials and parts | |||
10.2.2 Corrosion resistance | Meets the product standard's requirements. | ||
10.2.3.1 Verification of thermal stability of enclosures | Meets the product standard's requirements. | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | Meets the product standard's requirements. | ||
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects | Meets the product standard's requirements. | ||
10.2.4 Resistance to ultra-violet (UV) radiation | Meets the product standard's requirements. | ||
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 Mechanical impact | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.7 Inscriptions | Meets the product standard's requirements. | ||
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 Clearances and creepage distances | Meets the product standard's requirements. | ||
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | ||
10.7 Internal electrical circuits and connections | Is the panel builder's responsibility. | ||
10.8 Connections for external conductors | Is the panel builder's responsibility. | ||
10.9 Insulation properties | |||
10.9.2 Power-frequency electric strength | Is the panel builder's responsibility. | ||
10.9.3 Impulse withstand voltage | Is the panel builder's responsibility. | ||
10.9.4 Testing of enclosures made of insulating material | Is the panel builder's responsibility. | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | ||
10.11 Short-circuit rating | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.12 Electromagnetic compatibility | Is the panel builder's responsibility. The specifications for the switchgear must be observed. | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Relays (EG000019) / Timer relay (EC001439) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Relay and socket / Timed relay ([email protected] [AKF092010]) | |||
Type of electric connection | Screw connection | ||
Function delay-on energization | Yes | ||
Function delay on de-energization | Yes | ||
Function floating contact on energization | Yes | ||
Function floating contact on de-energization | Yes | ||
Function star-delta | No | ||
Function pulse shaping | Yes | ||
Function flashing, starting with pause, fixed time | Yes | ||
Function flashing, starting with pulse, fixed time | Yes | ||
Clock function, starting with pause, variable | Yes | ||
Clock function, starting with pulse, variable | Yes | ||
With plug-in socket | No | ||
Remote operation possible | Yes | ||
Suitable only for remote control | No | ||
Pluggable on auxiliary contact block | No | ||
Rated control supply voltage Us at AC 50HZ | V | 400 - 400 | |
Rated control supply voltage Us at AC 60HZ | V | 400 - 400 | |
Rated control supply voltage Us at DC | V | 0 - 0 | |
Voltage type for actuating | AC | ||
Time range | s | 0.05 - 216000 | |
Number of outputs, undelayed, normally closed contact | 0 | ||
Number of outputs, undelayed, normally open contact | 0 | ||
Number of outputs, undelayed, change-over contact | 1 | ||
Number of outputs, delayed, normally closed contact | 0 | ||
Number of outputs, delayed, normally open contact | 0 | ||
Number of outputs, delayed, change-over contact | 1 | ||
Outputs, reversible delayed/undelayed | Yes | ||
With semiconductor output | No | ||
Width | mm | 45 | |
Height | mm | 58 | |
Depth | mm | 52 |
Title: | Size: | Type: |
---|---|---|
PDF EATON SWITCHING PROTECTING MOTORS EN.pdf | 34 Mbytes | |
DILET70-W 048899 048899_EN.pdf | 518 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.