6AG1134-6PA20-7BD0 SIEMENS SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

6AG1134-6PA20-7BD0 SIEMENS SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6..

6AG1134-6PA20-7BD0

SIEMENS

SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS

SIPLUS ET 200SP AI EMETER 480 VAC ST -40...+70 °C with coating formed based on 6ES7134-6PA20-0BD0 . Module of analog inputs, AI ENERGY METER 480 VAC ST suitable for TYPE OF BU D0, channel diagnosis

More details


AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC001596 - Fieldbus, decentr. periphery - analogue I/O module

Value Unit
Type of electric connection (EF003961) -
Suitable for safety functions (EF001597) -
Number of interfaces PROFINET (EF006932) -
Appendant operation agent (Ex ia) (EF004141) -
Input, current (EF003204) -
Degree of protection (NEMA) (EF011959) -
Performance level according to EN ISO 13849-1 (EF007399) -
Category according to EN 954-1 (EF006782) -
Appendant operation agent (Ex ib) (EF004142) -
Input, resistor (EF003206) -
Supply voltage DC (EF007534) -V
Explosion safety category for dust (EF003998) -
Input, thermocouple (EF003208) -
Input, resistance thermometer (EF003207) -
Input, voltage (EF003205) -
SIL according to IEC 61508 (EF009889) -
Supporting protocol for PROFINET IO (EF007525) -
Supporting protocol for PROFIsafe (EF007526) -
Supporting protocol for other bus systems (EF003062) -
Supporting protocol for PROFIBUS (EF003052) -
Fieldbus connection over separate bus coupler possible (EF004002) -
Resolution of the analogue inputs (EF003575) -Bit
Explosion safety category for gas (EF003997) -
Supply voltage AC 50 Hz (EF007532) ['90', '293']V
Supply voltage AC 60 Hz (EF007533) ['90', '293']V
Voltage type of supply voltage (EF002991) AC
Input signal, configurable (EF003209) true
Output, current (EF003212) -
Output, voltage (EF003213) -
Output signal configurable (EF003214) -
Resolution of the analogue outputs (EF003577) -Bit
Number of analogue inputs (EF001994) 0
Number of analogue outputs (EF001995) 0
Analogue inputs configurable (EF008518) true
Analogue outputs configurable (EF008519) -
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces Wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for TCP/IP (EF003050) false
Supporting protocol for CAN (EF003053) false
Supporting protocol for INTERBUS (EF003054) false
Supporting protocol for ASI (EF003051) false
Supporting protocol for KNX (EF003055) false
Supporting protocol for Modbus (EF003057) false
Supporting protocol for Data-Highway (EF003058) false
Supporting protocol for DeviceNet (EF003059) false
Supporting protocol for SUCONET (EF003060) false
Supporting protocol for LON (EF003017) false
Supporting protocol for PROFINET CBA (EF007524) false
Supporting protocol for SERCOS (EF006657) false
Supporting protocol for Foundation Fieldbus (EF007522) false
Supporting protocol for EtherNet/IP (EF007521) false
Supporting protocol for AS-Interface Safety at Work (EF007519) false
Supporting protocol for DeviceNet Safety (EF007520) false
Supporting protocol for INTERBUS-Safety (EF006662) false
Supporting protocol for SafetyBUS p (EF007527) false
Radio standard Bluetooth (EF007178) false
Radio standard WLAN 802.11 (EF007179) false
Radio standard GPRS (EF008523) false
Radio standard GSM (EF008524) false
Radio standard UMTS (EF008525) false
IO link master (EF007298) false
System accessory (EF004118) true
Degree of protection (IP) (EF005474) IP20
Rail mounting possible (EF003972) true
Wall mounting/direct mounting (EF007020) false
Front build in possible (EF007016) true
Rack-assembly possible (EF007018) true
Width (EF000008) 20.0mm
Height (EF000040) 73.0mm
Depth (EF000049) 58.0mm


SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS
General information
Product type designationAI Energy Meter 480VAC ST
usable BaseUnitsBU type D0
Product function
● Voltage measurementYes
— with voltage transformerYes
● Current measurementYes
— without current transformerNo
— with current transformerYes
● Energy measurementYes
● Frequency measurementYes
● Power measurementYes
● Active power measurementYes
● Reactive power measurementYes
● I&M dataYes; I&M0 to I&M3
● Isochronous modeNo
Operating mode
● cyclic measurementYes
● acyclic measurementYes
● Acyclic measured value accessYes
● Fixed measured value setsYes
● Freely definable measured value setsYes
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNYes
Installation type/mounting
Mounting positionany
Supply voltage
Design of the power supplySupply via voltage measurement channel L1
Type of supply voltageAC 100 - 277 V
permissible range, lower limit (AC)90 V
permissible range, upper limit (AC)293 V
Line frequency
● permissible range, lower limit47 Hz
● permissible range, upper limit63 Hz
Power loss
Power loss, typ.0.6 W
Address area
Address space per module
● Address space per module, max.268 byte; 256 byte input / 12 byte output
Hardware configuration
Automatic encoding
● Mechanical coding elementYes
Time of day
Operating hours counter
● presentYes
Analog inputs
Cycle time (all channels), typ.50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarmYes
● Limit value alarmYes
● Hardware interruptYes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED)Yes
● Channel status displayYes; green LED
● for channel diagnosticsYes; red Fn LED
● for module diagnosticsYes; green/red DIAG LED
Integrated Functions
Measuring functions
● Measuring procedure for voltage measurementTRMS
● Measuring procedure for current measurementTRMS
● Type of measured value acquisitionseamless
● Curve shape of voltageSinusoidal or distorted
● Buffering of measured variablesYes
● Parameter length74 byte
● Bandwidth of measured value acquisition2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz
Measuring range
— Frequency measurement, min.45 Hz
— Frequency measurement, max.65 Hz
Measuring inputs for voltage
— Measurable line voltage between phase and neutral conductor277 V
— Measurable line voltage between the line conductors480 V
— Measurable line voltage between phase and neutral conductor, min.90 V
— Measurable line voltage between phase and neutral conductor, max.293 V
— Measurable line voltage between the line conductors, min.155 V
— Measurable line voltage between the line conductors, max.508 V
— Internal resistance line conductor and neutral conductor3.4 MΩ
— Power consumption per phase20 mW
— Impulse voltage resistance 1,2/50µs1 kV
— Measurement category for voltage measurement in accordance with IEC 61010-2-030CAT II; CAT III in case of guaranteed protection level of 1.5 kV
Measuring inputs for current
— measurable relative current (AC), min.1 %; Relative to the secondary rated current 5 A
— measurable relative current (AC), max.100 %; Relative to the secondary rated current 5 A
— Continuous current with AC, maximum permissible5 A; at > +60 °C max. permissible current 1 A per phase
— Apparent power consumption per phase for measuring range 5 A0.6 V·A
— Rated value short-time withstand current restricted to 1 s100 A
— Input resistance measuring range 0 to 5 A25 mΩ; At the terminal
— Surge strength10 A; for 1 minute
— Zero point suppressionParameterizable: 2 ... 250 mA, default 50 mA
Accuracy class according to IEC 61557-12
— Measured variable voltage0,2
— Measured variable current0,2
— Measured variable apparent power0.5
— Measured variable active power0.5
— Measured variable reactive power1
— Measured variable power factor0.5
— Measured variable active energy0.5
— Measured variable reactive energy1
— Measured variable neutral current0.5; calculated
— Measured variable phase angle±1 °; not covered by IEC 61557-12
— Measured variable frequency0.05
Potential separation
Potential separation channels
● between the channels and backplane busYes; 3 700V AC (type test) CAT III
Isolation
Isolation tested with2 300V AC for 1 min. (type test)
Ambient conditions
Ambient temperature during operation
● horizontal installation, min.-40 °C; = Tmin; < -25 °C min. permissible supply voltage 110 V AC
● horizontal installation, max.70 °C; = Tmax; > +60 °C max. permissible current 1 A per phase
● vertical installation, min.-40 °C; = Tmin
● vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
● Installation altitude above sea level, max.2 000 m
● Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
● Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
● Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
● Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width20 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.45 g
Other
Data for selecting a current transformer
● Burden power current transformer x/1A, min.As a function of cable length and cross section, see device manual
● Burden power current transformer x/5A, min.As a function of cable length and cross section, see device manual
last modified:08/29/2020


Product
Article Number (Market Facing Number)6AG1134-6PA20-7BD0
Product DescriptionSIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS
Product familySIPLUS analog inputs
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group473
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works37 Day/Days
Net Weight (kg)0,054 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension6,50 x 7,70 x 2,30
Package size unit of measureCM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047618085209
UPCNot available
Commodity Code90303900
LKZ_FDB/ CatalogIDA&DSE/SIP ADD
Product Group4257
Group CodeR740
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 18.07.2017
Product classB: return restricted, please contact your Siemens partner/contact
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

4,4'-isopropylidenediphenol (Bisphenol A, BPA)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-24-26-01
eClass7.127-24-26-01
eClass827-24-26-01
eClass927-24-26-01
eClass9.127-24-26-01
ETIM5EC001596
ETIM6EC001596
ETIM7EC001596
IDEA43562
UNSPSC1532-15-17-05

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.