Product successfully added to your shopping cart
6AG1134-6PA20-7BD0
SIEMENS
1
SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS
SIPLUS ET 200SP AI EMETER 480 VAC ST -40...+70 °C with coating formed based on 6ES7134-6PA20-0BD0 . Module of analog inputs, AI ENERGY METER 480 VAC ST suitable for TYPE OF BU D0, channel diagnosis
AUTOMATION SYSTEMS > SIPLUS Extreme (LOGO, S7-1200, S7-1500, etc)
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Value | Unit | |
|---|---|---|
| Type of electric connection (EF003961) | - | |
| Suitable for safety functions (EF001597) | - | |
| Number of interfaces PROFINET (EF006932) | - | |
| Appendant operation agent (Ex ia) (EF004141) | - | |
| Input, current (EF003204) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Performance level according to EN ISO 13849-1 (EF007399) | - | |
| Category according to EN 954-1 (EF006782) | - | |
| Appendant operation agent (Ex ib) (EF004142) | - | |
| Input, resistor (EF003206) | - | |
| Supply voltage DC (EF007534) | - | V |
| Explosion safety category for dust (EF003998) | - | |
| Input, thermocouple (EF003208) | - | |
| Input, resistance thermometer (EF003207) | - | |
| Input, voltage (EF003205) | - | |
| SIL according to IEC 61508 (EF009889) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Fieldbus connection over separate bus coupler possible (EF004002) | - | |
| Resolution of the analogue inputs (EF003575) | - | Bit |
| Explosion safety category for gas (EF003997) | - | |
| Supply voltage AC 50 Hz (EF007532) | ['90', '293'] | V |
| Supply voltage AC 60 Hz (EF007533) | ['90', '293'] | V |
| Voltage type of supply voltage (EF002991) | AC | |
| Input signal, configurable (EF003209) | true | |
| Output, current (EF003212) | - | |
| Output, voltage (EF003213) | - | |
| Output signal configurable (EF003214) | - | |
| Resolution of the analogue outputs (EF003577) | - | Bit |
| Number of analogue inputs (EF001994) | 0 | |
| Number of analogue outputs (EF001995) | 0 | |
| Analogue inputs configurable (EF008518) | true | |
| Analogue outputs configurable (EF008519) | - | |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 | |
| Number of HW-interfaces RS-232 (EF003021) | 0 | |
| Number of HW-interfaces RS-422 (EF003022) | 0 | |
| Number of HW-interfaces RS-485 (EF003023) | 0 | |
| Number of HW-interfaces serial TTY (EF003024) | 0 | |
| Number of HW-interfaces parallel (EF003026) | 0 | |
| Number of HW-interfaces Wireless (EF006933) | 0 | |
| Number of HW-interfaces USB (EF003025) | 0 | |
| Number of HW-interfaces other (EF003027) | 0 | |
| Supporting protocol for TCP/IP (EF003050) | false | |
| Supporting protocol for CAN (EF003053) | false | |
| Supporting protocol for INTERBUS (EF003054) | false | |
| Supporting protocol for ASI (EF003051) | false | |
| Supporting protocol for KNX (EF003055) | false | |
| Supporting protocol for Modbus (EF003057) | false | |
| Supporting protocol for Data-Highway (EF003058) | false | |
| Supporting protocol for DeviceNet (EF003059) | false | |
| Supporting protocol for SUCONET (EF003060) | false | |
| Supporting protocol for LON (EF003017) | false | |
| Supporting protocol for PROFINET CBA (EF007524) | false | |
| Supporting protocol for SERCOS (EF006657) | false | |
| Supporting protocol for Foundation Fieldbus (EF007522) | false | |
| Supporting protocol for EtherNet/IP (EF007521) | false | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | false | |
| Supporting protocol for DeviceNet Safety (EF007520) | false | |
| Supporting protocol for INTERBUS-Safety (EF006662) | false | |
| Supporting protocol for SafetyBUS p (EF007527) | false | |
| Radio standard Bluetooth (EF007178) | false | |
| Radio standard WLAN 802.11 (EF007179) | false | |
| Radio standard GPRS (EF008523) | false | |
| Radio standard GSM (EF008524) | false | |
| Radio standard UMTS (EF008525) | false | |
| IO link master (EF007298) | false | |
| System accessory (EF004118) | true | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Rail mounting possible (EF003972) | true | |
| Wall mounting/direct mounting (EF007020) | false | |
| Front build in possible (EF007016) | true | |
| Rack-assembly possible (EF007018) | true | |
| Width (EF000008) | 20.0 | mm |
| Height (EF000040) | 73.0 | mm |
| Depth (EF000049) | 58.0 | mm |
| SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS | ||
| General information | ||
| Product type designation | AI Energy Meter 480VAC ST | |
| usable BaseUnits | BU type D0 | |
| Product function | ||
| ● Voltage measurement | Yes | |
| — with voltage transformer | Yes | |
| ● Current measurement | Yes | |
| — without current transformer | No | |
| — with current transformer | Yes | |
| ● Energy measurement | Yes | |
| ● Frequency measurement | Yes | |
| ● Power measurement | Yes | |
| ● Active power measurement | Yes | |
| ● Reactive power measurement | Yes | |
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | No | |
| Operating mode | ||
| ● cyclic measurement | Yes | |
| ● acyclic measurement | Yes | |
| ● Acyclic measured value access | Yes | |
| ● Fixed measured value sets | Yes | |
| ● Freely definable measured value sets | Yes | |
| CiR - Configuration in RUN | ||
| Reparameterization possible in RUN | Yes | |
| Calibration possible in RUN | Yes | |
| Installation type/mounting | ||
| Mounting position | any | |
| Supply voltage | ||
| Design of the power supply | Supply via voltage measurement channel L1 | |
| Type of supply voltage | AC 100 - 277 V | |
| permissible range, lower limit (AC) | 90 V | |
| permissible range, upper limit (AC) | 293 V | |
| Line frequency | ||
| ● permissible range, lower limit | 47 Hz | |
| ● permissible range, upper limit | 63 Hz | |
| Power loss | ||
| Power loss, typ. | 0.6 W | |
| Address area | ||
| Address space per module | ||
| ● Address space per module, max. | 268 byte; 256 byte input / 12 byte output | |
| Hardware configuration | ||
| Automatic encoding | ||
| ● Mechanical coding element | Yes | |
| Time of day | ||
| Operating hours counter | ||
| ● present | Yes | |
| Analog inputs | ||
| Cycle time (all channels), typ. | 50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data) | |
| Interrupts/diagnostics/status information | ||
| Alarms | ||
| ● Diagnostic alarm | Yes | |
| ● Limit value alarm | Yes | |
| ● Hardware interrupt | Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value) | |
| Diagnostics indication LED | ||
| ● Monitoring of the supply voltage (PWR-LED) | Yes | |
| ● Channel status display | Yes; green LED | |
| ● for channel diagnostics | Yes; red Fn LED | |
| ● for module diagnostics | Yes; green/red DIAG LED | |
| Integrated Functions | ||
| Measuring functions | ||
| ● Measuring procedure for voltage measurement | TRMS | |
| ● Measuring procedure for current measurement | TRMS | |
| ● Type of measured value acquisition | seamless | |
| ● Curve shape of voltage | Sinusoidal or distorted | |
| ● Buffering of measured variables | Yes | |
| ● Parameter length | 74 byte | |
| ● Bandwidth of measured value acquisition | 2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz | |
| Measuring range | ||
| — Frequency measurement, min. | 45 Hz | |
| — Frequency measurement, max. | 65 Hz | |
| Measuring inputs for voltage | ||
| — Measurable line voltage between phase and neutral conductor | 277 V | |
| — Measurable line voltage between the line conductors | 480 V | |
| — Measurable line voltage between phase and neutral conductor, min. | 90 V | |
| — Measurable line voltage between phase and neutral conductor, max. | 293 V | |
| — Measurable line voltage between the line conductors, min. | 155 V | |
| — Measurable line voltage between the line conductors, max. | 508 V | |
| — Internal resistance line conductor and neutral conductor | 3.4 MΩ | |
| — Power consumption per phase | 20 mW | |
| — Impulse voltage resistance 1,2/50µs | 1 kV | |
| — Measurement category for voltage measurement in accordance with IEC 61010-2-030 | CAT II; CAT III in case of guaranteed protection level of 1.5 kV | |
| Measuring inputs for current | ||
| — measurable relative current (AC), min. | 1 %; Relative to the secondary rated current 5 A | |
| — measurable relative current (AC), max. | 100 %; Relative to the secondary rated current 5 A | |
| — Continuous current with AC, maximum permissible | 5 A; at > +60 °C max. permissible current 1 A per phase | |
| — Apparent power consumption per phase for measuring range 5 A | 0.6 V·A | |
| — Rated value short-time withstand current restricted to 1 s | 100 A | |
| — Input resistance measuring range 0 to 5 A | 25 mΩ; At the terminal | |
| — Surge strength | 10 A; for 1 minute | |
| — Zero point suppression | Parameterizable: 2 ... 250 mA, default 50 mA | |
| Accuracy class according to IEC 61557-12 | ||
| — Measured variable voltage | 0,2 | |
| — Measured variable current | 0,2 | |
| — Measured variable apparent power | 0.5 | |
| — Measured variable active power | 0.5 | |
| — Measured variable reactive power | 1 | |
| — Measured variable power factor | 0.5 | |
| — Measured variable active energy | 0.5 | |
| — Measured variable reactive energy | 1 | |
| — Measured variable neutral current | 0.5; calculated | |
| — Measured variable phase angle | ±1 °; not covered by IEC 61557-12 | |
| — Measured variable frequency | 0.05 | |
| Potential separation | ||
| Potential separation channels | ||
| ● between the channels and backplane bus | Yes; 3 700V AC (type test) CAT III | |
| Isolation | ||
| Isolation tested with | 2 300V AC for 1 min. (type test) | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● horizontal installation, min. | -40 °C; = Tmin; < -25 °C min. permissible supply voltage 110 V AC | |
| ● horizontal installation, max. | 70 °C; = Tmax; > +60 °C max. permissible current 1 A per phase | |
| ● vertical installation, min. | -40 °C; = Tmin | |
| ● vertical installation, max. | 50 °C; = Tmax | |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 2 000 m | |
| ● Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) | |
| Relative humidity | ||
| ● With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | |
| Resistance | ||
| Coolants and lubricants | ||
| — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air | |
| Use in stationary industrial systems | ||
| — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | |
| — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * | |
| — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Use on ships/at sea | ||
| — to biologically active substances according to EN 60721-3-6 | Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request | |
| — to chemically active substances according to EN 60721-3-6 | Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * | |
| — to mechanically active substances according to EN 60721-3-6 | Yes; Class 6S3 incl. sand, dust; * | |
| — Against mechanical environmental conditions acc. to EN 60721-3-6 | Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) | |
| Usage in industrial process technology | ||
| — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) | |
| — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) | |
| Remark | ||
| — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! | |
| Conformal coating | ||
| ● Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability | |
| ● Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection | |
| ● Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life | |
| ● Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A | |
| Dimensions | ||
| Width | 20 mm | |
| Height | 73 mm | |
| Depth | 58 mm | |
| Weights | ||
| Weight, approx. | 45 g | |
| Other | ||
| Data for selecting a current transformer | ||
| ● Burden power current transformer x/1A, min. | As a function of cable length and cross section, see device manual | |
| ● Burden power current transformer x/5A, min. | As a function of cable length and cross section, see device manual | |
| last modified: | 08/29/2020 | |
| Product | ||||||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 6AG1134-6PA20-7BD0 | |||||||||||||||||||||||||||||||||
| Product Description | SIPLUS ET 200SP AI EMETER 480VAC ST -40...+70°C with conformal coating based on 6ES7134-6PA20-0BD0 . Analog Input MODULE, AI ENERGY METER 480VAC ST, fits to BU-TYPE D0, CHANNEL DIAGNOSIS | |||||||||||||||||||||||||||||||||
| Product family | SIPLUS analog inputs | |||||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | |||||||||||||||||||||||||||||||||
| Price data | ||||||||||||||||||||||||||||||||||
| Price Group | 473 | |||||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | |||||||||||||||||||||||||||||||||
| Metal Factor | None | |||||||||||||||||||||||||||||||||
| Delivery information | ||||||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | |||||||||||||||||||||||||||||||||
| Standard lead time ex-works | 37 Day/Days | |||||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,054 Kg | |||||||||||||||||||||||||||||||||
| Product Dimensions (W x L x H) | Not available | |||||||||||||||||||||||||||||||||
| Packaging Dimension | 6,50 x 7,70 x 2,30 | |||||||||||||||||||||||||||||||||
| Package size unit of measure | CM | |||||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | |||||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | |||||||||||||||||||||||||||||||||
| Additional Product Information | ||||||||||||||||||||||||||||||||||
| EAN | 4047618085209 | |||||||||||||||||||||||||||||||||
| UPC | Not available | |||||||||||||||||||||||||||||||||
| Commodity Code | 90303900 | |||||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | A&DSE/SIP ADD | |||||||||||||||||||||||||||||||||
| Product Group | 4257 | |||||||||||||||||||||||||||||||||
| Group Code | R740 | |||||||||||||||||||||||||||||||||
| Country of origin | Germany | |||||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 18.07.2017 | |||||||||||||||||||||||||||||||||
| Product class | B: return restricted, please contact your Siemens partner/contact | |||||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | |||||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| |||||||||||||||||||||||||||||||||
| Classifications | ||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 6AG1134-6PA20-7BD0 EN_6AG1134-6PA20-7BD0.pdf | 145 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.