VAL-SEC-T2-48DC-P 2907877 PHOENIX CONTACT Type 2 surge protection plug View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-SEC-T2-48DC-P 2907877 PHOENIX CONTACT Type 2 surge protection plug

VAL-SEC-T2-48DC-P

2907877

PHOENIX_CONTACT

Product on demand only, returns will not be accepted.

Type 2 surge protection plug

Replacement connector for surge protection device from the VALVETRAB SEC product line for DC power sources.

More details


Earthing, lightning and surge protection > Accessories/spare parts for surge protection power supply systems

Trabtech (TT)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $108.27
Unit price: $108.27
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Key Commercial Data

Orderkey2907877
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 50 (C-4-2017)
GTIN4055626245027
Weight per Piece (excluding packing)49.600 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height46.4 mm
Width11.7 mm
Depth59.4 mm
Horizontal pitch0.6 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 6000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationII
T2
EN typeT2
IEC power supply systemDC
Mode of protection(DC+) - (DC-)
(DC+/DC-) - PE
Mounting typeon base element
Colorlight grey RAL 7035
Housing materialPA 6.6-FR 20% GF
PBT-FR
Degree of pollution2
Flammability rating according to UL 94V-0
TypeMale
Number of positions1
Surge protection fault messageoptical

Protective circuit

Nominal voltage UN48 V DC ... 60 V DC
Maximum continuous voltage UC75 V DC
Residual current IPE≤ 50 µA DC
Nominal discharge current In(8/20) µs20 kA
Maximum discharge current Imax(8/20) µs40 kA
Impulse discharge current (10/350) µs, charge2 As
Impulse discharge current (10/350) µs, specific energy4 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp4 kA
Short-circuit current rating ISCCR0.2 kA (without backup fuse)
6 kA (for 20 A gG/B backup fuse)
Voltage protection level Up≤ 0.5 kV
Residual voltage Ures≤ 0.5 kV (at In)
≤ 0.4 kV (at 10 kA)
≤ 0.35 kV (at 5 kA)
≤ 0.3 kV (at 2 kA)
TOV behavior at UT87 V DC (5 s / withstand mode)
Response time tA≤ 25 ns
Max. backup fuse with V-type through wiring20 A (gG / B at ISCCR> 200 A)
Max. backup fuse with branch wiring20 A (gG / B at ISCCR> 200 A)

Connection data

Connection methodpluggable

UL specifications

SPD Type1CA
Maximum continuous operating voltage MCOV75 V DC
Nominal voltage48 V DC
Mode of protection(DC+) - G
(DC-) - G
Power distribution systemDC
Voltage protection rating VPR400 V
Nominal discharge current In20 kA
Short-circuit current rating (SCCR)50 kA

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN .pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.