SWIRE-PF 107029 EATON ELECTRIC SWD feeder module, 24 V DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SWIRE-PF 107029 EATON ELECTRIC SWD feeder module, 24 V DC

SWIRE-PF

107029

EATON-MOELLER

SWD feeder module, 24 V DC

More details


PLC's > Fieldbus, decentr. periphery - power supply/segment module

Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



SWD feeder module, 24 V DC
Eaton Catalog No.
SWIRE-PF
EL-Nummer (Norway)
0004131951
Feed-in module for SWARE system for feed-in contactor control voltage
[

Delivery program

Subrange
Module
Basic function
Connection system SmartWire
Description
Power module for suppling the control voltage.
- Connection on SmartWire Gateway as interactive station (no address).
Notes

Max. 4 power modules per SmartWire chain.

,

Technical data

General
StandardsGeneral
IEC/EN 60947
EN 55011
EN 55022
IEC/EN 61000-4
IEC/EN 60068-2-27
Mounting
Top-hat rail IEC/EN 60715 (35mm) or screw fixing with fixing brackets ZB4-101-GF1 (accessories)
Dimensions (W x H x D)
35 x 90 x 74 mm
Weight
0.1 kg
Terminal capacities
Solid
0.34…1.5 mm2
Flexible with ferrule
0.34…1.5 mm2
Solid or stranded
22…16 AWG
Standard screwdriver
3.5 x 0.8 mm
Max. tightening torque
0.6 Nm
Climatic environmental conditions
Ambient temperatureOperation
-25 - +55 °C
Ambient temperatureStorage
- 25 - + 70 °C
Condensation
Take appropriate measures to prevent condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Air pressure (operation)
795 - 1080 hPa
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Overvoltage category/pollution degree
2
Mounting position
Vertical
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)Air discharge
8 kV
Electromagnetic fields (IEC/EN 61000-4-3, RFI) [V/m]
10
Radio interference suppression EN 55011, EN 55022
Class A
Burst Impulse (IEC/EN 61000-4-4, Level 3)Supply cable
2 kV
Burst Impulse (IEC/EN 61000-4-4, Level 3)Signal lines
2 kV
power pulses (surge) (IEC/EN 61000-4-5, level 2)
0.5 (supply cables, symmetrical) kV
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
10 V
Insulation resistance
Clearance in air and creepage distances
EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142
Insulation resistance
EN 50178, EN 60947-1
Voltage supply, Gateway electronic and SmartWire station electronics UGateway
Admissible range
20.4…28.8
Heat dissipation at 24 V DC
typically 1 W
Power supply UAUX(power supply for switching SmartWire elements e.g. contactor coils)
Rated operational voltage UAux
24, -15 %, +20 % (Derating from > 40 °C) V DC
Admissible range
20.4…28.8, at 45 °C: 21…28.8, at 50 °C: 21.6…28.8, at 55 °C: 22.2…27.6 V DC
Input current UAUXbei 24 V DC
Normally 3 A
Residual ripple
≦ 5 %
Voltage dips (IEC/EN 61131-2)
10 ms
Voltage [Us]
Yes V
Short-circuit protection, SmartWire side
no, external fuse 3 A or FAZ-Z3
LEDs
Power supply SmartWire contactors
UAux: green
MODBUS
Potential isolationTo SmartWire
to supply voltage UAUX: no
to supply voltage UGateway: no
SmartWire
Connection types
Plug, 6-pole
Data/power cable
6 core flat-band cable
maximum cable length System SmartWire
4 m
Bus termination
Connector plug
Station address
keine
Station
Max. 4 SmartWire modules per rung.
Address allocation
none
Function
none SmartWire module
Relay outputs
Overvoltage category/pollution degree
II/2
Conventional thermal current [Ith]
4 A
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
1 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+55 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - power supply/segment module (EC001600)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - feed and segment module ([email protected] [BAA071013])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
20.4 - 28.8 V
Voltage type of supply voltage
DC
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
2
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
With potential separation
No
With power supply module
Yes
Suitable as segment module
Yes
Remote module
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
No
Rail mounting possible
Yes
Wall mounting/direct mounting
Yes
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
Yes
Category according to EN 954-1
4
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
35 mm
Height
90 mm
Depth
74 mm
,

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
2252-01
North America Certification
UL listed, CSA certified
Specially designed for North America
No
,

Dimensions

SWIRE-PF
]

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN.pdf 51 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.