ANUNCIAR
DILM185-XP1 208292 Y7-208292 EATON ELECTRIC Paralleling link, for DILM185, (2 off) View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM185-XP1 208292 Y7-208292 EATON ELECTRIC Paralleling link, for DILM185, (2 off)

DILM185-XP1

208292

Y7-208292

EATON-MOELLER

Paralleling link, for DILM185, (2 off)

DILM185-XP1

Eaton Moeller® series DILM Paralleling link, for DILM185, (2 off)

Paralleling link, Product range: Accessories, Wiring accessories, For use with: DILM185A

More details


Low-voltage industrial components > Accessories/spare parts for low-voltage switch technology

Contactors more than 170 A

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $235.58
Unit price: $235.58
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series DILM paralleling link
Catalog Number
208292
Model Code
DILM185-XP1
EAN
4015082082925
Product Length/Depth
60 mm
Product Height
80 mm
Product Width
120 mm
Product Weight
1.45 kg
Compliances
CE
Catalog Notes
AC1 current carrying capacity of the open contactor increases by a factor of 2.5

General

Accessory/spare part type
Connecting bridge
Fitted with:
Cover for busbar tag shroud
Product category
Accessories
Protection
Protected against accidental contact in accordance to VDE 0106 part 100

Climatic environmental conditions

Ambient operating temperature - min
-40 °C
Ambient operating temperature - max
60 °C

Terminal capacities

Terminal capacity
2 x (0.75 - 2.5) mm², flexible with ferrule
2 x (0.75 - 4) mm², solid, Control circuit cables
2 x (20 x 32 x 0.5) mm (Number of segments x width x thickness), Flat conductor
1 x (0.75 - 2.5) mm², flexible with ferrule
2 x (11 x 21 x 1) mm (Number of segments x width x thickness), Flat conductor
1 x (0.75 - 4) mm², solid
1 x (6 x 16 x 0.8) mm (Number of segments x width x thickness), Flat conductor
Screw size
5 mm AF, Hexagon socket-head spanner, Terminal screw
Tightening torque
6 Nm, Screw terminal

Conventional thermal current Ith

Conventional thermal current ith of main contacts (1-pole, open)
700 A

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 208292 Low-voltage industrial controls and switchgear (EC002498)
Feature Name Feature Value
Type of accessory/spare part (EF000215) Connecting bridge
Accessory (EF013236) Yes
Spare part (EF013237) No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.