O controlador in-line oferece a possibilidade de se comunicar via PROFINET e Modbus / TCP. A programação é feita com PC Worx ou PC Worx Express (IEC 61131-3).
Sistemas de controle
* Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
The ILC 191 ETH 2TX modular small-scale controller for the Inline I/O system is at the heart of Easy Automation. The ILC 1X1 series is characterized by its support for the Modbus/TCP and PROFINET Ethernet-based protocols. A new feature is the support for an optional SD card.
Width | 80 mm |
---|---|
Height | 119.8 mm |
Depth | 71.5 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 55 °C |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Programming tool | PC WORX / PC WORX EXPRESS |
---|---|
Diagnostics tool | DIAG+ |
Configuration tool | Config+ Version 1.01 or later |
Weight | 285 g |
---|---|
Diagnostics display | No |
Controller redundancy | No |
Interface | INTERBUS local bus (master) |
---|---|
Connection method | Inline data jumper |
Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
Interface | Parameterization/operation/diagnostics |
Connection method | RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) |
Transmission speed | max. 115,2 kBit/s |
Interface | Ethernet 10Base-T/100Base-TX |
Connection method | RJ45 socket |
Transmission speed | 10/100 MBit/s |
Device function | PROFINET device |
---|
Typical current consumption | 210 mA |
---|---|
Max. current consumption | 870 mA (370 mA communications power + 500 mA analog voltage supply) |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC |
Residual ripple | ± 5 % |
Power dissipation | max. 5 W |
Amount of process data | max. 4096 Bit (INTERBUS) |
---|---|
max. 32768 Bit (internal Modbus Client) | |
Number of supported devices | max. 128 |
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Number of devices with parameter channel | max. 24 |
Number of supported branch terminals with remote bus branch | max. 3 |
Input name | Digital inputs |
---|---|
Number of inputs | 8 |
Connection method | Inline potential distributor |
Description of the input | EN 61131-2 type 1 NPN/PNP |
Output name | Digital outputs |
Number of outputs | 4 |
Connection method | 2, 3, 4-wire |
Maximum output current per channel | 500 mA |
Without analog input | yes |
Without analog output | yes |
Without pulse direction output | yes |
Without counter input | yes |
Programming tool | PC WORX / PC WORX EXPRESS |
---|---|
Program memory | 1 Mbyte (86 K instructions (IL)) |
Mass storage | 1 Mbyte |
Retentive mass storage | 48 kByte (NVRAM) |
Number of control tasks | 8 |
Realtime clock | Yes |
Título: | Tamanho: | Tipo: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2700976-ILC 191 ETH 2TX | 127 Kbytes |
Não há comentários do produto ainda.
Avaliação: | |
Nome: | |
Email: | |
Título: | |
Opinión: | |
Você recomendaria esse produto para comprar? | |
Adicionar avaliação |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.