Product successfully added to your shopping cart
ILC 191 ETH 2TX
2700976
PHOENIX_CONTACT
1
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3).
Control Systems (CST)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
The ILC 191 ETH 2TX modular small-scale controller for the Inline I/O system is at the heart of Easy Automation. The ILC 1X1 series is characterized by its support for the Modbus/TCP and PROFINET Ethernet-based protocols. A new feature is the support for an optional SD card.
Width | 80 mm |
---|---|
Height | 119.8 mm |
Depth | 71.5 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 55 °C |
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above mean sea level) |
Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
Vibration (operation) | 5g |
Programming tool | PC WORX / PC WORX EXPRESS |
---|---|
Diagnostics tool | DIAG+ |
Configuration tool | Config+ Version 1.01 or later |
Weight | 285 g |
---|---|
Diagnostics display | No |
Controller redundancy | No |
Interface | INTERBUS local bus (master) |
---|---|
Connection method | Inline data jumper |
Transmission speed | 500 kBaud / 2 MBaud (can be switched) |
Interface | Parameterization/operation/diagnostics |
Connection method | RS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45) |
Transmission speed | max. 115,2 kBit/s |
Interface | Ethernet 10Base-T/100Base-TX |
Connection method | RJ45 socket |
Transmission speed | 10/100 MBit/s |
Device function | PROFINET device |
---|
Typical current consumption | 210 mA |
---|---|
Max. current consumption | 870 mA (370 mA communications power + 500 mA analog voltage supply) |
Supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC |
Residual ripple | ± 5 % |
Power dissipation | max. 5 W |
Amount of process data | max. 4096 Bit (INTERBUS) |
---|---|
max. 32768 Bit (internal Modbus Client) | |
Number of supported devices | max. 128 |
Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Number of devices with parameter channel | max. 24 |
Number of supported branch terminals with remote bus branch | max. 3 |
Input name | Digital inputs |
---|---|
Number of inputs | 8 |
Connection method | Inline potential distributor |
Description of the input | EN 61131-2 type 1 NPN/PNP |
Output name | Digital outputs |
Number of outputs | 4 |
Connection method | 2, 3, 4-wire |
Maximum output current per channel | 500 mA |
Without analog input | yes |
Without analog output | yes |
Without pulse direction output | yes |
Without counter input | yes |
Programming tool | PC WORX / PC WORX EXPRESS |
---|---|
Program memory | 1 Mbyte (86 K instructions (IL)) |
Mass storage | 1 Mbyte |
Retentive mass storage | 48 kByte (NVRAM) |
Number of control tasks | 8 |
Realtime clock | Yes |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2700976-ILC 191 ETH 2TX | 127 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.