circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch

More details


Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Moulded Case Circuit Breakers 3VL SENTRON

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection

Value Unit
Rated voltage (EF003977) -V
Type of control element (EF006976) -
Rated permanent current Iu (EF001389) 1600.0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 70.0kA
Overload release current setting (EF002336) ['640', '1600']A
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']A
Adjustment range undelayed short-circuit release (EF007131) ['2000', '14400']A
Integrated earth fault protection (EF007296) false
Type of electrical connection of main circuit (EF006819) Other
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) true
DIN rail (top hat rail) mounting optional (EF008904) true
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) false
With under voltage release (EF007518) false
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Front side
Complete device with protection unit (EF008906) true
Motor drive integrated (EF006697) false
Motor drive optional (EF007386) true
Degree of protection (IP) (EF005474) IP20


circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch
Model
Type of the driving mechanism / motor driveNo
Design of the overcurrent releaseETU10
General technical data
number of poles3
Size of the circuit-breaker3VL8
Electrical endurance (switching cycles) / typical1 500
Usage categoryA
Performance class for circuit breakerN
Mechanical service life (switching cycles) / typical3 000
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750Q
Operating frequency / maximum30 1/s
Voltage
Rated operational voltage Ue / max.690 V
Insulation voltage
● rated value800 V
● at AC / rated value800 V
Surge voltage resistance / rated value8 kV
Operating voltage
● rated value / maximum690 V
● for main current circuit / at AC / at 50 Hz / maximum690 V
● for main current circuit / at AC / at 60 Hz / maximum690 V
Protection class
Protection class IPIP20
protection function of the overcurrent releaseLI
Current
Continuous current / rated value1 600 A
Derating temperature / for the rated value of the continuous current50 °C
adjustable pick-up value current
● of the current-dependent overload release / Full-scale value1 600 A
● of instantaneous short-circuit trip unit / initial value2 000 A
● of instantaneous short-circuit trip unit / Full-scale value14 400 A
Main circuit
Operating frequency
● 1 / rated value50 Hz
● 2 / rated value60 Hz
Operating current
● at 40 °C / rated value1 600 A
● at 50 °C / rated value1 600 A
● at 55 °C / rated value1 520 A
● at 60 °C / rated value1 520 A
● at 65 °C / rated value1 280 A
● at 70 °C / rated value1 280 A
Auxiliary circuit
Number of CO contacts / for auxiliary contacts0
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Suitability
suitability for usesystem protection
Adjustable parameters
adjustable pick-up value current / of the current-dependent overload release / initial value640 A
Product details
Product component
● Trip indicatorNo
● Auxiliary switchNo
● Voltage triggerNo
● undervoltage releaseNo
● undervoltage release with leading contactNo
Product extension / optional / motor driveYes
Product function
Product function
● of thermal overload trip unitadjustable
● Ground fault protectionNo
● for neutral conductors / Short-circuit and overload proofNo
● Overload protectionYes
Short circuit
Operational short-circuit current breaking capacity (Ics)
● at 240 V / rated value50 kA
● at 415 V / rated value35 kA
● at 500 V / rated value30 kA
● at 690 V / rated value15 kA
Maximum short-circuit current breaking capacity (Icu)
● at 240 V / rated value100 kA
● at 415 V / rated value70 kA
● at 440 V / rated value50 kA
● at 480 V / acc. to NEMA / rated value50 kA
● at 500 V / rated value40 kA
● at 600 V / acc. to NEMA / rated value30 kA
● at 690 V / rated value30 kA
Connections
Arrangement of electrical connectors / for main current circuitfront side
Type of connectable conductor cross-sections / for auxiliary contacts
● solid0.75 ... 1.5 mm²
● finely stranded / with core end processing0,75 ... 1.0 mm²
Type of electrical connection / for main current circuitwithout connection accessoires
Mechanical Design
Height406.5 mm
Width228.5 mm
Depth333.5 mm
Mounting typefixed mounting
Environmental conditions
Ambient temperature / during operation
● minimum-25 °C
● maximum70 °C
Ambient temperature / during storage
● minimum-40 °C
● maximum80 °C
Certificates
certificate of suitabilityIEC, high switching capacity (H)
● reference code / acc. to DIN EN 61346-2Q
General Product ApprovalEMCTest CertificatesShipping Approval

CCC

Miscellaneous

TSE

C-TICK

Special Test Certificate

RINA / Registro Italiano Navale

Shipping Approvalother

RMRS / Russian Maritime Register

Environmental Confirmations

Miscellaneous

Confirmation

Manufacturer Declaration

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications


Product
Article Number (Market Facing Number)3VL8716-2SB30-0AA0
Product Descriptioncircuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU10, LI In=1600A, rated current IR=640...1600A, overload protection, II=1.25 to 9 xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch
Product familyNot available
Product Lifecycle (PLM)PM400:Phase Out Started
PLM Effective DateProduct phase-out since: 01.10.2019
Notes
Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
Price data
Price Group12N
Surcharge for Raw MaterialsNone
Metal FactorLAP-----
Delivery information
Export Control RegulationsECCN : EAR99 / AL : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)33,400 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension300,00 x 600,00 x 250,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209826748
UPCNot available
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10.1
Product Group3740
Group CodeP360
Country of originMexico
Compliance with the substance restrictions according to RoHS directiveSince: 01.07.2006
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationNo
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-04-09
eClass7.127-37-04-09
eClass827-37-04-09
eClass927-37-04-09
eClass9.127-37-04-09
ETIM4EC000228
ETIM5EC000228
ETIM6EC000228
ETIM7EC000228
UNSPSC1439-12-16-01
UNSPSC1539-12-16-01

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.