Moulded Case Circuit Breakers 3VL SENTRON

Moulded Case Circuit Breakers (MCCBs) from the 3VL SENTRON series are high-performance protective devices designed for industrial and commercial power distribution systems. These circuit breakers are available in 3-pole (3P) and 4-pole (4P) configurations, with rated currents ranging from 160 A to 630 A, and breaking capacities up to 50 kA at 41...

Moulded Case Circuit Breakers (MCCBs) from the 3VL SENTRON series are high-performance protective devices designed for industrial and commercial power distribution systems. These circuit breakers are available in 3-pole (3P) and 4-pole (4P) configurations, with rated currents ranging from 160 A to 630 A, and breaking capacities up to 50 kA at 415 V AC. They feature electronic or thermal-magnetic trip units for precise overload and short-circuit protection, adjustable settings for current and time delays, and a compact design suitable for fixed or plug-in mounting. The 3VL series supports a wide range of accessories, including auxiliary contacts, shunt trips, undervoltage releases, and motor operators, enabling seamless integration into automation systems. With a rated insulation voltage of 690 V and compliance with IEC 60947-2, these MCCBs ensure reliable operation in demanding environments.

These MCCBs are primarily used in main distribution boards, sub-distribution panels, and motor control centers within industrial plants, commercial buildings, and infrastructure projects. They are ideal for protecting feeders, transformers, capacitors, and large motors in sectors such as manufacturing, energy, water treatment, and data centers. The 3VL series is also suitable for generator protection and backup power systems, where high breaking capacity and selectivity are critical. Their modular design allows for easy installation in switchgear cabinets, and the optional communication modules enable remote monitoring via fieldbus systems like PROFIBUS or Modbus.

The 3VL SENTRON series includes several subcategories based on frame size and breaking capacity. Key article codes include 3VL160 (160 A frame), 3VL250 (250 A frame), 3VL400 (400 A frame), and 3VL630 (630 A frame). The code structure typically follows the pattern 3VLXXXX-XXXXX, where the first digits indicate the frame size and rated current, and the suffix defines the trip unit type, number of poles, and accessories. For example, 3VL160-1DC33-0AA0 represents a 160 A, 3P, thermal-magnetic MCCB. Other variants include 3VL250-1DC33-0AA0 and 3VL400-1DC33-0AA0, each offering different breaking capacities and trip characteristics.

At Electric Automation Network, we provide the full 3VL SENTRON range with real-time pricing and express worldwide shipping. Our team of specialized engineers offers personalized technical support, including trip unit selection, coordination studies, and accessory configuration. Each product listing includes detailed technical documentation, wiring diagrams, and compliance certificates. Whether you need a standard MCCB or a customized solution for a critical application, we ensure fast delivery and expert guidance to optimize your power distribution system.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

3VL4731-3UJ46-0AA0

3VL4731-3UJ46-0AA0

-

circuit breaker VL400L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL9400-8CA30

3VL9400-8CA30

-

accessory for VL400, terminal cover IP30 extended comprises 2 covers 3-pole

3 View Availability View Price

3VL3725-3TA43-0AA0

3VL3725-3TA43-0AA0

-

circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release with box terminal without auxiliary/alarm switch

3 View Availability View Price

3VL2706-3TB43-0AA0

3VL2706-3TB43-0AA0

-

circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3720-2TF46-0AA0

3VL3720-2TF46-0AA0

-

circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU20, LSI In=200A, rated current IR=80...200A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL1702-1DA33-0AA0

3VL1702-1DA33-0AA0

-

circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=20A, rated current II=300A, short-circuit prot. without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL4731-3MG36-0AA0

3VL4731-3MG36-0AA0

-

CIRCUIT-BREAKER VL 400L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT ETU22, LSIG 3PHASES/3WIRES IN=315A, RATED CURRENT IR=128-315A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE ETU COMMUNICATION-CAPABLE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL3720-2NE46-0AA0

3VL3720-2NE46-0AA0

-

circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU20, LSI In=200A, rated current IR=80...200A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch

3 View Availability View Price

3VL9200-4PD30

3VL9200-4PD30

-

accessory for VL160, plug-in base assembly kit front connection RCD module (RCD) 3-pole

3 View Availability View Price

3VL1705-1DA36-0AA0

3VL1705-1DA36-0AA0

-

circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=50A, rated current Ir=50A, overload protection II=600A, short-circuit prot. with screw terminals without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3110-3PH30-0AA0

3VL3110-3PH30-0AA0

-

CIRCUIT-BREAKER VL 250 UL; TYP FG (CAT NO. LFX3V100) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 100A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 40-100A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL6780-2ME36-0AA0

3VL6780-2ME36-0AA0

-

circuit breaker VL800H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU20, LSI In=800A, rated current IR=320...800A, overload protection, ISD=1.5 to 7 xIR, II=8 xIN short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch

3 View Availability View Price

3VL4140-1VM30-0AA0

3VL4140-1VM30-0AA0

-

CIRCUIT-BREAKER VL 400 UL TYP JG (CAT NO. NJX3G400) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V AND 25KA/600V (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN=400A, RATED CURRENT SHORT-CIRCUIT PROTECTION SHORT-CIRCUIT PROTECTION IR=150-400A OVERCURRENT REL. F. PLANT PROTECTION WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL4731-1NB46-0AA0

3VL4731-1NB46-0AA0

-

CIRCUIT-BREAKER VL 400N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT ETU10, LI IN=315A, RATED CURRENT IR=128-315A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE ETU COMMUNICATION-CAPABLE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL7180-1PB30-0AA0

3VL7180-1PB30-0AA0

-

CIRCUIT-BREAKER VL 1200 UL; TYP NG (CAT NO. NNX3R800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LI TU= 40 DEGR. CELSIUS IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL2505-3KN30-0AA0

3VL2505-3KN30-0AA0

-

CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. LDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 VERY HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 100KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL2710-1NA46-0AA0

3VL2710-1NA46-0AA0

-

circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LIN In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected with screw terminals without auxiliary release ETU communication-capable without auxiliary/alarm switch

3 View Availability View Price

3VL9400-3MS00

3VL9400-3MS00

-

accessory for VL400, mot. op. mech. w/ strd en. mech 60V AC/DC

3 View Availability View Price

3VL8716-2SH30-0AA0

3VL8716-2SH30-0AA0

-

circuit breaker VL1600H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/4 lines with connecting cable In=1600A, rated current IR=640...1600A, overload protection, ISD=1.5 to 8xIR, II=9XIN short-circuit protection without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3525-3VJ30-0AA0

3VL3525-3VJ30-0AA0

-

CIRCUIT-BREAKER VL 250 UL TYPE FG (CAT NO. LFK3K250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG-G WITH ALARM TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN=250A, RATED CURRENT ISD=1,25-10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR=70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL3725-1UL36-0AA0

3VL3725-1UL36-0AA0

-

circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit LCD ETU42, LSIG 3 phases/3 lines In=250A, rated current IR=100...250A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL2716-2EM46-0AA0

3VL2716-2EM46-0AA0

-

circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection N protected with screw terminals without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL7712-1UL36-0AA0

3VL7712-1UL36-0AA0

-

circuit breaker VL1250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit LCD ETU42, LSIG 3 phases/3 lines In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3725-2MP33-0AA0

3VL3725-2MP33-0AA0

-

circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release with box terminal ETU communication-capable without auxiliary/alarm switch

3 View Availability View Price

3VL1705-2EH46-0AA0

3VL1705-2EH46-0AA0

-

circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection Electronic Trip Unit TM, LI In=50A, rated current Ir=50A, overload protection II=600A, short-circuit prot. N unprotected with screw terminals without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3525-2PB30-0AA0

3VL3525-2PB30-0AA0

-

CIRCUIT-BREAKER VL 250 UL TYPE FG (CAT NO. HFK3R250) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN=250A, RATED CURRENT II= 1.25-11 X IN, SHORT-CIRCUIT PROTECTION IR=70-250A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL7180-1PD30-0AA0

3VL7180-1PD30-0AA0

-

CIRCUIT-BREAKER VL 1200 UL; TYP NG (CAT NO. NNX3W800) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD BREAKING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) ELECTRONIC TRIP UNIT ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 800A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 300-800A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH

3 View Availability View Price

3VL9112-5GA40

3VL9112-5GA40

-

accessory for VL160X, RCD module, mounting on bottom In=160A Ue=127...480V 4-pole

3 View Availability View Price

3VL2710-3EE43-0AA0

3VL2710-3EE43-0AA0

-

circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 4-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=100A, rated current II=2500A, short-circuit protection without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

3VL3725-1DE33-0AA0

3VL3725-1DE33-0AA0

-

circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=250A, rated current II=3500A, short-circuit protection, with box terminal without auxiliary release without auxiliary/alarm switch

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.