Viewed products

POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR

Power distribution and low voltage switchgear form the backbone of any electrical installation, from industrial plants to commercial buildings. This category encompasses devices designed to safely distribute electrical energy, protect circuits against overloads and short circuits, and ensure operational continuity. Key components include molded ...

Power distribution and low voltage switchgear form the backbone of any electrical installation, from industrial plants to commercial buildings. This category encompasses devices designed to safely distribute electrical energy, protect circuits against overloads and short circuits, and ensure operational continuity. Key components include molded case circuit breakers (MCCBs), air circuit breakers (ACBs), switch disconnectors, and distribution panels. These units are characterized by parameters such as rated current (from 16A to 6300A), number of poles (3P, 4P), breaking capacity (up to 150kA at 415V AC), and rated operational voltage (up to 690V AC). They are available in fixed or withdrawable versions, with options for motor operators, shunt trips, and auxiliary contacts. The equipment complies with international standards like IEC 60947-2 and IEC 61439, ensuring reliability and safety in power management.

Applications span across main distribution boards (MDBs), sub-distribution boards, motor control centers (MCCs), and critical infrastructure such as data centers, hospitals, and renewable energy plants. In industrial settings, these switchgears manage power for heavy machinery, conveyor systems, and process automation. In commercial buildings, they feed lighting, HVAC, and elevator systems. They are also essential in utility substations and transformer stations, where they provide overcurrent protection and isolation. The robust design, often with IP54 or higher enclosures, allows installation in harsh environments like chemical plants or offshore platforms.

This category includes subcategories such as molded case circuit breakers (e.g., series like Tmax, NZM, or SACE), air circuit breakers (e.g., Emax or Masterpact), switch disconnectors (e.g., OT series), and distribution panels (e.g., Prisma or Sivacon). Typical article codes follow patterns like 'SI05-MCCB-160A-3P' for a 160A three-pole MCCB or 'SI05-ACB-2000A-4P' for a 2000A four-pole ACB. Other key items include fuse switch disconnectors, changeover switches, and busbar trunking systems. Each product is specified with detailed technical data sheets covering electrical ratings, dimensions, and accessories.

Partnering with Electric Automation Network ensures access to genuine, certified products with real-time pricing and global express shipping. Our engineering team provides personalized technical support for selection, coordination studies, and compliance with local regulations. We offer comprehensive documentation, including wiring diagrams and test certificates, to streamline your project execution. Whether you need a single MCCB for a retrofit or a full switchgear lineup for a new plant, we deliver with speed and expertise.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

3VA1340-6EF42-0AA0

3VA1340-6EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 4-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In neutral unprotected flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1325-5MH32-0AA0

3VA1325-5MH32-0AA0

-

circuit breaker 3VA1 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=250A without overload protection short-circuit protection Ii=8...16 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 3 poles, starter protection TM120M, AM, In=250 A without overload protection short circuit protection Ii=8...16 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1325-6MH32-0AA0

3VA1325-6MH32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 3-pole, starter protection TM120M, AM, In=250 A without overload protection short-circuit protection Ii=8...16 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 3 poles, starter protection TM120M, AM, In=250 A without overload protection short circuit protection Ii=8...16 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1325-7MH32-0AA0

3VA1325-7MH32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class C Icu=110 kA @ 415 V 3-pole, starter protection TM120M, AM, In=250 A without overload protection short-circuit protection Ii=8...16 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class C Icu=110 kA @ 415 V 3 poles, starter protection TM120M, AM, In=250 A without overload protection, short circuit protection Ii=8...16 x In, flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-4EF32-0AA0

3VA1332-4EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 3-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 3 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-4EF42-0AA0

3VA1332-4EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral unprotected flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-4FF42-0AA0

3VA1332-4FF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class N Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 50% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class N Icu=36 kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 50% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-4GF42-0AA0

3VA1332-4GF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 100% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 100% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-5EF32-0AA0

3VA1332-5EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 3 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In flat connection with screws. Cancelations and returns limited. Consult conditions.

3 View Availability View Price

3VA1332-5EF42-0AA0

3VA1332-5EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral unprotected flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-5FF42-0AA0

3VA1332-5FF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=55 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 50% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=55kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 50% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-5GF42-0AA0

3VA1332-5GF42-0AA0

-

circuit breaker 3VA1 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM240, ATAM, In=320A overload protection Ir=224A...320A short-circuit protection Ii=5...10 x In N conductor protection 100% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 4 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 100% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-5MH32-0AA0

3VA1332-5MH32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 3-pole, starter protection TM120M, AM, In=320 A without overload protection short-circuit protection Ii=7...14 x In nut keeper kit

Automatic switch 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 3 poles, starter protection TM120M, AM, In=320 A without overload protection short circuit protection Ii=8...16 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-6EF32-0AA0

3VA1332-6EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 3-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 3 poles, distribution protection TM240, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-6EF42-0AA0

3VA1332-6EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral unprotected flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-6FF42-0AA0

3VA1332-6FF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 50% nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 50% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-6GF42-0AA0

3VA1332-6GF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 100% nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224A... 320A short circuit protection Ii=5...10 x In neutral protection 100% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-6MH32-0AA0

3VA1332-6MH32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class H Icu=70 kA @ 415 V 3-pole, starter protection TM120M, AM, In=320 A without overload protection short-circuit protection Ii=7...14 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class H Icu=70kA @ 415V 3 poles, starter protection TM120M, AM, In=320 A without overload protection short circuit protection Ii=8...16 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-7EF32-0AA0

3VA1332-7EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class C Icu=110 kA @ 415 V 3-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class C Icu=110 kA @ 415 V 3 poles, prot. distributions TM240, ATAM, In=320 A overload protection Ir=224 A ... 320 A short circuit protection Ii=5...10 x In flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-7EF42-0AA0

3VA1332-7EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class C Icu=110 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class C Icu=110 kA @ 415 V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224 A ... 320 A short circuit protection Ii=5...10 x In neutral not protected, flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-7FF42-0AA0

3VA1332-7FF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class C Icu=110 kA @ 415 V 4-pole, line protection TM240, ATAM, In=320 A overload protection Ir=224 A...320 A short-circuit protection Ii=5...10 x In neutral conductor protection 0.5 nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class C Icu=110 kA @ 415 V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224 A ... 320 A short circuit protection Ii=5...10 x In, neutral protected 0.5, flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-7GF42-0AA0

3VA1332-7GF42-0AA0

-

circuit breaker 3VA1 IEC frame 400 breaking capacity class C Icu=110kA @ 415 V 4-pole, line protection TM240, ATAM, In=320A overload protection Ir=224A ...320A short-circuit protection Ii=5...10 x In N conductor protection 1 nut keeper kit

3VA1 IEC circuit breaker, size 400. Cutting power class C Icu=110 kA @ 415 V 4 poles, TM240 distribution protection, ATAM, In=320 A overload protection Ir=224 A ... 320 A short circuit protection Ii=5...10 x In. Neutral protected 1, flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1332-7MH32-0AA0

3VA1332-7MH32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class C Icu=110 kA @ 415 V 3-pole, starter protection TM120M, AM, In=320 A without overload protection short-circuit protection Ii=7...14 x In nut keeper kit

3VA1 IEC circuit breaker, size 400, cutting power class C Icu=110 kA @ 415 V 3 poles, TM120M starter protection, AM, In=320 A without overload protection, short circuit protection Ii=8...16 x In, flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-1AA32-0AA0

3VA1340-1AA32-0AA0

-

switch disconnector 3VA1 IEC frame 400 3-pole SD100, In=400A without overload protection w/o short-circuit protection nut keeper kit

Switch-disconnector 3VA1 IEC size 400 3 poles SD100, In=400 A without overload protection without short circuit protection flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-1AA42-0AA0

3VA1340-1AA42-0AA0

-

switch disconnector 3VA1 IEC frame 400 4-pole SD100, In=400A without overload protection w/o short-circuit protection nut keeper kit

Switch-disconnector 3VA1 IEC size 400 4 poles SD100, In=400 A without overload protection without short circuit protection flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-4EF32-0AA0

3VA1340-4EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 3-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 3 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In flat connection with screws. Cancelations and returns limited. Consult conditions.

3 View Availability View Price

3VA1340-4EF42-0AA0

3VA1340-4EF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In N conductor unprotected nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In neutral unprotected flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-4FF42-0AA0

3VA1340-4FF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class N Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In neutral conductor protection 50% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class N Icu=36 kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In neutral protection 50% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-4GF42-0AA0

3VA1340-4GF42-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class S Icu=36 kA @ 415 V 4-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In neutral conductor protection 100% nut keeper kit

Circuit breaker 3VA1 IEC size 400 Cutting power class S Icu=36 kA @ 415V 4 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In neutral protection 100% flat connection with screws. Manufactured to order. Non-Cancelable Non-Returnable.

3 View Availability View Price

3VA1340-5EF32-0AA0

3VA1340-5EF32-0AA0

-

circuit breaker 3VA1 IEC Frame 400 breaking capacity class M Icu=55 kA @ 415 V 3-pole, line protection TM240, ATAM, In=400 A overload protection Ir=280 A...400 A short-circuit protection Ii=5...10 x In nut keeper kit

Circuit Breaker 3VA1 IEC size 400 Cutting power class M Icu=55kA @ 415V 3 poles, TM240 distribution protection, ATAM, In=400 A overload protection Ir=280A... 400A short circuit protection Ii=5...10 x In flat connection with screws. Cancelations and returns limited. Consult conditions.

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.

products sitemap