3UG5462-1AA40 SIEMENS DC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monit.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3UG5462-1AA40 SIEMENS DC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monit..

3UG5462-1AA40

SIEMENS

DC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operating hours counter, warning and alarm thresholds, automatic or manual reset, ON delay 0-999.0 sec, OFF delay 0-999.0 sec, automatic reclosing delay 0-999.0 sec Supply voltage: 24 V DC 1 changeover contact, screw terminal

DC load monitoring relay for PROFINET, max. 1 × 63 A DC, max. 800 V Width: 45.0 mm Overrun monitoring due to excess and default of current, voltage and power; energy consumption meter, regeneration meter, manoeuvring meter, operating hours counter, warning thresholds and alarm automatic or manual rearmament delay at start 0-999.0 s, delay at disconnection 0-999.0 s, delay at reconnection. 0-999.0 s Supply voltage: 24 V DC 1 switched, screw terminals

More details


CONTROL AND CONTACTORS > Function relays

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total price: $1,153.19
Unit price: $1,153.19

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

DC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operating hours counter, warning and alarm thresholds, automatic or manual reset, ON delay 0-999.0 sec, OFF delay 0-999.0 sec, automatic reclosing delay 0-999.0 sec Supply voltage: 24 V DC 1 changeover contact, screw terminal
product brand nameSIRIUS
product designationDC load monitoring relay
design of the productfor PROFINET
product type designation3UG5
General technical data
type of current for monitoringDC
product functionDC load monitoring relay
power loss [W] maximum3 W
insulation voltage
● for overvoltage category II according to IEC 60664 with degree of pollution 3 rated value600 V
● for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
● of the auxiliary and control circuit for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value30 V
type of voltage for monitoringDC
surge voltage resistance rated value8 kV
maximum permissible voltage for safe isolation
● between auxiliary and auxiliary circuit24 V
● between control and auxiliary circuit24 V
protection class IP
● on the frontIP20
● of the terminalIP00
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
mechanical service life (switching cycles) typical10 000 000
electrical endurance (switching cycles) for relay outputs maximum100 000
● note0.5 A 125 V AC, with resistive load up to 40 °C
thermal current of the switching element with contacts maximum1 A
certificate of suitabilityCE
reference code according to IEC 81346-2K
Substance Prohibitance (Date)05/31/2019
Product Function
product function
● overvoltage detection DCYes
● undervoltage detection DCYes
● overcurrent detection DCYes
● undercurrent detection DCYes
● auto-RESETYes
● manual RESETYes
Supply voltage
type of voltage of the supply voltageDC
supply voltage 1 at DC rated value24 V
operating range factor supply voltage rated value at DC0.85 ... 1.15
Measuring circuit
measurable current-63 ... +63 A
measurable voltage at DC0 ... 800 V
adjustable voltage range0 ... 800 V
adjustable current response value current
● 1-63 ... +63 A
adjustable response delay time
● when starting0 ... 999 s
● with lower or upper limit violation0 ... 999 s
response time maximum100 ms
relative temperature-related measurement deviation0.5 %
internal resistance of the measuring circuit10 mΩ
Communication/ Protocol
protocol is supported
● PROFINET IO protocolYes
● Address Resolution Protocol (ARP)Yes
design of the interface Fast Ethernet interfaceYes
number of interfaces according to PROFINET1
product function at the Ethernet interface AutocrossoverYes
interface design 1 RJ45 (Ethernet)Yes
product function at the 1st interface PROFINET IO deviceYes
number of ports at the 1st interface1
service for open IE communication LLDPYes
transmission mode for Industrial EthernetPROFINET with 100 Mbps full duplex (100BASE-TX)
PROFINET conformity classA
network load class according to PROFINET1
Auxiliary circuit
number of CO contacts for auxiliary contacts1
ampacity of the output relay at DC-13
● at 24 V1 A
ampacity for overcurrent duration < 1 s maximum permissible1 A
continuous current of the DIAZED fuse link of the output relay2 A
Electromagnetic compatibility
conducted interference
● due to burst according to IEC 61000-4-42 kV
● due to conductor-earth surge according to IEC 61000-4-52 kV
● due to conductor-conductor surge according to IEC 61000-4-51 kV
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Galvanic isolation
design of the electrical isolationProtective separation
galvanic isolation
● between input and outputYes
● between the voltage supply and other circuitsYes
Safety related data
electromagnetic compatibilityIEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
Connections/ Terminals
product component removable terminal for main circuitNo
product component removable terminal for auxiliary and control circuitYes
type of electrical connectionscrew-type terminals
type of connectable conductor cross-sections
● for main contacts
— solid2x (1 ... 16 mm²), 1x (1 ... 16 mm²)
— stranded2x (1 ... 16 mm²), 1x (1 ... 16 mm²)
— finely stranded with core end processing2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
● at AWG cables for main contacts1x (18 ... 1), 2x (18 ... 2)
type of connectable conductor cross-sections
● for auxiliary contacts
— solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
— finely stranded with core end processing2x (0,5 ... 1,5 mm²), 1x (0,5 ... 4 mm²)
● at AWG cables for auxiliary contacts1x (20 ... 12), 2x (20 ... 14)
tightening torque
● for main contacts with screw-type terminals3 ... 4.5 N·m
● for auxiliary contacts with screw-type terminals0.6 ... 0.8 N·m
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
height100 mm
width45 mm
depth141.6 mm
required spacing
● with side-by-side mounting
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side0 mm
● for grounded parts
— forwards0 mm
— backwards0 mm
— upwards50 mm
— at the side3 mm
— downwards50 mm
● for live parts
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side3 mm
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +80 °C
● during transport-40 ... +80 °C
Certificates/ approvals

Downloads and manuals

General Product ApprovalDeclaration of ConformityTest Certificatesother

Confirmation

UL

EAC

EC/EU-Declaration of Conformity

Type Test Certificates/Test Report

Declaration of Conformity

other

Confirmation

PROFIBUS-Certification

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Characteristic: Derating
last modified:1/12/2021
Date
5/4/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3UG5462-1AA40
Product DescriptionDC load monitoring relay for PROFINET, max. 1x63 A DC, max. 800 V Width: 45.0 mm Monitoring for violation of upper and lower limit of current, voltage and power; Energy consumption counter, energy recovery counter, switching cycle counter, operating hours counter, warning and alarm thresholds, automatic or manual reset, ON delay 0-999.0 sec, OFF delay 0-999.0 sec, automatic reclosing delay 0-999.0 sec Supply voltage: 24 V DC 1 changeover contact, screw terminal
Product familyDC load monitoring
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group41H / 41H
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsAL : N / ECCN : EAR99
Standard lead time ex-works20 Day/Days
Net Weight (kg)0,385 Kg
Packaging Dimension110,00 x 175,00 x 70,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621064727
UPC804766977251
Commodity Code85364900
LKZ_FDB/ CatalogIDCC-IC10
Product Group4K62
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 31.05.2019
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-92-08
eClass7.127-37-92-08
eClass827-37-92-08
eClass927-37-16-92
eClass9.127-37-16-92
ETIM5EC002586
ETIM6EC002586
ETIM7EC002586
ETIM8EC002586

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.