PV-SET 1000 DC 2804445 PHOENIX CONTACT Surge protection device set View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PV-SET 1000 DC 2804445 PHOENIX CONTACT Surge protection device set

PV-SET 1000 DC

2804445

PHOENIX_CONTACT

Surge protection device set

Surge protection in IP65 housing for single string photovoltaic systems up to 1000 V DC, connection via SUNCLIX male/female connector.

More details


Home > PHOENIX CONTACT

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete.

Go to successor article: SOL-SC-1ST-0-DC-1MPPT-2001 2403338

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
IEC test classificationPV T2
TypeInstallation housing
Distance between live and grounded parts8 mm
Number of positions2
Surge protection fault messageoptical
Insulation characteristics
Protection classII
Overvoltage categoryIII
Pollution degree2

Electrical properties
Nominal current IN25 A DC
Indicator/remote signaling
Switching functionChangeover contact, 1-pos.
Operating voltage5 V AC ... 250 V AC
30 V DC
Operating current5 mA AC ... 1.5 A
1.5 A DC

Connection data
PE
Connection methodScrew terminal blocks
Screw threadM5
Tightening torque, min4.5 Nm
Tightening torque4.5 Nm ... 30 lbf-in. (UL)
Stripping length16 mm
Connection methodMC 1,5/3
Screw threadM2
Tightening torque, min0.25 Nm
Tightening torque2 lbf-in. ... 4 lbf-in.
Stripping length7 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section, rigid min.0.14 mm²
Conductor cross section, rigid max.1.5 mm²

Dimensions
Dimensional drawingvrgewjuehj.jpg
Width125 mm
Height200 mm
Depth122 mm
Horizontal pitch5 Div.

Material specifications
Flammability rating according to UL 94V2 (Gehäuse / Deckel)
V0 (Steckverbinder)
Cover materialPolycarbonate, transparent
Housing materialPolycarbonate, glass-fiber-reinforced
Connector materialPA

Protective circuit
Direction of action(L+)-PE & (L-)-PE & (L+)-(L-)
Maximum continuous voltage UC1000 V DC
Rated load current IL≤ 80 A DC
Residual current IPE≤ 20 µA
≤ 250 µA AC
Standby power consumption PC≤ 20 mW
Nominal discharge current In(8/20) µs (L+) - (L-)15 kA
Nominal discharge current In(8/20) µs (L-) - PE15 kA
Maximum discharge current Imax(8/20) µs (L+) - (L-)40 kA
Total discharge current Itotal(8/20) µs40 kA
Voltage protection level Up(L+) - (L-)≤ 3.7 kV
Voltage protection level Up(L+) - PE≤ 3.7 kV
Voltage protection level Up(L-) - PE≤ 3.7 kV
Residual voltage Ures(L+) - (L-)≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Residual voltage Ures(L+) - PE≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Residual voltage Ures(L-) - PE≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Response time tA(L+) - (L-)≤ 25 ns
Response time tA(L+) - PE≤ 25 ns
Response time tA(L-) - PE≤ 25 ns
Max. backup fuse with branch wiringnot required
Protective circuit DC voltage side (DC)
Rated surge voltage resistance Uimp6 kV
Short-circuit current ISCSTC25 A DC
Open circuit voltage UOCSTC830 V DC (Solar generator)
Maximum discharge current Imax(8/20) µs (L+) - (L-)40 kA
Maximum discharge current Imax(8/20) µs (L-) - PE40 kA
Maximum discharge current Imax(8/20) µs (L+) - PE40 kA
Response time tA(L+) - (L-)≤ 25 ns
Response time tA(L+) - PE≤ 25 ns
Response time tA(L-) - PE≤ 25 ns
Recommended backup fuse maximumnot required
Total discharge current Itotal(8/20) µs40 kA
Insulation resistance Riso> 5 GΩ (at 500 V DC)
Max. backup fuse with branch wiringnot required
Nominal discharge current In(8/20) µs (L+) - (L-)15 kA
Nominal discharge current In(8/20) µs (L+) - PE15 kA
Nominal discharge current In(8/20) µs (L-) - PE15 kA
Rated load current IL≤ 80 A DC
Residual voltage Ures(L+) - (L-)≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Residual voltage Ures(L+) - PE≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Residual voltage Ures(L-) - PE≤ 3.7 kV (at In)
≤ 3.1 kV (at 5 kA)
≤ 3.5 kV (at 10 kA)
≤ 4 kV (at 20 kA)
≤ 4.6 kV (at 30 kA)
≤ 5 kV (at 40 kA)
Residual current IPE≤ 20 µA
≤ 250 µA AC
Voltage protection level Up(L+) - (L-)≤ 3.7 kV
Voltage protection level Up(L+) - PE≤ 3.7 kV
Voltage protection level Up(L-) - PE≤ 3.7 kV
Standby power consumption PC≤ 20 mW

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP65
Impact strengthIK08
Ambient conditionsA, B
Ambient temperature (operation)-30 °C ... 55 °C

Standards and regulations
Air clearances and creepage distances
Standards/regulationsEN 50539-11
Standards/specificationsIEC 61439-2
Note2011
Standards/specificationsEN 61439-2
Note2011
Standards/specificationsEN 50539-11
NoteSurge protection

Mounting
Mounting typeSurface/Wall mounting

Datasheet - PDF

Title: Size: Type:
PHOENIX CONTACT-2804445-PV-SET 1000 DC 119 Kbytes   PHOENIX CONTACT-2804445-PV-SET 1000 DC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.