Produto adicionado com sucesso ao seu carrinho de compras
PV-SET 1000 DC
2804445
PHOENIX_CONTACT
1
Kit de dispositivos de proteção contra surtos
Surge protection in IP65 housing for single string photovoltaic systems up to 1000 V DC, connection via SUNCLIX male/female connector.
Home > PHOENIX_CONTACT
Produto novo em sua embalagem original com todas as garantias e certificações de PHOENIX_CONTACT
Obrigado pelo seu interesse nos nossos artigos, esperamos que o prazo indicado seja conveniente para si.
Durante a preparação do pedido pode seleccionar o tipo de envío que melhor se adapte ás suas necessidades: Aéreo Express 24Hrs, Terrestre Standard 48/72Hrs, etc.
| IEC test classification | PV T2 |
| Type | Installation housing |
| Distance between live and grounded parts | 8 mm |
| Number of positions | 2 |
| Surge protection fault message | optical |
| Insulation characteristics | |
| Protection class | II |
| Overvoltage category | III |
| Pollution degree | 2 |
| Nominal current IN | 25 A DC |
| Indicator/remote signaling | |
| Switching function | Changeover contact, 1-pos. |
| Operating voltage | 5 V AC ... 250 V AC |
| 30 V DC | |
| Operating current | 5 mA AC ... 1.5 A |
| 1.5 A DC | |
| PE | |
| Connection method | Screw terminal blocks |
| Screw thread | M5 |
| Tightening torque, min | 4.5 Nm |
| Tightening torque | 4.5 Nm ... 30 lbf-in. (UL) |
| Stripping length | 16 mm |
| Connection method | MC 1,5/3 |
| Screw thread | M2 |
| Tightening torque, min | 0.25 Nm |
| Tightening torque | 2 lbf-in. ... 4 lbf-in. |
| Stripping length | 7 mm |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section, rigid min. | 0.14 mm² |
| Conductor cross section, rigid max. | 1.5 mm² |
| Dimensional drawing | ![]() |
| Width | 125 mm |
| Height | 200 mm |
| Depth | 122 mm |
| Horizontal pitch | 5 Div. |
| Flammability rating according to UL 94 | V2 (Gehäuse / Deckel) |
| V0 (Steckverbinder) | |
| Cover material | Polycarbonate, transparent |
| Housing material | Polycarbonate, glass-fiber-reinforced |
| Connector material | PA |
| Direction of action | (L+)-PE & (L-)-PE & (L+)-(L-) |
| Maximum continuous voltage UC | 1000 V DC |
| Rated load current IL | ≤ 80 A DC |
| Residual current IPE | ≤ 20 µA |
| ≤ 250 µA AC | |
| Standby power consumption PC | ≤ 20 mW |
| Nominal discharge current In(8/20) µs (L+) - (L-) | 15 kA |
| Nominal discharge current In(8/20) µs (L-) - PE | 15 kA |
| Maximum discharge current Imax(8/20) µs (L+) - (L-) | 40 kA |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Voltage protection level Up(L+) - (L-) | ≤ 3.7 kV |
| Voltage protection level Up(L+) - PE | ≤ 3.7 kV |
| Voltage protection level Up(L-) - PE | ≤ 3.7 kV |
| Residual voltage Ures(L+) - (L-) | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Residual voltage Ures(L+) - PE | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Residual voltage Ures(L-) - PE | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Response time tA(L+) - (L-) | ≤ 25 ns |
| Response time tA(L+) - PE | ≤ 25 ns |
| Response time tA(L-) - PE | ≤ 25 ns |
| Max. backup fuse with branch wiring | not required |
| Protective circuit DC voltage side (DC) | |
| Rated surge voltage resistance Uimp | 6 kV |
| Short-circuit current ISCSTC | 25 A DC |
| Open circuit voltage UOCSTC | 830 V DC (Solar generator) |
| Maximum discharge current Imax(8/20) µs (L+) - (L-) | 40 kA |
| Maximum discharge current Imax(8/20) µs (L-) - PE | 40 kA |
| Maximum discharge current Imax(8/20) µs (L+) - PE | 40 kA |
| Response time tA(L+) - (L-) | ≤ 25 ns |
| Response time tA(L+) - PE | ≤ 25 ns |
| Response time tA(L-) - PE | ≤ 25 ns |
| Recommended backup fuse maximum | not required |
| Total discharge current Itotal(8/20) µs | 40 kA |
| Insulation resistance Riso | > 5 GΩ (at 500 V DC) |
| Max. backup fuse with branch wiring | not required |
| Nominal discharge current In(8/20) µs (L+) - (L-) | 15 kA |
| Nominal discharge current In(8/20) µs (L+) - PE | 15 kA |
| Nominal discharge current In(8/20) µs (L-) - PE | 15 kA |
| Rated load current IL | ≤ 80 A DC |
| Residual voltage Ures(L+) - (L-) | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Residual voltage Ures(L+) - PE | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Residual voltage Ures(L-) - PE | ≤ 3.7 kV (at In) |
| ≤ 3.1 kV (at 5 kA) | |
| ≤ 3.5 kV (at 10 kA) | |
| ≤ 4 kV (at 20 kA) | |
| ≤ 4.6 kV (at 30 kA) | |
| ≤ 5 kV (at 40 kA) | |
| Residual current IPE | ≤ 20 µA |
| ≤ 250 µA AC | |
| Voltage protection level Up(L+) - (L-) | ≤ 3.7 kV |
| Voltage protection level Up(L+) - PE | ≤ 3.7 kV |
| Voltage protection level Up(L-) - PE | ≤ 3.7 kV |
| Standby power consumption PC | ≤ 20 mW |
| Ambient conditions | |
| Degree of protection | IP65 |
| IP65 | |
| Impact strength | IK08 |
| Ambient conditions | A, B |
| Ambient temperature (operation) | -30 °C ... 55 °C |
| Air clearances and creepage distances | |
| Standards/regulations | EN 50539-11 |
| Standards/specifications | IEC 61439-2 |
| Note | 2011 |
| Standards/specifications | EN 61439-2 |
| Note | 2011 |
| Standards/specifications | EN 50539-11 |
| Note | Surge protection |
| Mounting type | Surface/Wall mounting |
| Título: | Tamanho: | Tipo: |
|---|---|---|
| PHOENIX CONTACT-2804445-PV-SET 1000 DC | 119 Kbytes |
![]() |
Não há comentários do produto ainda.
| Avaliação: |
|
| Nome: | |
| Email: | |
| Título: | |
| Opinión: | |
| Você recomendaria esse produto para comprar? | |
|
|
|
| Adicionar avaliação | |
Todas as classificações que recebemos a partir dos itens que oferecemos são reais e verificadas. Um pequeno gesto, mas muito valioso. Então, obrigado por esse minuto você gasta em deixar-nos a sua opinião e classificação de produtos, porque nos ajuda a continuar a melhorar e oferecer maior qualidade de serviço.