VAL-MS-T1/T2 175/12.5/1+1-FM
2800674
PHOENIX_CONTACT
1
Universal varistor-based plug-in lightning/surge arrester for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with remote indication contact.
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Height | 99 mm |
---|---|
Width | 35.6 mm |
Depth | 77.5 mm |
Horizontal pitch | 2 Div. |
Degree of protection | IP20 (only when all terminal points are used) |
---|---|
Ambient temperature (operation) | -40 °C ... 80 °C |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 30g |
Vibration (operation) | 7.5g |
IEC power supply system | TT |
---|---|
TN-C | |
TN-S | |
Housing material | PA 6.6 |
PBT | |
Flammability rating according to UL 94 | V-0 |
Color | black |
Standards for cearances and creepage distances | DIN EN 60664-1 |
EN 61643-11 | |
Mounting type | DIN rail: 35 mm |
Type | DIN rail module, two-section, divisible |
Surge protection fault message | Optical, remote indicator contact |
Direction of action | 1L-N & N-PE |
IEC test classification | I / II |
---|---|
T1 / T2 | |
T1 | |
I | |
EN type | T1 / T2 |
T1 | |
Nominal voltage UN | 120 V AC (TN-S) |
Maximum continuous operating voltage UC(L-N) | 175 V AC |
Maximum continuous operating voltage UC(N-PE) | 264 V AC |
UT(TOV-proof) | 208 V AC (5 s / L-N) |
1200 V AC (200 ms / N-PE) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Rated load current IL | 80 A |
Residual current IPE | ≤ 5 µA |
Standby power consumption PC | ≤ 140 mVA |
Max. discharge current Imax(8/20) µs maximum (L-N) | 50 kA |
Max. discharge current Imax(8/20) µs maximum (N-PE) | 50 kA |
Nominal discharge current In(8/20) µs (L-N) | 12.5 kA |
Nominal discharge current In(8/20) µs (N-PE) | 50 kA |
Impulse discharge current (10/350) µs (L-N), charge | 6.25 As |
Impulse discharge current (10/350)˽µs, specific energy | 39 kJ/Ω |
Impulse discharge current (10/350) µs (L-N), peak current value Iimp | 12.5 kA |
Impulse discharge current (10/350) µs (N-PE), charge | 25 As |
Impulse discharge current (10/350) µs (N-PE), specific energy | 625 kJ/Ω |
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp | 50 kA |
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE) | ≤ 1.7 kV |
Voltage protection level Up(L-N) | ≤ 0.8 kV |
Voltage protection level Up(L-PE) | ≤ 2 kV |
Voltage protection level Up(N-PE) | ≤ 1.7 kV |
Residual voltage (L-N) | ≤ 0.65 kV (at 10 kA) |
≤ 0.6 kV (at 5 kA) | |
≤ 0.5 kV (at 3 kA) | |
≤ 0.8 kV | |
Residual voltage (L-PE) | ≤ 1.5 kV (at 10 kA) |
≤ 1.4 kV (at 5 kA) | |
≤ 1.3 kV (at 3 kA) | |
≤ 2 kV | |
Residual voltage (N-PE) | ≤ 0.5 kV (at 10 kA) |
≤ 0.5 kV (at 5 kA) | |
≤ 0.4 kV (at 3 kA) | |
≤ 0.6 kV | |
Response time tA(L-N) | ≤ 25 ns |
Response time (L-PE) | ≤ 100 ns |
Response time tA(N-PE) | ≤ 100 ns |
Max. backup fuse with branch wiring | 160 A AC (gG) |
Max. backup fuse with V-type through wiring | 80 A AC (gG - 16 mm²) |
Short-circuit resistance IPwith max. backup fuse (effective) | 25 kArms |
Short-circuit current rating ISCCR | 25 kA |
Follow current quenching capacity Ifi(N-PE) | 100 A (264 V AC) |
Connection method | Screw connection |
---|---|
Connection type IN | Biconnect screw terminal block |
Connection type OUT | Biconnect screw terminal block |
Connection method | Biconnect terminal block |
Screw thread | M5 |
Tightening torque | 4.5 Nm |
30 lbf-in. (UL) | |
Stripping length | 16 mm |
Conductor cross section flexible min. | 1.5 mm² |
Conductor cross section flexible max. | 25 mm² |
Conductor cross section solid min. | 1.5 mm² |
Conductor cross section solid max. | 35 mm² |
Conductor cross section AWG | 15 ... 2 |
10 ... 2 (UL) |
Connection name | Remote fault indicator contact |
---|---|
Switching function | PDT contact |
Connection method | Screw connection |
Screw thread | M2 |
Tightening torque | 0.25 Nm |
4 lbf-in. | |
Stripping length | 7 mm |
Conductor cross section flexible min. | 0.14 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section solid min. | 0.14 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section AWG | 28 ... 16 |
30 ... 14 (UL) | |
Maximum operating voltage Umax.AC | 250 V AC |
Max. operating current Imax | 1.5 A AC (250 V AC) |
1.5 A DC (30 V DC) |
Standards/regulations | IEC 61643-11 2011 |
---|---|
EN 61643-11 2012 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2800674-VAL-MS-T1/T2 175/12.5/1+1-FM | 135 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.