Technical data

Input data
DC operation
Input voltage48 V DC (UN)
< 60 V DC (Umax)
Input voltage range10 V DC ... 60 V DC
Input voltage range DC10 V DC ... 60 V DC
Voltage type of supply voltageDC
Reverse polarity protection< yes120 V
Nominal input current (IN)2x 20 A
1x 40 A
Maximum current Imax2x 19 A (6 mm² at 40°C)
1x 39 A (6 mm² at 40°C)
2x 16 A (6 mm² at 60°C)
1x 32 A (6 mm² at 60°C)
2x 27 A (10 mm² at 40°C)
1x 54 A (10 mm² at 40°C)
2x 21 A (10 mm² at 60°C)
1x 43 A (10 mm² at 60°C)
2x 30 A (16 mm² at 40 °C)
1x 60 A (16 mm² at 40 °C)
2x 24 A (16 mm² at 60°C)
1x 48 A (16 mm² at 60°C)
Nominal input current (IN)2x 20 A
1x 40 A
Maximum current Imax2x 17 A (6 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 35 A (6 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
2x 14 A (6 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 28 A (6 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
2x 24 A (10 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 49 A (10 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
2x 19 A (10 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 39 A (10 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
2x 27 A (16 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 54 A (16 mm² at 40°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
2x 22 A (16 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
1x 44 A (16 mm² at 60°C for potentially explosive areas: Class I, Div. 2, Groups A, B, C, D; T4)
Transient surge protectionTransil diode
Voltage drop, input/outputapprox. 0.7 V

Output data
Efficiency> 97 %
Nominal output voltage47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V )
Nominal output current (IN)40 A
Power loss nominal load max.28 W
Connection in seriesno

Connection data
Input
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4
Tightening torque, min1.2 Nm
Tightening torque max1.5 Nm
Output
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4
Tightening torque, min1.2 Nm
Tightening torque max1.5 Nm

Electrical properties
Insulation voltage output / PE1 kV
Insulation voltage input / PE1 kV

Product properties
Product typeRedundancy module
Product familyQUINT DIODE
LEDno
Insulation characteristics
Protection classII
Degree of pollution2

Dimensions
Width62 mm
Height84 mm
Depth102 mm
Horizontal pitch3.4 Div.
Installation dimensions
Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm

Mounting
Mounting typeDIN rail mounting
Assembly notealignable: horizontal 20 mm, vertical 50 mm
Mounting positionhorizontal and vertical DIN rail NS 35, EN 60715

Material specifications
Housing materialMetal
Type of housingAIMg (hood), GD-ZnAICu (cooling unit)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C derating,  -25 ... 60°C)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock30g, 18 ms in accordance with IEC 60068-2-27
Vibration (operation)3 Hz ... 15 Hz, amplitude ±2.5 mm; 15 Hz ... 100 Hz, 2.3g according to IEC 60068-2-6
Temp codeT4 (70 °C)

Standards and regulations
Declaration of conformity in acc. with EN 60079-15 II 3 G Ex nA II T4 X
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)

Approvals
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D
Conformity/Approvals
ATEX II 3 G Ex nA II T4

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
Noise emissionEN 55011

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN .pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.