Monitoring relay for temperature monitoring of motor windings (maximum 6 PTC) with error memory, for temperature sensor according to DIN 44081, test function with integrated test/reset button, selectable supply voltage via power module, 2 switched contacts
Monitoring relay for temperature monitoring of the motor winding (maximum 6 PTC) with error memory for temperature sensors in acc. with DIN 44081, test function with integrated test/reset button, supply voltage can be selected via power module, 2 changeover contacts
Relays > Temperature monitoring relay
Industrial Relays
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Utilization restriction | |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Product type | Temperature monitoring relay |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 2 |
| Service life electrical | 2x 105cycles at ohmic load, 1000 VA |
| Rated insulation voltage | 300 V |
| Rated surge voltage | 4 kV |
| Supply | |
| Supply voltage range | 24 V AC ... 230 V AC (see Power modules) |
| 24 V DC (see Power modules) | |
| Nominal power consumption | 2 VA (1.5 W) |
| Input name | Measuring input |
| Maximum input voltage | 7.5 V DC (connection terminal blocks: T1 and T2) |
| Frequency range | 50 Hz ... 60 Hz |
| Maximum temperature coefficient | < 0.1 %/K |
| Response value | ≥ 3.6 kΩ (Relay drops out) |
| Function | Winding temperature monitoring |
| Basic accuracy | ± 10 % (of scale end value) |
| Repeat accuracy | ≤ 2 % |
| Total cold resistance | < 1.5 kΩ |
| Release value | ≤ 1.8 kΩ (Relay picks up) |
| Short-circuit detection | < 20 Ω |
| Voltage influence | ≤ 1 % |
| Recovery time | 500 ms |
| Control | |
| Connection name | Connection of an external reset button (floating controlled N/O contact) |
| Load capacity | Cannot carry load |
| Cable length | max. 10 m |
| Switching | |
| Contact switching type | 2 floating changeover contacts |
| Maximum switching voltage | 250 V AC (in acc. with IEC 60664-1) |
| Interrupting rating (ohmic load) max. | 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing) |
| 1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing) | |
| Output fuse | 5 A (fast-blow) |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Conductor cross section rigid | 0.5 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.25 mm² ... 2.5 mm² |
| Conductor cross section AWG | 20 ... 14 |
| Width | 22.5 mm |
| Height | 90 mm |
| Depth | 113 mm |
| Color | green (RAL 6021) |
| Housing insulation material | Polyamide PA, self-extinguishing |
| Ambient conditions | |
| Degree of protection (Housing) | IP40 (Housing) |
| Degree of protection (Connection terminal blocks) | IP20 (Connection terminal blocks) |
| Ambient temperature (operation) | -25 °C ... 55 °C |
| -25 °C ... 40 °C (corresponds to UL 508) | |
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Permissible humidity (operation) | 15 % ... 85 % |
| CE | |
| Certificate | CE-compliant |
| UL, USA/Canada | |
| Identification | UL/C-UL Listed UL 508 |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Noise immunity | EN 61000-6-2 |
| Noise emission | EN 61000-6-3 |
| Standards/regulations | EN 50178 |
| Mounting type | DIN rail mounting |
| Assembly note | on standard DIN rail NS 35 in accordance with EN 60715 |
| Mounting position | any |
| Feature Name | Feature Value |
|---|---|
| Type of electric connection (EF003961) | Screw connection |
| With detachable clamps (EF003340) | No |
| Error registration possible (EF003423) | No |
| External reset possible (EF003426) | No |
| Number of contacts as normally closed contact (EF008255) | 0 |
| Number of contacts as normally open contact (EF008256) | 0 |
| Number of contacts as change-over contact (EF008257) | 2 |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 90 mm |
| Depth (EF000049) | 113 mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN .pdf | 28 Mbytes |
|
| PHOENIX CONTACT-2866093-EMD-SL-PTC | 128 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.