EV-CC-AC1-M3-CBC-RCM-ETH 1018701 PHOENIX CONTACT AC charging controller View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EV-CC-AC1-M3-CBC-RCM-ETH 1018701 PHOENIX CONTACT AC charging controller

EV-CC-AC1-M3-CBC-RCM-ETH

1018701

PHOENIX_CONTACT

AC charging controller

AC load control system according to IEC 61851-1, Client or Stand-Alone, Modbus-TCP via Ethernet, connection to RFID reader and energy meter via RS-485, DC leakage current monitoring, male connector unlocking in case of power failure

AC charging controller in accordance with IEC 61851-1, client or stand-alone, Modbus/TCP via Ethernet, connection for RFID reader and energy meter via RS-485, DC residual current monitoring, connector release in the event of power failure

More details


Industrial socket/plug applications > Charging controller E-Mobility

E-Mobility

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

Product properties
Product typeAC charging controller
Product familyCHARX control advanced plus
ApplicationAC charging controller for private and commercial applications (EU/CN)
Operating modeStand-Alone
Client
Charging modeMode 3, Case B + C
Data management status
Article revision01
Insulation characteristics
Overvoltage categoryII

System properties
Charging controllers
Number of charging points1

Electrical properties
Type of charging currentAC
Current consumption< 3 W (No-load)
Power consumption< 10 W
Locking release in the event of mains failureIntegrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet
Measuring current transducer
Connection methodConnector
Diameter of measuring coil15 mm
Measuring range: Residual current
Rated frequency fn≤ 2000 Hz
Nominal differential current± 300 mA
Residual current IΔn30 mA (AC)
6 mA (DC)
Rated current In32 A (Three-phase, 4x6 mm²)
48 A (Single-phase)
Tripping time for IΔn< 180 ms
Response time for 2 x IΔn< 70 ms
Tripping time for 5xIΔn< 20 ms
Supply
Supply voltage230 V
Supply voltage range100 V AC ... 240 V AC (nominal voltage range)
Nominal power consumption< 3 W (No-load)
Power consumption< 10 W (maximum)
Frequency range50 Hz ... 60 Hz

Input data
Digital
Number of digital inputs5
Description of the inputDigital input
Nominal current IN≤ 4 mA
Nominal input voltage UN12 V
Input voltage range0 V ... 3 V (Off)
Input voltage range U29 V ... 15 V (On)

Output data
Digital
Output name4 digital outputs
Connection technologyScrew connection
Maximum output voltage30 V
Maximum output current0.2 A (Total current for all outputs; internally supplied)
Maximum output current per channel0.6 A (Per output; externally supplied)
Switching
Output nameRelay output C1.2
Minimum switching capacity4000 VA
Maximum switching voltage250 V AC (External supply)
Max. switching current16 A
Switching
Output nameMotor switching output
Maximum switching voltage12 V (Internal supply)
Max. switching current1 A (maximum)

Connection data
Conductor connection
Connection methodScrew connection
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor connection
Connection methodScrew connection
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1 mm²
Conductor cross section AWG26 ... 16

Interfaces
InterfaceEthernet (1x)
RS-485
InterfaceRS-485 2-wire
Bus systemRS-485
Connection methodScrew connection
Number of interfaces1 (for energy measurement device and RFID reader)
Number of supported devices2
Transmission speed range4.8 kbps ... 115.2 kbps (adjustable)
Protocols supportedModbus/RTU (Master)
Ethernet
InterfaceEthernet
Connection methodRJ45 jack
Number of interfaces1
Serial transmission speed10/100 Mbps
Transmission length100 m
Protocols supportedModbus/TCP

Signaling
Status display5 x LEDs

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude< 2000 m
Permissible humidity (operation)30 % ... 95 % (non-condensing)

Approvals
Conformity/Approvals
ConformanceCE-compliant

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Noise immunityEN 61000-6-2
Immunity to the discharge of static electricityEN 61000-4-2: 8 kV air, 4 kV contact discharge
Immunity to electromagnetic fieldsEN 61 000-4-3, 80---1000 MHz, 10 V/m
Immunity to conducted high frequencyEN 61 000-4-6, 0.15...80 MHz, 10 V
Immunity to fast transients (Burst)EN 61 000-4-4: 2 kV AC mains input, 1 kV data cable
HousingDIN 43880
Noise emissionEN 61000-6-3

Standards and regulations
Standards
Standards/regulationsIEC 61851-1

Mounting
Mounting typeDIN rail mounting
Mounting positionany

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.