Protection set 4-pole with FS, 255V,
PS4-B+C TNS+FS protection set, 4 poles, with FS 255V,
Protection set MCD + V20 3-pole + NPE with remote signalling. Protection set, lightning and surge arrester type 1+2 • Arresting capacity 100 kA 10/350 µs, BET-tested • Pre-mounted and ready for connection, incl. connecting bridges, labelled connection terminals• With remote signalling and potential-free NO contact for function monitoring• For use in TN-S and TT network systemNote: Max. backup fuse (required only if not already fitted in network) 125 A gL/gG.
Earthing, lightning and surge protection > Combined arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 1+2 (office and housing) - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrester surge current (8/20 µs) [total] | 100 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 11,0412 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 50 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 10 mm² |
| Dimension | 255V |
| Follow current quenching capacity (eff) [N-PE] | 25 kA |
| Installation type | DIN rail 35 mm |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 50 kA |
| Lightning surge current (10/350) | 100 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage (L-N) | 255 V |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 100 kA |
| Network form | Other |
|---|---|
| Nominal discharge current (8/20 µs) | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 85 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 85 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3+N/PE |
| Protection rating | IP20 |
| Remote signalling | yes |
| Response time | <25 ns |
| Short-circuit resistance | 25 kA |
| Short-circuit resistance for max. mains-side overcurrent protection | 25 kA |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 3+1-pole with FS; 255 V |
| Feature Name | Feature Value |
|---|---|
| Lightning impulse current (10/350 µs) (EF000421) | 50 kA |
| Max. continuous voltage AC (EF004198) | 255 V |
| Nominal voltage AC (EF004220) | 230 V |
| Voltage protection level (EF003525) | 1.7 kV |
| Follow current extinguishing capability (EF004193) | 25 kA |
| Mounting method (EF000003) | DIN rail (top hat rail) 35 mm |
| Construction size (EF002566) | Other |
| Max. conductor cross section solid (solid, stranded) (EF008827) | 50 mm² |
| Signalling at the device (EF004241) | Optic |
| Degree of protection (IP) (EF005474) | IP20 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| PS4-B+C TNS+FS 5089763 OBO BETTERMANN Protection set 4-pole with FS, 255V, | 66 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.