Viewed products

Surge protection, arrestor, type 1+2 (office and housing) - OBO BETTERMANN

Surge protection devices (SPDs), also known as surge arrestors or transient voltage surge suppressors (TVSS), are critical components for safeguarding electrical installations against overvoltages caused by lightning strikes or switching operations. Type 1+2 arrestors combine the high-energy discharge capability of Type 1 (10/350 µs waveform) wi...

Surge protection devices (SPDs), also known as surge arrestors or transient voltage surge suppressors (TVSS), are critical components for safeguarding electrical installations against overvoltages caused by lightning strikes or switching operations. Type 1+2 arrestors combine the high-energy discharge capability of Type 1 (10/350 µs waveform) with the overvoltage limitation of Type 2 (8/20 µs waveform), making them ideal for main distribution boards in office and housing applications. These devices typically feature a rated voltage of 230/400 V AC, a nominal discharge current (In) of 20 kA per pole, and a maximum discharge current (Imax) of up to 50 kA. They are available in configurations such as 1P, 1P+N, 3P, 3P+N, and 4P, with pluggable modules for easy replacement. Key parameters include the voltage protection level (Up), which should be below 1.5 kV for sensitive equipment, and the short-circuit withstand capacity (Isc) up to 25 kA. Common standards include IEC 61643-11 and EN 61643-11, ensuring compliance with international safety regulations.

These surge arrestors are primarily installed in main low-voltage switchboards, sub-distribution boards, and building entrance panels. They protect sensitive electronic equipment such as computers, servers, HVAC controls, lighting systems, and security devices in residential and commercial buildings. In office environments, they safeguard critical infrastructure like network switches, UPS systems, and telecommunication equipment. For housing applications, they protect household appliances, smart home systems, and entertainment electronics. Type 1+2 devices are also used in industrial control panels, photovoltaic systems, and EV charging stations where combined lightning and surge protection is required. Their compact design allows for easy integration into existing electrical enclosures with DIN rail mounting.

The main subcategories include pluggable surge arrestors (e.g., OBO BETTERMANN V20-C/3-PH, V25-B+C/3-PH, and MC50-B/3-PH), which feature a modular design with thermal disconnection and visual status indication. The article codes typically follow a pattern like "V20-C/3-PH" where "V20" indicates the series, "C" the protection class, "3" the number of poles, and "PH" the phase configuration. Other relevant articles include the OBO BETTERMANN TNC-25/3-PH for TN-C systems and the V50-B+C/3-PH for higher discharge capacities. These devices often come with optional remote signaling contacts (e.g., V20-C/3-PH-FS) for integration into building management systems.

Partnering with Electric Automation Network ensures access to genuine OBO BETTERMANN surge protection devices with real-time pricing and up to 65% discount compared to market rates. Our engineering team provides personalized technical support for selecting the correct SPD type based on your system's lightning protection level (LPL), risk assessment, and equipment sensitivity. We offer express worldwide shipping with tracking, ensuring your critical components arrive within 3-5 business days. Each product includes detailed technical documentation, wiring diagrams, and installation guidelines. Our multilingual portal allows you to compare specifications, check stock availability, and place orders 24/7.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

5089748

PS 2-B+C/TT+TNS

-

Protection set two-pole design,

3 View Availability View Price

5089761

PS4-B+C TT+TNS

-

Protection set 4-pole design, 255V,

PS4-B+C TT+TNS protection set, Tetrapolar type 255V,

Protection set MCD + V20 3-pole + NPE. Protection set, lightning and surge arrester combination, type 1+2• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity to 50 kA (10/350) per pole and up to 125 kA (10/350) N-PE• Arrester, connectable, including connecting bridges, labelled connection terminals• Encapsulated, non-extinguishing arrester for use in distributor housings Application: Mobile telecommunications systems and industrial systems with special requirements.

2 View Availability View Price

5089763

PS4-B+C TNS+FS

-

Protection set 4-pole with FS, 255V,

PS4-B+C TNS+FS protection set, 4 poles, with FS 255V,

Protection set MCD + V20 3-pole + NPE with remote signalling. Protection set, lightning and surge arrester type 1+2 • Arresting capacity 100 kA 10/350 µs, BET-tested • Pre-mounted and ready for connection, incl. connecting bridges, labelled connection terminals• With remote signalling and potential-free NO contact for function monitoring• For use in TN-S and TT network systemNote: Max. backup fuse (required only if not already fitted in network) 125 A gL/gG.

2 View Availability View Price

5089770

PS4-VA TT+TNS

-

Protection set 4-pole + leakage current-free, 255V,

3 View Availability View Price

5089777

PS4-VA TT+FS

-

Protection set 4-pole w.FS, leak.current-free, 255V,

3 View Availability View Price

5093627

V50-B+C 3-280

-

CombiController V50 3-pole version, 280V,

V50 V50-B+C 3-280 combined discharger, 3 pole version 280V,

3 View Availability View Price

5093643

V50-B+C 3+FS280

-

CombiController V50 3-pole with remote signalling, 280V,

3 View Availability View Price

5093653

V50-B+C 1+NPE

-

CombiController V50 1-pole + NPE, 280V,

Lightning current and surge arrester, 1-pole + NPE. Combination arrester, lightning and surge arrester type 1+2 to DIN EN 61643-11.• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity 12.5 kA (10/350) per pole and 50 kA (10/350) in total• Universally suitable for TN and TT systems• With new Multibase base with multi-connection terminals• Complete unit, consisting of upper part and base, pre-mounted and ready for connection• Arrester, connectable with dynamic cut-off unit• With visual function display• Protection level < 1.3 kV• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• Labelled connections Application: Equipotential bonding in buildings, even those with external lightning pro

3 View Availability View Price

5093654

V50-B+C 3+NPE

-

CombiController V50 3-pole + NPE, 280V,

Combined discharger V50 V50-B+C 3+NPE, version 3+1 280V,

3 View Availability View Price

5093661

V50-B+C 1+NPE+FS

-

CombiController V50 1-pole + NPE w. remote signal, 280V,

Lightning current and surge arrester, 1-pole + NPE with remote signalling. Combination arrester, lightning and surge arrester type 1+2 to DIN EN 61643-11.• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity 12.5 kA (10/350) per pole • Universally suitable for TN and TT systems• With Multibase base with multi-connection terminals• Complete unit, consisting of upper part and base, pre-mounted and ready for connection• Arrester, connectable with dynamic cut-off unit• With visual function display• Protection level < 1.3• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• Labelled connections• FS variant with remote signalling contact (potential-free NO contact) Application: Equipotential

3 View Availability View Price

5093662

V50-B+C 3+NPE+FS

-

CombiController V50 3-pole + NPE w. remote signal, 280V,

Lightning current and surge arrester, 3-pole + NPE with remote signalling. Combination arrester, lightning and surge arrester type 1+2 to DIN EN 61643-11.• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity 12.5 kA (10/350) per pole • Universally suitable for TN and TT systems• With Multibase base with multi-connection terminals• Complete unit, consisting of upper part and base, pre-mounted and ready for connection• Arrester, connectable with dynamic cut-off unit• With visual function display• Protection level < 1.3• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in distributor housings• Labelled connections• FS variant with remote signalling contact (potential-free NO contact) Application: Equipotential

3 View Availability View Price

5093724

V50-B+C 0-280

-

CombiController V50 plug-in arrester, 280V,

CombiController V50, plug-in arrester 280 V. CombiController upper part– type 1+2 combination arrester • Plug-in upper part can be fitted into the base without tools or current interruption• Incl. thermal and dynamic cut-off unit and visual display of defects• High current conductivity and long service lifePlug-in arrester

3 View Availability View Price

5094418

V25-B+C 1-280

-

CombiController V25 single pole version, 280V,

Combination arrester V25, 1-pole 280 V. Combination arrester, lightning and surge arrester type 1+2• Complete unit consisting of upper part and base, pre-mounted and ready for connection• For TN systems• Plug-in arrester with dynamic cut-off unit• With visual function display• Protection level decoded:705:Value:RAM1; kV • Encapsulated, non-extinguishing zinc oxide varistor arrester for use in standard distributor housings• Labelled connections Application example: Buildings with open-wire power supply or for setting up lightning protection equipotential bonding in residential buildings.* Complete = cover and base

3 View Availability View Price

5094421

V25-B+C 2-280

-

CombiController V25 two-pole design, 280V,

3 View Availability View Price

5094444

V25-B+C 1+NPE+FS

-

CombiController V25 1+1 version with FS, 280V,

Combination arrester V25, 1-pole + NPE 280 V with remote signalling. Combination arrester, lightning and surge arrester type 1+2• Complete unit consisting of upper part and base, pre-mounted and ready for connection• Universally suitable for TN and TT systems• With remote signalling and potential-free NO contact for function monitoring• Plug-in arrester with dynamic cut-off unit• Visual function display• Voltage protection level < 0.9 kV• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in standard distributor housings• Labelled connections• FS variant with remote signalling contact (potential-free NO contact)Application example: Buildings with open-wire power supply or for setting up lightning protection equipotential bonding in residential buildings.* Complete = Plu

3 View Availability View Price

5094457

V25-B+C 1+NPE

-

CombiController V25 1+1 version, 280V,

Combination arrester V25, 1-pole + NPE 280 V. Combination arrester, lightning and surge arrester type 1+2• Complete unit consisting of upper part and base, pre-mounted and ready for connection• Universally suitable for TN-S and TT systems• Plug-in arrester with dynamic cut-off unit• Visual function display• Voltage protection level < 0.9 kV• Encapsulated, non-extinguishing zinc oxide varistor arrester for use in standard distributor housings• Labelled connectionsApplication example: Buildings with open-wire power supply or for setting up lightning protection equipotential bonding in residential buildings.* Complete = Plug-in arrester and base

2 View Availability View Price

5094463

V25-B+C 3+NPE

-

CombiController V25 3+1 version, 280V,

Combined discharger V25 V25-B+C 3+NPE, Type 3+1 280V,

2 View Availability View Price

5094510

V25-B+C 3+NPE-FS

-

CombiController V25 3+1 with remote signalling, 280V,

Combined discharger V25 V25-B+C 3+NPE-FS,3+1 with remote signaling 280V,

3 View Availability View Price

5095603

C 25-B+C 0

-

Lightning current conductor choose N against PE,

Plug-in arrester, total spark gap between N and PE 255 V. Plug-in total discharge gap for use between neutral lines (N) and protector (PE) Suitable for use in combination with: • CombiController, type V 25-B+C• SurgeController, type V 20-C• SurgeController, type V 10-C* Complete = Plug-in arrester and base

2 View Availability View Price

5095606

C 25-B+C 1

-

NPE discharge gap including bottom part,

Spark path NPE C 25-B+C 1, includes 255V socket,

3 View Availability View Price

5096675

MB 50-3+NPE

-

Multibase MB50 3-pole + NPE,

CombiController V50 base. Base for V 50-B+C, combination arrester, lightning and surge arrester, type 1+2 • Suitable for V25-B+C, V20-C and V10-C• Pre-mounted and ready for connection• Multifunction terminals for easy connection with series-mounted devices• Upper parts can be rotated through 180 degrees• 3+1 protection circuit for TN-S and TT network systems Application: Lightning protection equipotential bonding in buildings, even those with external lightning protection of class III and IV, and in standard distributor housings.Base

3 View Availability View Price

5096677

MB 50-3+NPE+FS

-

Multibase MB50 3-pole + NPE w. signal contact,

3 View Availability View Price

5097053

V25-B+C 0-280

-

CombiController V25 plug-in arrester, 280V,

CombiController V25, upper part 280 V. Combination arrester – type 1+2 • Plug-in arrester can be separated from base without tools and current cut-off in base• Including thermal and dynamic cut-off unit and visual fault display • High current conductivity and long service life

2 View Availability View Price

5097055

V25B 0 SO-280

-

3 View Availability View Price

5097061

V25-B+C 0-385

-

CombiController V25 plug-in arrester, 385V,

Combined discharger V25 V25-B+C 0-385, active part 385V,

3 View Availability View Price

5097088

V25-B+C 0-150

-

CombiController V25 plug-in arrester, 150V,

Combined discharger V25 V25-B+C 0-150, active part 150V,

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.