Protection set 4-pole design, 255V,
PS4-B+C TT+TNS protection set, Tetrapolar type 255V,
Protection set MCD + V20 3-pole + NPE. Protection set, lightning and surge arrester combination, type 1+2• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)• Lightning current arresting capacity to 50 kA (10/350) per pole and up to 125 kA (10/350) N-PE• Arrester, connectable, including connecting bridges, labelled connection terminals• Encapsulated, non-extinguishing arrester for use in distributor housings Application: Mobile telecommunications systems and industrial systems with special requirements.
Earthing, lightning and surge protection > Combined arrester for power supply systems
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 1+2 (office and housing) - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrester surge current (8/20 µs) [total] | 100 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 10,8946 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 50 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 10 mm² |
| Dimension | 255V |
| Follow current quenching capacity (eff) [N-PE] | 25 kA |
| Installation type | DIN rail 35 mm |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350 μs) | 50 kA |
| Lightning surge current (10/350) | 100 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage (L-N) | 255 V |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 255 V |
| Maximum discharge current (8/20 μs) | 100 kA |
| Network form | Other |
|---|---|
| Nominal discharge current (8/20 µs) | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 85 °C |
| Operating temperature, min. | -40 °C |
| Permitted temperature range, max. | 85 °C |
| Permitted temperature range, min. | -40 °C |
| Pole version | 3+N/PE |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Short-circuit resistance | 25 kA |
| Short-circuit resistance for max. mains-side overcurrent protection | 25 kA |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| Version for | 3-pole with NPE; 255 V |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| PS4-B+C TT+TNS 5089761 OBO BETTERMANN Protection set 4-pole design, 255V, | 62 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.