SWIRE-DIL 107028 EATON ELECTRIC Coupling module, SmartWire-DT, for contactors, DILM View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SWIRE-DIL 107028 EATON ELECTRIC Coupling module, SmartWire-DT, for contactors, DILM

SWIRE-DIL

107028

EATON-MOELLER

5

Coupling module, SmartWire-DT, for contactors, DILM

More details


PLC's > Fieldbus, decentr. periphery - digital I/O module

Home > EATON - MOELLER

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Coupling module, SmartWire-DT, for contactors, DILM
Eaton Catalog No.
SWIRE-DIL
EL-Nummer (Norway)
0004131950
SWIRE module (slave) for decentral actuation of contactors DIL / motor-starter combination with 24VDC coil voltage. Functions: control section contactor, feedback signal contactor status, feedback signal of the integrated digital input
[

Delivery program

Subrange
Module
Basic function
Connection system SmartWire
Description
SmartWire module to assemble on the contactors DILM(C)7…DILM(C)38, DILA…, DIMP20
- One module is necessary per contactor.
- Connection to SmartWire- Gateway as module.
- Max. 16 SmartWire modules per rung.
- 1 digital input for potential-free contact.
- Signalling contactor switch position.
Notes
  • Take account of the max. current consumption of the contactor coils per SmartWire chain.
  • Length of connection cable at the input and the electrical interlock < 2.8 m.
  • The A2 connection of the contactors must not be bridged.
  • Electrical interlocking only possible via the terminals on the module for DILM.
  • Wiring kits DILM 12-XRL and PKZM0-XRM12 cannot be used.
  • Connection terminals for electrical interlocking are not suitable for safety technology.
,

Technical data

General
StandardsGeneral
IEC/EN 60947
EN 55011
EN 55022
IEC/EN 61000-4
IEC/EN 60068-2-27
Mounting
on DILM7…DILM38
Dimensions (W x H x D)
45 x 44 x 81 mm
Weight
0.036 kg
Terminal capacities
Solid
0.34…1.5 mm2
Flexible with ferrule
0.34…1.5 mm2
Solid or stranded
22…16 AWG
Standard screwdriver
3.5 x 0.8 mm
Max. tightening torque
0.5 Nm
Climatic environmental conditions
Ambient temperatureOperation
-25 - +60 °C
Ambient temperatureStorage
- 25 - + 70 °C
Condensation
Take appropriate measures to prevent condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Air pressure (operation)
795 - 1080 hPa
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Overvoltage category/pollution degree
2
Mounting position
as DILM7 to DILM38
Electromagnetic compatibility (EMC)
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)Air discharge
8 kV
Electromagnetic fields (IEC/EN 61000-4-3, RFI) [V/m]
10
Radio interference suppression EN 55011, EN 55022
Class A
Burst Impulse (IEC/EN 61000-4-4, Level 3)Supply cable
2 kV
Burst Impulse (IEC/EN 61000-4-4, Level 3)Signal lines
2 kV
power pulses (surge) (IEC/EN 61000-4-5, level 2)
0.5 (supply cables, symmetrical) kV
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
10 V
Insulation resistance
Clearance in air and creepage distances
EN 50178, EN 60947-1, UL 508, CSA C22.2 No 142
Insulation resistance
EN 50178, EN 60947-1
Voltage supply, Gateway electronic and SmartWire station electronics UGateway
Admissible range
Supply from Gateway or Power module
Heat dissipation at 24 V DC
typically 0.6 W
Power supply UAUX (power supply for switching SmartWire elements e.g. contactor coils)
Rated operational voltage UAux
Supply from Gateway or Power module V DC
Admissible range
Supply from Gateway or Power module V DC
LEDs
Ready for operation
Ready: green
Status SmartWire
over Ready
Connection potential-free contacts
Number
1
Rated voltage (own supply) [Ue]
17 V DC
Input current at “1” signal, typically
5 mA
max. conductor length
< 2.8 m
MODBUS
Potential isolationfor supply voltage UGateway
No
Potential isolationTo SmartWire
to supply voltage UAUX: no
to supply voltage UGateway: no
SmartWire
Connection types
Plug, 6-pole
Data/power cable
6 core flat-band cable
maximum cable length System SmartWire
4 m
Bus termination
Connector plug
Station address
1…16
Station
max. 16 per SmartWire chain
Address allocation
Automatic via SmartWire
Function
SmartWire-Slave
Data transfer time System SmartWireWrite switch
typically 20 ms for all stations
Data transfer time System SmartWireRead status information
typically 10 ms per station
Relay outputs
Overvoltage category/pollution degree
III/3
Conventional thermal current [Ith]
4 A
,

Design verification as per IEC/EN 61439

Technical data for design verification
Rated operational current for specified heat dissipation [In]
0 A
Heat dissipation per pole, current-dependent [Pvid]
0 W
Equipment heat dissipation, current-dependent [Pvid]
0 W
Static heat dissipation, non-current-dependent [Pvs]
0.6 W
Heat dissipation capacity [Pdiss]
0 W
Operating ambient temperature min.
-25 °C
Operating ambient temperature max.
+60 °C
IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
,

Technical data ETIM 7.0

PLC's (EG000024) / Fieldbus, decentr. periphery - digital I/O module (EC001599)
Electric engineering, automation, process control engineering / Control / Field bus, decentralized peripheral / Field bus, decentralized peripheral - digital I/O module ([email protected] [BAA055014])
Supply voltage AC 50 Hz
0 - 0 V
Supply voltage AC 60 Hz
0 - 0 V
Supply voltage DC
17 - 17 V
Voltage type of supply voltage
DC
Voltage type of supply voltage
DC
Number of digital inputs
2
Number of digital outputs
1
Digital inputs configurable
No
Digital outputs configurable
No
Input current at signal 1
5 mA
Permitted voltage at input
17 - 17 V
Type of voltage (input voltage)
DC
Type of voltage (input voltage)
DC
Type of digital output
Other
Output current
0.5 A
Permitted voltage at output
20.4 - 28.8 V
Type of output voltage
DC
Type of output voltage
DC
Short-circuit protection, outputs available
No
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
2
With optical interface
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for MODBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Bluetooth
No
Radio standard WLAN 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
System accessory
Yes
Degree of protection (IP)
IP20
Type of electric connection
Screw connection
Time delay at signal exchange
0 - 0 ms
Fieldbus connection over separate bus coupler possible
Yes
Rail mounting possible
No
Wall mounting/direct mounting
No
Front build in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
Category according to EN 954-1
1
SIL according to IEC 61508
None
Performance level acc. EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
45 mm
Height
38 mm
Depth
70 mm
,

Approvals

Product Standards
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
UL File No.
E29184
UL Category Control No.
NKCR
CSA File No.
012528
CSA Class No.
2252-01
North America Certification
UL listed, CSA certified
Specially designed for North America
No
,

Dimensions

SWIRE-DIL
]

Datasheet - PDF

Title: Size: Type:
PDF CATALOGUE EATON EN.pdf 51 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.