Product successfully added to your shopping cart
GSTA2
021996
EATON-MOELLER
1
NH fuse switch-disconnector, 400A, 500V/400A, 690V/315A, size 2
Home > EATON - MOELLER
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
For fitting on mounting plate | |||
Number of poles | 3 pole | ||
Rated operational current | Ie | A | 400 |
Max. fuse | |||
500 V | A | 400 | |
690 V | A | 315 | |
Frame size | NH2 | ||
For use with | In conjunction with adapter plates: A-GSTA... |
General | |||
Standards | IEC/EN 61131-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | °C | -20 - +55 | |
Altitude | m | Max. 2000 | |
Mounting position | Vertical or horizontal | ||
Overvoltage category/pollution degree | III/3 | ||
Degree of protection, from the front | |||
Operational state | IP20 | ||
Front cover open | IP10 | ||
Direction of incoming supply | as required | ||
Lifespan, mechanical | Operations | 800 | |
Weight | kg | 3.3 | |
Contacts | |||
Rated operational voltage | Ue | V AC | 500 |
Rated operational voltage | Ue | V DC | 220 |
Rated operational current | Ie | A | 400 |
Rated frequency | f | Hz | 40 - 60 |
Rated conditional short-circuit current AC | Iq | kAeff | 50 |
Rated conditional short-circuit current, DC | Iq | kArms | 25 |
Utilization category AC22B | |||
Rated making capacity | A | 1200 | |
Rated breaking capacity | A | 1200 | |
Utilization category DC21B | |||
Rated making capacity | A | 475 | |
Rated breaking capacity | A | 475 | |
Lifespan, electrical | Operations | 200 | |
Lifespan, mechanical | Operations | 800 | |
Heat dissipation at IthAC, without NH-SE | W | 27 | |
Heat dissipation at IthDC, without NH-SE | W | 18 | |
Rated insulation voltage | Ui | V AC | 750 |
Rated impulse withstand voltage | Uimp | kV | 8 |
Rated insulation voltage | Ui | V | 750 |
Max. fuse | |||
Frame size | NH2 | ||
Max. rated current, gL/gG | A | 400 | |
Max. admissible heat dissipation NH-SE | Pv | W | 34 |
Terminal capacity | |||
Flange connection | |||
Main cable | d | mm | M10 |
Cable lug | mm2 | 1 x 25 - 240 | |
Flat busbar | max. | mm | 30 x 10 |
Tightening torque | Nm | 30 - 35 | |
Box terminal | |||
Stranded copper | mm2 | 25 … 240 | |
Copper braid | Lamellenzahl x Breite x Dicke | mm | 10 x 16 x 0.8 |
Tightening torque | Nm | 23 | |
Clamp-type terminal | |||
Stranded aluminium/copper | mm2 | 120 … 240 | |
Tightening torque | Nm | 11 | |
Double clamp-type terminal | |||
Stranded aluminium/copper | mm2 | 2 x (120 - 150) | |
Tightening torque | Nm | 11 | |
Notes | |||
Fuse-link |
Low-voltage industrial components (EG000017) / Fuse switch disconnector (EC001040) | |||
Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Fuse switch disconnector ([email protected] [AKF058013]) | |||
Version as main switch | No | ||
Version as safety switch | No | ||
Max. rated operation voltage Ue AC | V | 690 | |
Rated permanent current Iu | A | 400 | |
Rated operation power at AC-23, 400 V | kW | 0 | |
Conditioned rated short-circuit current Iq | kA | 80 | |
Rated short-time withstand current lcw | kA | 0 | |
Suitable for fuses | NH2 | ||
Number of poles | 3 | ||
With error protection | No | ||
Type of electrical connection of main circuit | Cable clamp | ||
Cable entry | |||
Equipped with connectors | |||
Suitable for ground mounting | Yes | ||
Suitable for front mounting 4-hole | No | ||
Suitable for busbar mounting | No | ||
Type of control element | Cover grip | ||
Position control element | Front side | ||
Motor drive optional | No | ||
Motor drive integrated | No | ||
Version as emergency stop installation | No | ||
Degree of protection (IP), front side | IP20 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOGUE EATON EN.pdf | 51 Mbytes | |
NH fuse switch-disconnector, 400A, 500V/400A, 690V/315A, size 2 - EATON - GSTA2 - 21996 | 212 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.