EASY223-SWIRE 106950 EATON ELECTRIC Gateway CANopen-easyNet/SmartWire View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EASY223-SWIRE 106950 EATON ELECTRIC Gateway CANopen-easyNet/SmartWire

EASY223-SWIRE

106950

EATON-MOELLER

Gateway CANopen-easyNet/SmartWire

More details


EASY programmable relays and MFD displays

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Delivery programme
Description
Gateway for connecting up to 16 SmartWire modules to easyNet or CANopen®
Notes

easy‐NET operating mode

CANopen® operating mode

In easy-NET mode the gateway acts as a station on easy-NET and the SmartWire master at the same time. Up to 8 stations on the easy‐NET can be intelligently connected with each other.

CANopen® mode allows communication between SmartWire modules and controllers with CANopen® interface such as EC4‐200 or XC100/200. In addition to standard fieldbus modules such as remote I/O systems or visualisation devices, this allows a number of switchgear devices can be networked directly with the PLC. Up to 126 stations can be connected to a CANopen® network, depending on the performance level of the CANopen® fieldbus master.

General
Standards
EN 55011, EN 55022, IEC/EN 61000-4, IEC/EN 60068-2-27, EN 50325
Dimensions (W x H x D)
mm 35.5 x 90 x 58 (2 PE)
Weight
kg 0.15
Mounting
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Terminal capacities
Solid
mm2 0.34 - 1.5 (AWG 22 - 16)
Flexible with ferrule
mm2 0.34 - 1.5 (AWG 22 - 16)
Standard screwdriver
mm 3.5 x 0.8
Max. tightening torque
Nm 0.6
Climatic environmental conditions
Operating ambient temperature
°C -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2
Condensation
Take appropriate measures to prevent condensation
Storage
°C - 25 - 70
Relative humidity, non-condensing (IEC/EN 60068-2-30)
% 5 - 95
Air pressure (operation)
hPa 795 - 1080
Corrosion resistance
cm³/m³
IEC/EN 60068-2-42
4 days SO2 cm3/m3 10
IEC/EN 60068-2-43
4 days H2S cm3/m3 1
Ambient conditions, mechanical
Protection type (IEC/EN 60529, EN50178, VBG 4)
IP20
Vibrations (IEC/EN 60068-2-6)
Hz
Constant amplitude 0.15 mm
Hz 10 - 57
Constant acceleration 2 g
Hz 57 - 150
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms
Impacts 18
Drop to IEC/EN 60068-2-31
Drop height mm 50
Free fall, packaged (IEC/EN 60068-2-32)
m 1
Mounting position
Vertical (on horizontal top-hat rail)
Electromagnetic compatibility (EMC)
Overvoltage category/pollution degree
II/2
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD)
kV
Air discharge
kV 8
Contact discharge
kV 4
Electromagnetic fields (RFI) to IEC EN 61000-4-3
V/m 10
Radio interference suppression
EN 55011 Class B, EN 55022 Class B
Burst Impulse (IEC/EN 61000-4-4, Level 3)
Supply cable
kV 2
Signal lines
kV 2
power pulses (surge) (IEC/EN 61000-4-5, level 2)
kV 0.5 (supply cables, symmetrical)
Immunity to line-conducted interference to (IEC/EN 61000-4-6)
V 10
Insulation resistance
Clearance in air and creepage distances
EN 50178, UL 508, CSA C22.2, No. 142
Insulation resistance
EN 50178
Power supply
Rated operational voltage
Ue V 24 (-15/+20 %)
Admissible range
V DC 20.4 - 28.8
Residual ripple
% < 5
at 24 V DC
mA Normally 200
Voltage dips
ms ≤ 10
Heat dissipation at 24 V DC
W 2
Protection against polarity reversal
AS-I power supply
Yes
PROFIBUS DP
Potential isolation
Yes, for UAUX, UGATEWAY, SmartWire
Baud rates
1000 (6 m) … 10 kBit/s (1000 m) easyNet: adjustable via easyNet configuration (station 1) or terminal mode with CANopen®: automatic
Bus terminating resistors
External, first and last station
Bus addresses
easyNet: 2 … 8, adjustable via easyNet configutarion (station 1) or terminal mode CANopen®: 1 … 126, adjustable via DIP switches
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
Rated operational current for specified heat dissipation
In A 0
Heat dissipation per pole, current-dependent
Pvid W 0
Equipment heat dissipation, current-dependent
Pvid W 0
Static heat dissipation, non-current-dependent
Pvs W 2
Heat dissipation capacity
Pdiss W 0
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Dimensions
IL05013003Z (AWA2528+1251-2355) Connection system SmartWire: Gateway easyNet/CANopen
>
>
>
>
>
>>

Datasheet - PDF

Title: Size: Type:
PDF EATON SAFETY LOGIC EN.pdf 2 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.