EMS-DO-T-2,4-24VDC 170099 EMS-DO-T-2P4-24VDC EATON ELECTRIC 170099 EMS-DO-T-2,4-24VDC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EMS-DO-T-2,4-24VDC 170099 EMS-DO-T-2P4-24VDC EATON ELECTRIC 170099 EMS-DO-T-2,4-24VDC

EMS-DO-T-2,4-24VDC

170099

EMS-DO-T-2P4-24VDC

EATON-MOELLER

170099 EMS-DO-T-2,4-24VDC

Electronic starter; Direct start; 2.4 A

DOL starter, 24 V DC, 0,18 - 2,4 A, Push in terminals, PTB 13 ATEX 3003

DOL starter, Actuating voltage: 24 V DC, Standards: IEC/EN 60947-4-2, UL508

More details


Low-voltage industrial components > Motor starter/Motor starter combination

Standard Soft Starters

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series EMS DOL starter
Catalog Number
170099
Model Code
EMS-DO-T-2,4-24VDC
EAN
4015081665969
Product Length/Depth
160 mm
Product Height
60 mm
Product Width
155 mm
Product Weight
0.3 kg
Certifications
IEC/EN 61000-4-3
Certified by UL for use in Canada
UL File No.: E29096
PTB 13 ATEX 3003
IEC/EN 60947-4-2
IEC/EN 60947-5
UL Category Control No.: NLDX, NLDX7
UL 508
CSA-C22.2 No. 14
CE
UL508
UL report applies to both US and Canada
IEC/EN 61000-4-2, Level 3
UL

Features & Functions

Functions
External reset possible
DOL starting
Motor protection
Temperature compensated overload protection

General

Balance monitoring
If ≥ 33 %, pick-up time of 120 s, Magnitude Imax > Irated ((Imax - Imin)/Imax)
If ≥ 33 %, pick-up time of 120 s, Magnitude Imax < Irated ((Imax - Imin)/Imax)
If ≥ 67 %, pick-up time of 1.8 s, Magnitude Imax < Irated ((Imax - Imin)/Imax)
If ≥ 67 %, pick-up time of 1.8 s, Magnitude Imax > Irated ((Imax - Imin)/Imax)
Class
CLASS 10
Connection to SmartWire-DT
No
Degree of protection
IP20
IP20 (according to IEC/EN 60529, EN 50178, VBG 4)
Lifespan, electrical
30,000,000 Operations
Model
Direct starter
Mounting method
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible
Mounting position
Vertical
Motor feeder at bottom
Operating frequency
7200 Operations/h (pulse pause time 50:50)
Overload release current setting - min
0.18 A
Overload release current setting - max
2.4 A
Overvoltage category
III
Pollution degree
2
Product category
Electronic motor starter
Rated impulse withstand voltage (Uimp)
6000 V AC
Recovery time
20 min (automatic restart)
2 min (manual startup)
Residual ripple
≤ 5 % (input voltage)
Terminal capacity
2 x (0.75 - 2.5) mm², flexible with ferrule
1 x (0.75 - 2.5) mm², solid
2 x (0.75 - 1.5) mm², flexible, with twin ferrule
Minimum length 10 mm.
Terminal capacity (AWG)
1 x (20 - 14), flexible with ferrule
2 x (20 - 16), flexible with twin ferrule
1 x (20 - 14), solid
Type
DOL starter (complete device)
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C
Ambient storage temperature - min
-40 °C
Ambient storage temperature - max
80 °C
Environmental conditions
Condensation: prevent with appropriate measures
Designed for operation in industrial environments. The use in residential environments could cause electrical interference so that addition suppression must be planned.

Electro magnetic compatibility

Air discharge
8 kV
Burst impulse
2 kV
According to IEC/EN 61000-4-4, level 3
Contact discharge
6 kV
Electromagnetic fields
3 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
10 V/m at 800 - 1000 MHz (according to IEC EN 61000-4-3)
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Radio interference class
Class A (EN 55011, emitted interference, line-conducted)
Class A (EN 61000-6-3, emitted interference, radiated)
Surge rating
1 kV, symmetrical, power pulses (Surge), EMC
2 kV, asymmetrical, power pulses (Surge), EMC
According to IEC/EN 61000-4-5, power pulses (Surge), EMC

Electrical rating

Basic insulation
500 V AC, between supply voltage, control voltage and switch voltage according to IEC/EN60947-1
500 V AC, between feedback signal output and switch voltage according to IEC/EN60947-1
Input current
40 mA (without feedback signal)
5 mA (Actuating circuit - ON, L, R)
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V
0 A
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
24 V
Rated control supply voltage (Us) at DC - max
24 V
Rated operational current (Ie)
2.4 A
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
3 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
2.4 A
Rated operational current (Ie) at AC-51
2.4 A
Rated operational current (Ie) at AC-53A - max
2.4 A
Rated operational current (Ie) at AC-53A - min
0.15 A
Rated operational current (Ie) at DC-13, 24 V
2 A
Rated operational power at AC-3, 220/230 V, 50 Hz
0.37 kW
Rated operational power at AC-3, 380/400 V, 50 Hz
0.75 kW
Rated operational power at AC-53A, 380/400 V, 50 Hz
0.75 kW
Rated operational voltage
250 V AC/DC
42 - 550 V
Short-circuit protection rating
50 kA, 500 V AC: Fuse 16 A gG/gL, Short-circuit protective device, Type “1” coordination, Main conducting paths
50 kA, 415 V AC: PKM0-4, Short-circuit protective device, Type “1” coordination, Main conducting paths
15 kA, 415 V AC: PKM0-6,3, Short-circuit protective device, Type “1” coordination, Main conducting paths
Supply voltage
A1 - A2: 24 V DC (-20 - +25 %), UAUX, Control section, Input data
Switching level
-3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R)
< 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R)
19.2 - 30 V DC, Switching level "High", Actuating circuit (ON, L, R)

Contacts

Number of auxiliary contacts (normally closed contacts)
1
Number of auxiliary contacts (normally open contacts)
1
Number of contacts (change-over contacts)
1

Safety

Explosion safety category for dust
ATEX dust-ex-protection, II (2) G [Ex e] [Ex d] [Ex px]
ATEX dust-ex-protection, II (2) D [Ex t] [Ex p]
Safe isolation
500 V AC; Between supply, control, and switching voltages; According to EN50178
300 V AC, Between feedback signal output and switch voltage, According to EN 50178
300 V AC; Between supply, control, and switching voltages; According to EN50178
500 V AC, Between feedback signal output and switch voltage, According to EN 50178
Safety parameter (EN ISO 13849-1)
316 years; MTTFD
Safety parameter (IEC 62061)
Λsu [FIT]: 1550
SIL: 2
Λdd [FIT]: 314
97.9 %, SFF
Λsd [FIT]: 0
Λdu [FIT]: 47.2
86,9 %, DC

Design verification

Equipment heat dissipation, current-dependent Pvid
2 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0.7 W
Rated operational current for specified heat dissipation (In)
2.4 A
Static heat dissipation, non-current-dependent Pvs
1 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 170099 Low-voltage industrial controls and switchgear (EC001037)
Feature Name Feature Value
Type of motor starter (EF009598) Direct starter
With short-circuit release (EF006691) No
Rated control supply voltage AC 50 Hz (EF003978) 0 V
Rated control supply voltage AC 60 Hz (EF003979) 0 V
Rated control supply voltage DC (EF003980) 24 V
Voltage type for actuating (EF008242) DC
Rated operation power at AC-3, 230 V, 3-phase (EF009599) 0.37 kW
Rated operation power at AC-3, 400 V (EF001364) 0.75 kW
Rated power, 460 V, 60 Hz, 3-phase (EF009600) 0.736 kW
Rated power, 575 V, 60 Hz, 3-phase (EF009601) 0 kW
Rated operation current Ie (EF001443) 2.4 A
Rated operation current at AC-3, 400 V (EF009602) 2.4 A
Overload release current setting (EF002336) 0.18 A
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) 0 A
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) 0 A
Rated conditional short-circuit current, type 2, 230 V (EF009606) 0 A
Rated conditional short-circuit current, type 2, 400 V (EF009605) 0 A
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Ambient temperature, upper operating limit (EF009603) 60 °C
Temperature compensated overload protection (EF009604) Yes
Release class (EF006668) CLASS 10
Type of electrical connection of main circuit (EF006819) Spring clamp connection
Type of electrical connection for auxiliary- and control current circuit (EF006979) Spring clamp connection
Suitable for rail mounting (EF003972) Yes
With transformer (EF000278) No
Number of command positions (EF001372) 0
Suitable for emergency stop (EF001433) No
Coordination class according to IEC 60947-4-3 (EF012390) Class 1
Number of indicator lights (EF001965) 4
External reset possible (EF003426) Yes
With fuse (EF006693) No
Degree of protection (IP) (EF005474) IP20
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) No
Width (EF000008) 155 mm
Height (EF000040) 60 mm
Depth (EF000049) 160 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.