| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | e3d9d072-a7d2-418c-981f-19f9d328f8b9 Italy |
| Simplified SCIP | 2dbcd25a-45e9-4d6e-9a19-42a5c3b2aec5 Poland |
| 46ef68f8-03b2-445f-be55-971b8857f4c2 Belgium | |
| 31996ba0-930e-4c2c-9250-efa7784c88d3 Germany | |
| 8b4662b8-ba23-4fa4-a495-7aa30ffd7dc8 Sweden | |
| 824bbdfb-265a-450f-9ebf-5ab45ea8b452 Germany | |
| f13b16d6-a8b4-4f30-b98f-956a81ecb02f Hungary | |
| a879a7d6-bf54-4d6e-b9b8-acdd91c2a36a France | |
| d918e53e-df49-41a6-8587-79aaf818f0fb Spain | |
| cdd46b91-84ae-4e6e-bf6a-9ca2ba09fbb6 Czech Republic | |
| 91e244e7-6333-4883-b239-5a233ff97ecc Croatia | |
| 8442cab1-e482-4764-ab47-6fa158051057 Poland | |
| 4934ba4f-28dd-484e-8e64-f4afe0dea634 Netherlands | |
| 735450ed-3d29-4145-99e1-0c430e7c6cab Hungary | |
| 7af9964d-1cc0-4531-b9f8-5a365cecae07 Portugal | |
| 7aaac4ec-7d66-4a0a-904d-c60b23a70d80 Greece | |
| 223617d6-03da-45e8-935c-a259f2a07d15 Estonia | |
| e2ee8d7b-c044-429b-ae37-7c71572aa9f1 France | |
| 9ac10248-666e-4b84-a3aa-85577d03f17d Poland | |
| 2e2ff34c-2e74-4b4e-aa3d-d5996b2cfbbb Sweden | |
| 221948c7-bf69-46ae-82a2-4d838c9a7b20 Bulgaria | |
| 68b01b55-da46-4368-893a-85f4217295ff Germany | |
| 30928c7a-852f-4b53-bf62-ade76082f2e5 Belgium | |
| ee478b51-0443-4100-8486-53d8513c2a10 Denmark | |
| c0201653-2604-44ae-b5dc-38d8e642f31c Germany | |
| 31d6c4d4-abcc-40f4-a4bc-beb855804506 Finland | |
| 16e3139a-2491-42f6-bec4-d88006caf5a5 Germany | |
| 78e53097-420d-497e-9dbe-353e66d7bfc7 Norway | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644577339 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 558 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 81 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 96 kg |
| Package Level 1 EAN | 8015644577339 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 12000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 90 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1250 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E3H 1250 PR121/P-LSI In1250A 4p W MP - ABB - E3H1250 - 1SDA056393R1 | 90 Kbytes |
![]() |
| E3H1250 1SDA056393R1 ABB E3H 1250 PR121/P-LSI In 1250A 4p W MP | 82 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.