Product successfully added to your shopping cart
1SDA072330R1
ABB
1
E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP
Low-voltage industrial components > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax" > E2.2
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 47ff4548-721e-41da-8920-24d82f39f738 Italy |
| Simplified SCIP | 3a68ce32-eef2-4424-b927-a962b7f37d9e Sweden |
| 46d8484a-03e3-464e-9b20-b819f16ede64 Spain | |
| 5030df7d-efe0-4492-b888-ac09331be598 Estonia | |
| 0f8c4ad6-d20d-43b9-bd06-dad3e56eefbc Poland | |
| 5030df7d-efe0-4492-b888-ac09331be598 Estonia | |
| 46536f55-bea4-4347-aa5e-b5888e977452 Poland | |
| aeb52a1d-5f77-4fe1-8277-b52dce4ec005 France | |
| 13126262-d4d9-4794-91c9-1dbdb01e30f0 Sweden | |
| 6720a513-166f-4e20-b518-1d7254e5ac9b Germany | |
| 70a230ee-f7ea-444b-8794-516e206bf347 Hungary | |
| f62c3948-f110-42bf-af44-c0d87ffd94a4 Germany | |
| e6aa4d1e-6377-498c-88a5-00747b079078 France | |
| 46d8484a-03e3-464e-9b20-b819f16ede64 Spain | |
| 1cabc9d3-8d9d-4662-8033-3cd934806ae6 Belgium | |
| eb70bbec-3641-459d-9621-e60e5d9ad0b8 Denmark | |
| f6d74eee-0a64-4d21-882a-0b298096333c Germany | |
| bd74f87c-9b7e-40ed-9b3e-6b4ab05b3b3e Finland | |
| 5b989921-1ea9-4748-b1ab-5c7023a6353d Germany | |
| 7f323d54-e5c5-4c84-b72e-b89adf09ed80 Bulgaria | |
| cbded102-30ad-4252-8127-2ed9bfb5e23c Belgium | |
| 879269e7-bc1a-46fd-a94c-93fe1512c159 Norway | |
| 70a230ee-f7ea-444b-8794-516e206bf347 Hungary | |
| eb70bbec-3641-459d-9621-e60e5d9ad0b8 Denmark | |
| f8f99b05-f88c-40c3-bc3e-891e549560ee Poland | |
| 37aedb20-66af-4b80-afed-00d2acb0c3ab Greece | |
| 46536f55-bea4-4347-aa5e-b5888e977452 Poland | |
| 387e43ea-2103-484d-bdcd-d2043ca860c9 Czech Republic | |
| f6fa8db2-4e27-420c-92f0-5dbc26c7ec18 Germany | |
| 5b989921-1ea9-4748-b1ab-5c7023a6353d Germany | |
| bde05fe2-44eb-4e0c-abbf-ee8fdeaa111c Croatia | |
| 3a68ce32-eef2-4424-b927-a962b7f37d9e Sweden | |
| f6fa8db2-4e27-420c-92f0-5dbc26c7ec18 Germany | |
| cbded102-30ad-4252-8127-2ed9bfb5e23c Belgium | |
| aeb52a1d-5f77-4fe1-8277-b52dce4ec005 France | |
| 879269e7-bc1a-46fd-a94c-93fe1512c159 Norway | |
| e6aa4d1e-6377-498c-88a5-00747b079078 France | |
| f6d74eee-0a64-4d21-882a-0b298096333c Germany | |
| 8b626831-ad07-4aff-b434-83554c86e2b6 Portugal | |
| bd74f87c-9b7e-40ed-9b3e-6b4ab05b3b3e Finland | |
| bde05fe2-44eb-4e0c-abbf-ee8fdeaa111c Croatia | |
| b350fea3-1089-46ae-a865-c585d587fc41 Netherlands | |
| de352dfd-1efc-4f03-9e5b-dd1d362decc4 Hungary | |
| 387e43ea-2103-484d-bdcd-d2043ca860c9 Czech Republic | |
| 7f323d54-e5c5-4c84-b72e-b89adf09ed80 Bulgaria | |
| f62c3948-f110-42bf-af44-c0d87ffd94a4 Germany | |
| 6720a513-166f-4e20-b518-1d7254e5ac9b Germany | |
| de352dfd-1efc-4f03-9e5b-dd1d362decc4 Hungary | |
| 13126262-d4d9-4794-91c9-1dbdb01e30f0 Sweden | |
| 1cabc9d3-8d9d-4662-8033-3cd934806ae6 Belgium | |
| b350fea3-1089-46ae-a865-c585d587fc41 Netherlands | |
| f8f99b05-f88c-40c3-bc3e-891e549560ee Poland | |
| 0f8c4ad6-d20d-43b9-bd06-dad3e56eefbc Poland | |
| 37aedb20-66af-4b80-afed-00d2acb0c3ab Greece | |
| 8b626831-ad07-4aff-b434-83554c86e2b6 Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2HREHAQ200A000000XX |
| EAN | 8015644761806 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644761806 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 176 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | Ekip G Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG EMAX 2 EN.pdf | 207 Mbytes |
|
| E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP - ABB - E2.2H1250 - 1SDA072330R1 | 95 Kbytes |
![]() |
| E2.2H1250 1SDA072330R1 ABB E2.2H 1250 Ekip G Hi-Touch LSIG 3p WMP | 74 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.