Product successfully added to your shopping cart
1SFL491001R8611
ABB
1
A185-30-11 CONTACTOR 3P 185A COIL 400-415Va
A185-30-11 400-415V 50Hz / 415-440V 60Hz Contactor
Service Breakers
Brand new product in its original packaging covered by the warranties and certifications provided by ABB
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Replacement Product ID (NEW) | 1SFL487002R1411 |
| Popular Downloads | |
| Data Sheet, Technical Information | 1SBC100192C0206 |
| Instructions and Manuals | 1SFC380003-89 |
| Dimensions | |
| Product Net Width | 111.5 mm |
| Product Net Depth / Length | 160 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 2.9 kg |
| Dimension Diagram | 53540923-7 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 200 A |
| (1000 V) 55 °C 200 A | |
| (1000 V) 70 °C 180 A | |
| (690 V) 40 °C 275 A | |
| (690 V) 55 °C 250 A | |
| (690 V) 70 °C 180 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 185 A |
| (440 V) 55 °C 185 A | |
| (500 V) 55 °C 170 A | |
| (690 V) 55 °C 170 A | |
| (1000 V) 55 °C 95 A | |
| (380 / 400 V) 55 °C 185 A | |
| (220 / 230 / 240 V) 55 °C 185 | |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A |
| (220 V) 3 Poles in Series, 40 °C 275 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A |
| (220 V) 3 Poles in Series, 40 °C 275 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 275 A |
| (220 V) 3 Poles in Series, 40 °C 275 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 90 kW |
| (440 V) 90 kW | |
| (500 V) 110 kW | |
| (690 V) 132 kW | |
| (380 / 400 V) 90 kW | |
| (220 / 230 / 240 V) 55 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 355 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1500 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 320 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 800 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1000 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1600 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 150 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 400 ... 415 V |
| 60 Hz 415 ... 440 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 8 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 5 ... 10 ms |
| Between Coil De-energization and NO Contact Opening 9 ... 13 ms | |
| Between Coil Energization and NC Contact Opening 8 ... 22 ms | |
| Between Coil Energization and NO Contact Closing 13 ... 27 ms | |
| Connecting Capacity Main Circuit | Bar 24 mm² |
| Rigid Al-Cable 25 ... 150 mm² | |
| Rigid Cu-Cable 6 ... 185 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 1 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 24 mm² |
| Rigid Al-Cable 25 ... 150 mm² | |
| Rigid Cu-Cable 6 ... 185 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | Flat type c/w screws and bolts |
| Tightening Torque | Main Circuit 18 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 250 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 50 hp |
| (208 V AC) Three Phase 50 hp | |
| (220 ... 240 V AC) Three Phase 60 hp | |
| (440 ... 480 V AC) Three Phase 125 hp | |
| (550 ... 600 V AC) Three Phase 150 hp | |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 156 A |
| (550 ... 600 V AC) Three Phase 144 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| BV Certificate | 09826/C0 BV |
| CB Certificate | SE-69489 |
| CQC Certificate | CQC2002010304011010 |
| CQC2009010304353525 | |
| CSA Certificate | 314004 |
| Declaration of Conformity - CCC | 2020980304001633 |
| 2020980304001040 | |
| Declaration of Conformity - CE | 2CMT2015-005436 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| DNV Certificate | DNV_E-12191 |
| GL Certificate | GL_15529-00HH |
| LOVAG Certificate | SE9837127 |
| LR Certificate | LR_12-70003 |
| RINA Certificate | ELE060313XG/001 |
| RMRS Certificate | RMRS_12-03683-315 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 178 mm |
| Package Level 1 Depth / Length | 232 mm |
| Package Level 1 Height | 167 mm |
| Package Level 1 Gross Weight | 3.5 kg |
| Package Level 1 EAN | 7320500209691 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Norway) | 4115138 |
| E-Number (Sweden) | 3227867 |
| Title: | Size: | Type: |
|---|---|---|
| PDF CIRCUIT BREAKERS TMAX XT.pdf | 26 Mbytes |
|
| 1SFL491001R8611 EN_1SFL491001R8611.pdf | 217 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.