3VL4125-2KN30-0AA0 SIEMENS circuit breaker VL400 UL type JG (cat no. HJX3B250) non-interchangeable frame, wi.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3VL4125-2KN30-0AA0 SIEMENS circuit breaker VL400 UL type JG (cat no. HJX3B250) non-interchangeable frame, wi..

3VL4125-2KN30-0AA0

SIEMENS

circuit breaker VL400 UL; type JG (cat no. HJX3B250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=< 250A, rated current II=1250...2500A short-circuit protection IR=250A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > Moulded Case Circuit Breakers 3VL SENTRON

* Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



ETIM: EC000228 - Power circuit-breaker for trafo/generator/installation protection

Value Unit
Rated voltage (EF003977) -V
Type of control element (EF006976) -
Rated permanent current Iu (EF001389) 250.0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz (EF007048) 70.0kA
Overload release current setting (EF002336) ['250', '250']A
Adjustment range short-term delayed short-circuit release (EF007129) ['-', '-']A
Adjustment range undelayed short-circuit release (EF007131) ['1250', '2500']A
Integrated earth fault protection (EF007296) false
Type of electrical connection of main circuit (EF006819) Other
Device construction (EF008240) Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting (EF007250) true
DIN rail (top hat rail) mounting optional (EF008904) true
Number of auxiliary contacts as normally closed contact (EF001377) 0
Number of auxiliary contacts as normally open contact (EF001376) 0
Number of auxiliary contacts as change-over contact (EF003531) 0
With switched-off indicator (EF007006) false
With under voltage release (EF007518) false
Number of poles (EF001391) 3
Position of connection for main current circuit (EF006671) Front side
Complete device with protection unit (EF008906) true
Motor drive integrated (EF006697) false
Motor drive optional (EF007386) true
Degree of protection (IP) (EF005474) IP20


Product
Article Number (Market Facing Number)3VL4125-2KN30-0AA0
Product Descriptioncircuit breaker VL400 UL; type JG (cat no. HJX3B250) non-interchangeable frame, with circuit breaker approval acc. to UL 489 high breaking capacity 3-pole, NEMA rating 65kA/480V, (molded case circuit breaker) Electronic Trip Unit TM, LI TA=40°C In=< 250A, rated current II=1250...2500A short-circuit protection IR=250A Electronic Trip Unit for line protection without connection accessories without auxiliary release without auxiliary/alarm switch
Product familyNot available
Product Lifecycle (PLM)PM400:Phase Out Started
PLM Effective DateProduct phase-out since: 01.04.2019
Notes
Sucessor:Successor portfolio 3VA; further information via www.siemens.com/3VA
Price data
Price Group12N
Surcharge for Raw MaterialsNone
Metal FactorLBO-----
Delivery information
Export Control RegulationsECCN : EAR99 / AL : N
Standard lead time ex-works5 Day/Days
Net Weight (kg)5,700 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension169,00 x 372,00 x 187,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EANNot available
UPC783643608955
Commodity Code85362090
LKZ_FDB/ CatalogIDLV10.1
Product Group3742
Group CodeP360
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 25.09.2006
Product classC: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
VersionClassification
eClass627-37-04-09
eClass7.127-37-04-09
eClass827-37-04-09
eClass927-37-04-09
eClass9.127-37-04-09
ETIM4EC000228
ETIM5EC000228
ETIM6EC000228
ETIM7EC000228
UNSPSC1539-12-16-01

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.