ANUNCIAR
3RK1908-1AA00-0BP0 SIEMENS 3DI/LC module (connection terminals) for ET 200SP motor starter View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3RK1908-1AA00-0BP0 SIEMENS 3DI/LC module (connection terminals) for ET 200SP motor starter

3RK1908-1AA00-0BP0

SIEMENS

3DI/LC module (connection terminals) for ET 200SP motor starter

More details


CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

Total: $124.56
Unit price: $124.56
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

3DI/LC module (connection terminals) for ET 200SP motor starter
product brand nameSIMATIC
product categoryAccessories
product designation3DI/LC control module
design of the productAccessories
product type designationET 200SP
General technical data
● product functionAccessories
● product function with 24 V sensor supply short-circuit protectionYes
diagnostics function short-circuit detectionYes
display version for diagnostic function: Status display transmission channel channel status LEDYes
● noteGreen LED
degree of pollution2
protection class IPIP20
shock resistance6g / 11 ms
vibration resistance15 mm to 6 Hz; 2g to 500 Hz
Substance Prohibitance (Date)04/15/2016
product function short circuit protectionYes
Inputs/ Outputs
product function
● digital inputs parameterizableYes
● at the standard inputs at rated input voltage parameterizable input delay timeNo
input delay time at the standard inputs
● for signal <0> to <1> at rated input voltage10 ... 15 ms
● for signal <1> to <0> at rated input voltage10 ... 15 ms
number of digital inputs4
● noteInputs 1-3 parameterizable; input 4 (LC) for local control
digital input version type 1 acc. to IEC 61131Yes
value range of the input voltage at digital input for signal <0> detection-30 ... +5 V
value range of the input voltage at digital input for signal <1> detection+15 ... +30 V
input current at digital input for signal <1> typical9 mA
type of output voltage for sensor supplyDC
output voltage for sensor supply minimum19.2 V
output current for sensor supply at 60 °C maximum0.1 A
wire length of sensor maximum30 m
Installation/ mounting/ dimensions
mounting positionvertical, horizontal, flat
fastening methodCan be plugged onto motor starters
height54.5 mm
width30 mm
depth42.3 mm
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 ... +60 °C
● during storage-40 ... +70 °C
● during transport-40 ... +70 °C
relative humidity during operation10 ... 95 %
air pressure according to SN 31205900 ... 1 060 hPa
Connections/ Terminals
type of electrical connection for auxiliary and control circuitspring-loaded terminals (push-in)
connectable conductor cross-section for auxiliary contacts
● solid or stranded0.2 ... 1.5 mm²
● finely stranded with core end processing0.25 ... 1.5 mm²
● finely stranded without core end processing0.2 ... 1.5 mm²
AWG number as coded connectable conductor cross section for auxiliary contacts24 ... 16
shape of the screwdriver tipSlot
size of the screwdriver tipStandard screwdriver 0.6 mm x 3.5 mm
Certificates/ approvals

Downloads and manuals

General Product ApprovalEMCDeclaration of Conformity

CSA

Confirmation

UL

EAC

RCM

EC/EU-Declaration of Conformity

Test CertificatesMarine / Shippingother

Type Test Certificates/Test Report

ABS (American Bureau of Shipping)

BV / Bureau Veritas

DNV / Det Norske Veritas

LR (Lloyds Register)

Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Cax online generator
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
last modified:1/6/2021
Date
5/12/2022
Subject to change without notice
© Copyright Siemens 2022


Additional data

Product
Article Number (Market Facing Number)3RK1908-1AA00-0BP0
Product Description3DI/LC module (connection terminals) for ET 200SP motor starter
Product familyET 200SP motor starters
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group42D / 42D
Surcharge for Raw MaterialsNone
Metal FactorNone
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works1 Day/Days
Net Weight (kg)0,047 Kg
Packaging Dimension60,00 x 77,00 x 50,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4047621012209
UPC804766246982
Commodity Code85371098
LKZ_FDB/ CatalogIDCC-IC10
Product Group3724
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 15.04.2016
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead monoxide (lead oxide)

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
VersionClassification
eClass627-37-09-05
eClass7.127-37-09-05
eClass827-37-09-05
eClass927-37-09-05
eClass9.127-37-09-05
ETIM5EC001037
ETIM6EC001037
ETIM7EC001037
ETIM8EC001037

ETIM data

ETIM: EC001037 - Motor starter/Motor starter combination

Value Unit
Ambient temperature, upper operating limit (EF009603) -°C
Rated control supply voltage Us at AC 50HZ (EF003978) -V
Supporting protocol for other bus systems (EF003062) -
Rated control supply voltage Us at AC 60HZ (EF003979) -V
Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) -A
Rated operation current at AC-3, 400 V (EF009602) -A
Rated power, 575 V, 60 Hz, 3-phase (EF009601) -kW
Supporting protocol for PROFINET IO (EF007525) -
Number of command positions (EF001372) -
Number of indicator lights (EF001965) -
Supporting protocol for LON (EF003017) -
Supporting protocol for DeviceNet (EF003059) -
Supporting protocol for DeviceNet Safety (EF007520) -
Rated conditional short-circuit current, type 2, 230 V (EF009606) -A
Rated operation power at AC-3, 400 V (EF001364) -kW
Supporting protocol for INTERBUS (EF003054) -
External reset possible (EF003426) -
Rated control supply voltage Us at DC (EF003980) -V
Supporting protocol for INTERBUS-Safety (EF006662) -
With fuse (EF006693) -
Rated operation current Ie (EF001443) -A
Supporting protocol for TCP/IP (EF003050) -
Supporting protocol for ASI (EF003051) -
Supporting protocol for PROFIBUS (EF003052) -
Supporting protocol for SUCONET (EF003060) -
Supporting protocol for EtherNet/IP (EF007521) -
Supporting protocol for Foundation Fieldbus (EF007522) -
Rated operation power at AC-3, 230 V, 3-phase (EF009599) -kW
Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) -A
Rated conditional short-circuit current, type 2, 400 V (EF009605) -A
Degree of protection (NEMA) (EF011959) -
Temperature compensated overload protection (EF009604) -
Supporting protocol for CAN (EF003053) -
Type of electrical connection of main circuit (EF006819) -
Supporting protocol for SafetyBUS p (EF007527) -
Supporting protocol for Modbus (EF003057) -
Number of auxiliary contacts as normally open contact (EF001376) -
Suitable for emergency stop (EF001433) -
Supporting protocol for Data-Highway (EF003058) -
Rail mounting possible (EF003972) -
Release class (EF006668) -
Supporting protocol for PROFIsafe (EF007526) -
Rated power, 460 V, 60 Hz, 3-phase (EF009600) -kW
Coordination class according to IEC 60947-4-3 (EF012390) -
Supporting protocol for AS-Interface Safety at Work (EF007519) -
Supporting protocol for SERCOS (EF006657) -
Supporting protocol for PROFINET CBA (EF007524) -
Voltage type for actuating (EF008242) -
Number of auxiliary contacts as normally closed contact (EF001377) -
Overload release current setting (EF002336) -A
Type of motor starter (EF009598) Other
With short-circuit release (EF006691) true
Type of electrical connection for auxiliary- and control current circuit (EF006979) Other
With transformer (EF000278) false
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 30.0mm
Height (EF000040) 54.5mm
Depth (EF000049) 42.3mm



Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.