Product successfully added to your shopping cart
3RK1908-0AP00-0AP0
SIEMENS
1
Base unit (BU30-MS1) For ET 200SP motor starter With infeed 24 V and 500 V Incl. infeed bus cover
Low-voltage industrial components > Motor starter/Motor starter combination
CONTROL AND CONTACTORS > AS-Interface switchgear, SIMOCODE
Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product | |||||||||||||||||||||||||||||||
| Article Number (Market Facing Number) | 3RK1908-0AP00-0AP0 | ||||||||||||||||||||||||||||||
| Product Description | Base unit (BU30-MS1) For ET 200SP motor starter With infeed 24 V and 500 V Incl. infeed bus cover | ||||||||||||||||||||||||||||||
| Product family | ET 200SP motor starters | ||||||||||||||||||||||||||||||
| Product Lifecycle (PLM) | PM300:Active Product | ||||||||||||||||||||||||||||||
| Price data | |||||||||||||||||||||||||||||||
| Region Specific PriceGroup / Headquarter Price Group | 42D / 42D | ||||||||||||||||||||||||||||||
| Surcharge for Raw Materials | None | ||||||||||||||||||||||||||||||
| Metal Factor | None | ||||||||||||||||||||||||||||||
| Delivery information | |||||||||||||||||||||||||||||||
| Export Control Regulations | AL : N / ECCN : N | ||||||||||||||||||||||||||||||
| Standard lead time ex-works | 30 Day/Days | ||||||||||||||||||||||||||||||
| Net Weight (kg) | 0,170 Kg | ||||||||||||||||||||||||||||||
| Packaging Dimension | 57,00 x 219,00 x 86,00 | ||||||||||||||||||||||||||||||
| Package size unit of measure | MM | ||||||||||||||||||||||||||||||
| Quantity Unit | 1 Piece | ||||||||||||||||||||||||||||||
| Packaging Quantity | 1 | ||||||||||||||||||||||||||||||
| Additional Product Information | |||||||||||||||||||||||||||||||
| EAN | 4047621021300 | ||||||||||||||||||||||||||||||
| UPC | 804766246944 | ||||||||||||||||||||||||||||||
| Commodity Code | 85371098 | ||||||||||||||||||||||||||||||
| LKZ_FDB/ CatalogID | CC-IC10 | ||||||||||||||||||||||||||||||
| Product Group | 3724 | ||||||||||||||||||||||||||||||
| Group Code | R711 | ||||||||||||||||||||||||||||||
| Country of origin | Czech Republic | ||||||||||||||||||||||||||||||
| Compliance with the substance restrictions according to RoHS directive | Since: 15.04.2016 | ||||||||||||||||||||||||||||||
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | ||||||||||||||||||||||||||||||
| WEEE (2012/19/EU) Take-Back Obligation | Yes | ||||||||||||||||||||||||||||||
| REACH Art. 33 Duty to inform according to the current list of candidates |
| ||||||||||||||||||||||||||||||
| Classifications | |||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||
| Value | Unit | |
|---|---|---|
| Supporting protocol for ASI (EF003051) | - | |
| Supporting protocol for EtherNet/IP (EF007521) | - | |
| Temperature compensated overload protection (EF009604) | - | |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | - | |
| Rated conditional short-circuit current, type 1, 600 Y/347 V (EF009608) | - | A |
| Rated power, 460 V, 60 Hz, 3-phase (EF009600) | - | kW |
| Supporting protocol for Foundation Fieldbus (EF007522) | - | |
| Supporting protocol for Data-Highway (EF003058) | - | |
| Number of indicator lights (EF001965) | - | |
| Rated control supply voltage Us at AC 60HZ (EF003979) | - | V |
| Rated conditional short-circuit current, type 2, 400 V (EF009605) | - | A |
| Rated operation power at AC-3, 230 V, 3-phase (EF009599) | - | kW |
| Number of command positions (EF001372) | - | |
| Supporting protocol for INTERBUS (EF003054) | - | |
| Supporting protocol for DeviceNet (EF003059) | - | |
| Rated control supply voltage Us at AC 50HZ (EF003978) | - | V |
| Rated control supply voltage Us at DC (EF003980) | - | V |
| With fuse (EF006693) | - | |
| Supporting protocol for DeviceNet Safety (EF007520) | - | |
| Supporting protocol for PROFINET CBA (EF007524) | - | |
| Number of auxiliary contacts as normally open contact (EF001376) | - | |
| Supporting protocol for LON (EF003017) | - | |
| Supporting protocol for TCP/IP (EF003050) | - | |
| Supporting protocol for SUCONET (EF003060) | - | |
| Supporting protocol for other bus systems (EF003062) | - | |
| Supporting protocol for INTERBUS-Safety (EF006662) | - | |
| Degree of protection (NEMA) (EF011959) | - | |
| Rated operation power at AC-3, 400 V (EF001364) | - | kW |
| Overload release current setting (EF002336) | - | A |
| Rated conditional short-circuit current, type 1, 480 Y/277 V (EF009607) | - | A |
| Supporting protocol for Modbus (EF003057) | - | |
| Supporting protocol for CAN (EF003053) | - | |
| External reset possible (EF003426) | - | |
| Release class (EF006668) | - | |
| Rated power, 575 V, 60 Hz, 3-phase (EF009601) | - | kW |
| Ambient temperature, upper operating limit (EF009603) | - | °C |
| Coordination class according to IEC 60947-4-3 (EF012390) | - | |
| Number of auxiliary contacts as normally closed contact (EF001377) | - | |
| Suitable for emergency stop (EF001433) | - | |
| Supporting protocol for PROFIBUS (EF003052) | - | |
| Supporting protocol for SERCOS (EF006657) | - | |
| Supporting protocol for PROFINET IO (EF007525) | - | |
| Supporting protocol for PROFIsafe (EF007526) | - | |
| Supporting protocol for SafetyBUS p (EF007527) | - | |
| Rated operation current at AC-3, 400 V (EF009602) | - | A |
| Rated conditional short-circuit current, type 2, 230 V (EF009606) | - | A |
| Rail mounting possible (EF003972) | - | |
| With short-circuit release (EF006691) | - | |
| Type of motor starter (EF009598) | Other | |
| Voltage type for actuating (EF008242) | DC | |
| Rated operation current Ie (EF001443) | 32 | A |
| Type of electrical connection of main circuit (EF006819) | Other | |
| Type of electrical connection for auxiliary- and control current circuit (EF006979) | Other | |
| With transformer (EF000278) | false | |
| Degree of protection (IP) (EF005474) | IP20 | |
| Width (EF000008) | 30.0 | mm |
| Height (EF000040) | 215.0 | mm |
| Depth (EF000049) | 75.0 | mm |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SIEMENS EN.pdf | 120 Mbytes |
|
| PDF CATALOGUE SIEMENS EN.pdf | 104 Mbytes |
|
| 3RK1908-0AP00-0AP0 3RK1908-0AP00-0AP0 EN_3RK1908-0AP00-0AP0.pdf | 332 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.