3LD2530-0TK01-0AB5 SIEMENS SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

3LD2530-0TK01-0AB5 SIEMENS SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power ..

3LD2530-0TK01-0AB5

SIEMENS

10

SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power / at AC-23 A at 400 V: 22 kW, installation in distribution boards, knob-operated mechanism, black, handle direct at the switch

INTERR. PPAL. 3 POLES IU=63, P/AC-23A WITH 400V=22KW FIXATION BASED FIXING PROFILE/2 HOLES MULETILLA NETAMA LOGO JANSSEN CONSISTS OF 10 INTERR: ( ** ATTENTION : Price per 1 Unit and Minimum Quantity / Multiplo of Order 10 Units ** )

More details


POWER DISTRIBUTION AND LOW VOLTAGE SWITCHGEAR > SWITCHES-DISCONNECTORS

Brand new product in its original packaging covered by the warranties and certifications provided by SIEMENS

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



Technical data

SENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power / at AC-23 A at 400 V: 22 kW, installation in distribution boards, knob-operated mechanism, black, handle direct at the switch
Model
product brand nameSENTRON
product designation3LD Switch disconnector
design of the productMain switch
display version / for switch position indicator manual operation1 ON - 0 OFF
design of the actuating elementselector switch
design of handleknob-operated mechanism, black
type of the driving mechanism / motor driveNo
General technical data
number of poles3
type of devicefixed mounting
type of switchDIN-rail mounting
size of switch disconnector3
mechanical service life (switching cycles) / typical100 000
electrical endurance (switching cycles)
● at AC-23 A / at 690 V6 000
I2t value / with closed switch / at 690 V / for combination switch + gG fuse / maximum21 kA2.s
let-through I2t value / with closed switch / at 440 V / for combination switch + gG fuse / maximum21 kA2.s
operating frequency / maximum50 1/h
Voltage
insulation voltage / rated value690 V
surge voltage resistance / rated value6 kV
Protection class
protection class IPIP40
protection class IP / on the frontIP40
Dissipation
power loss [W]
● for rated value of the current / at AC / in hot operating state / per pole4.5 W
● per conductor / typical5 W
Current
operational current
● at 40 °C / rated value63 A
● at 45 °C / rated value63 A
● at 50 °C / rated value63 A
● at 55 °C / rated value63 A
● at AC / rated value63 A
● at AC-23 A / at 400 V / rated value43 A
● at AC-21 / at 690 V / rated value63 A
● at AC-21 A / at 240 V / rated value63 A
● at AC-21 A / at 440 V / rated value63 A
operational current / of upstream fuse / rated value63 A
let-through current / with closed switch
● at 440 V / for combination switch + gG fuse / maximum6 kA
● at 690 V / for combination switch + gG fuse / maximum permissible6 kA
Main circuit
operating power
● at AC-23 A / at 240 V / rated value11 kW
● at AC-23 A / at 400 V / rated value22 kW
● at AC-23 A / at 440 V / rated value22 kW
● at AC-23 A / at 690 V / rated value19 kW
● at AC-3 / at 240 V / rated value11 kW
● at AC-3 / at 400 V / rated value19 kW
● at AC-3 / at 690 V / rated value15 kW
operational current / rated value63 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts0
number of NC contacts / for auxiliary contacts0
number of NO contacts / for auxiliary contacts0
operating voltage / of auxiliary contacts / at AC / maximum500 V
continuous current / of the auxiliary contact / rated value10 A
insulation voltage / of the auxiliary switch / rated value500 V
Suitability
suitability for use
● main switchYes
● switch disconnectorYes
● EMERGENCY OFF switchNo
● safety switchYes
● maintenance/repair switchYes
Appearance
color / of the actuating elementblack
Product details
product feature
● can be locked into OFF positionYes
number of bracket locks / maximum2
hasp thickness / of the bracket locks / minimum4 mm
hasp thickness / of the bracket locks / maximum6 mm
product extension / optional
● motor driveNo
● voltage triggerNo
Short circuit
conditional short-circuit current / with line-side fuse protection
● at 690 V / by gG fuse / rated value50 kA
according UL
operational current / at AC / according to UL 508/UL 60947-4-1 / rated value63 A
operating voltage / at AC / at 50/60 Hz / according to UL 508/UL 60947-4-1 / rated value600 V
active power [hp] / at AC / at 480 V / according to UL 508/UL 60947-4-1 / rated value40
active power [hp] / at AC / at 600 V / according to UL 508/UL 60947-4-1 / rated value50
short-time withstand current (SCCR) / at 600 V / according to UL 508/UL 60947-4-15 kA
continuous current / of upstream fuse / according to UL / rated value175 A
type of fuse / according to ULRK5
Number
number of connectable NC contacts / for auxiliary contacts / attachable / maximum2
number of connectable NO contacts / for auxiliary contacts / attachable / maximum4
number of connectable CO contacts / for auxiliary contacts / attachable / maximum0
Connections
AWG number / as coded connectable conductor cross section / solid
● maximum6
● minimum14
type of connectable conductor cross-sections / for copper conductor
● solid1x (2,5...35mm²)
● finely stranded / with core end processing1x (2.5...16 mm²)
● stranded1x (2,5..35mm²)
type of connectable conductor cross-sections / for auxiliary contacts
● solid2x (0.75 ... 2.5 mm²), 1x 4 mm²
● finely stranded / with core end processing2x (0.75 ... 1.5 mm²), 1x 2.5 mm²
● stranded2x (0.75 ... 2.5 mm²), 1x 4 mm²
type of electrical connection
● for main current circuitbox terminal
● for auxiliary contactsconnection terminals
Requirements
design of the fuse link
● for short-circuit protection of the main circuit / requiredfuse gL/gG: 63 A
● for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Mechanical Design
height82 mm
width63 mm
depth90 mm
fastening methodBuilt-in unit fixed-mounted version
fastening method
● 4-hole front mountingNo
● front mounting with central attachmentNo
● rail mountingYes
net weight2 831 g
Environmental conditions
ambient temperature / during operation
● minimum-25 °C
● maximum55 °C
ambient temperature / during storage / minimum-25 °C

Downloads and manuals

General Product Approval

CSA

Confirmation

CCC

UL

VDE

Miscellaneous

General Product ApprovalDeclaration of ConformityTest CertificatesMarine / Shippingother

EAC

UK Declaration of Conformity

EC/EU-Declaration of Conformity

Special Test Certificate

LR (Lloyds Register)

Environmental Confirmations

other

Miscellaneous

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
CAx-Online-Generator
Tender specifications
Date
5/2/2022


Additional data

Product
Article Number (Market Facing Number)3LD2530-0TK01-0AB5
Product DescriptionSENTRON, Switch disconnector 3LD, main switch, 3-pole, Iu: 63 A, Operating power / at AC-23 A at 400 V: 22 kW, installation in distribution boards, knob-operated mechanism, black, handle direct at the switch
Product familyNot available
Product Lifecycle (PLM)PM300:Active Product
Price data
Region Specific PriceGroup / Headquarter Price Group12R / 1CL
Surcharge for Raw MaterialsNone
Metal FactorLAO-----
Delivery information
Export Control RegulationsECCN : N / AL : N
Standard lead time ex-works80 Day/Days
Net Weight (kg)2,760 Kg
Packaging Dimension150,00 x 201,00 x 155,00
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Minimum order quantity10
Additional Product Information
EAN4011209547889
UPCNot available
Commodity Code85365080
LKZ_FDB/ CatalogIDLV10.1
Product Group5887
Group CodeP360
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveGiven
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates
There is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly.
Classifications
Not available

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.