Product successfully added to your shopping cart
STEP-UPS/24DC/24DC/3
2868703
PHOENIX_CONTACT
1
Uninterruptible power supply
Uninterruptible power supply with integrated battery module. The STEP-BAT/LIPO/18.5 DC/1.4 AH battery module can be ordered separately.
Power Supplies (PS)
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| DC operation | |
| Input voltage | 24 V DC |
| Nominal input voltage range | 24 V DC |
| Input voltage range | 22.5 V DC ... 29.5 V DC |
| Voltage type of supply voltage | DC |
| Buffer period | 50 min. (1 A) |
| 25 min. (2 A) | |
| 17 min. (3 A) | |
| Rotary selector switch | Service |
| | |
| 5 min. | |
| 10 min. | |
| 20 min. | |
| Current consumption | 4.7 A |
| < 30 mA | |
| < 0.5 A (Charging (ICharge = max, IOut = 0)) | |
| Fixed backup threshold | < 22.5 V |
| Variable connect threshold | 1 V / 1 s |
| Typical response time | < 0.5 s |
| Input fuse | 7 A (slow-blow, internal) |
| Efficiency | > 98 % (Mains operation, with charged energy storage) |
| > 95 % (Battery operation) | |
| Nominal output voltage | 24 V DC |
| Nominal output current (IN) | 3 A (0 °C ... 40 °C) |
| Output current limit | In mains mode according to connected upstream current limiting device |
| > 4 A (Battery operation) | |
| POWER BOOST (IBoost) | 4 A (0 °C ... 35 °C) |
| Bridging time | 900 s |
| Derating | 35 °C ... 40 °C (5 %/K) |
| Output power | 72 W |
| Power dissipation | 0.6 W (Mains operation) |
| 2 W (Mains operation) | |
| 4.4 W (Mains operation) | |
| 1.1 W (Battery operation) | |
| 3.8 W (Battery operation) | |
| 10 W (Battery operation) | |
| Connection in series | no |
| Mains operation | |
| Nominal output voltage | 24 V DC |
| Output voltage range | 22.5 V DC ... 29.5 V DC (UOut= UIn- 0.3 V DC) |
| Output current Imax | 4 A (0 °C ... 35 °C) |
| Nominal output current (IN) | 3 A (0 °C ... 40 °C) |
| Battery operation | |
| Nominal output voltage | 24 V DC |
| Output voltage range | 23 V DC ... 26.5 V DC (UOut= UIn (t-1)) |
| Output current Imax | 4 A (0 °C ... 35 °C) |
| Nominal output current (IN) | 3 A (0 °C ... 40 °C) |
| Signal: Alarm | |
| Output description | Transistor |
| Signal: Battery charge | |
| Output description | Transistor |
| Signal: Battery mode | |
| Output description | Transistor |
| Nominal voltage UN | 18.5 V DC |
| End-of-charge voltage | 18.5 V DC ... 21 V DC |
| Charging current | 0.4 A |
| Nominal capacity | 1.4 Ah |
| Nominal capacity range | 1.4 Ah |
| Deep discharge protection | < 15 V DC |
| Battery technology | LIPO |
| Memory medium | Lithium polymer |
| Battery presence check (cyclic) | 60 s |
| Quality check of battery | yes, with each charge and cyclically once per month |
| IQ technology | no |
| Network management | No |
| Input | |
| Connection method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 6.5 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.6 Nm |
| Tightening torque max | 0.8 Nm |
| Output | |
| Connection method | Screw connection |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 6.5 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.6 Nm |
| Tightening torque max | 0.8 Nm |
| Signal | |
| Conductor cross section, rigid min. | 0.2 mm² |
| Conductor cross section, rigid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 6.5 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Types of signaling | LED |
| Signal output | |
| Signalization designation | Power In OK |
| Status display | LED |
| Note on status display | static on |
| Signal output: Switching output | |
| Signalization designation | Alarm |
| Status display | LED |
| Note on status display | static on |
| Signal output: Switching output | |
| Signalization designation | Battery charge |
| Status display | LED |
| Note on status display | flashing |
| Signal output: Switching output | |
| Signalization designation | Battery mode |
| Status display | LED |
| Note on status display | static on |
| Signal output | |
| Signalization designation | Overload |
| Status display | LED |
| Note on status display | flashing |
| Signal output | |
| Signalization designation | Service/Battery Error |
| Status display | LED |
| Note on status display | flashing |
| Product type | DC UPS |
| IQ technology | no |
| MTBF (IEC 61709, SN 29500) | > 1401000 h (40 °C) |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics | |
| Protection class | III |
| Degree of pollution | 2 |
| Width | 108 mm |
| Height | 90 mm |
| Depth | 61 mm |
| Installation dimensions | |
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 0 mm / 0 mm |
| Mounting type | DIN rail mounting |
| Assembly note | alignable: horizontally 0 mm, vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Housing material | Polycarbonate |
| Type of housing | Plastic |
| Foot latch material | POM (Polyoxymethylene) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | 0 °C ... 40 °C |
| Ambient temperature (storage/transport) | -20 °C ... 45 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz ... 150 Hz, 2.3g, 90 min. | |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
| UL approvals | UL Listed UL 508 |
| UL/C-UL Recognized UL 60950-1 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| EMC requirements for noise emission | EN 61000-6-3 |
| EN 61000-6-4 | |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EN 61000-6-2 | |
| Electrostatic discharge | |
| Standards/regulations | EN 61000-4-2 |
| Electrostatic discharge | |
| Contact discharge | 6 kV (Test Level 3) |
| Discharge in air | 8 kV (Test Level 3) |
| Comments | Criterion A |
| Electromagnetic HF field | |
| Standards/regulations | EN 61000-4-3 |
| Electromagnetic HF field | |
| Frequency range | 80 MHz ... 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 1 GHz ... 2 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 2 GHz ... 3 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Comments | Criterion A |
| Fast transients (burst) | |
| Standards/regulations | EN 61000-4-4 |
| Fast transients (burst) | |
| Input | 2 kV (Test Level 3 - asymmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Signal | 2 kV (Test Level 4 - asymmetrical) |
| Comments | Criterion A |
| Surge voltage load (surge) | |
| Standards/regulations | EN 61000-4-5 |
| Surge voltage load (surge) | |
| Input | 0.5 kV (Test Level 1 - symmetrical) |
| Output | 0.5 kV (Test Level 1 - symmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Comments | Criterion B |
| Conducted interference | |
| Standards/regulations | EN 61000-4-6 |
| Conducted interference | |
| I/O/S | asymmetrical |
| Frequency range | 0.15 MHz ... 80 MHz |
| Comments | Criterion A |
| Voltage | 10 V (Test Level 3) |
| Emitted interference | |
| Standards/regulations | EN 61000-6-3 |
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Criteria | |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOG PHOENIX PROTECTION EN .pdf | 27 Mbytes |
|
| PHOENIX CONTACT-2868703-STEP-UPS/24DC/24DC/3 | 130 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.