VAL-MS-T1/T2 1000DC-PV/2+V 2801160 PHOENIX CONTACT Lightning/surge arrester for 2-pos. isolated 1000 V DC vo.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-MS-T1/T2 1000DC-PV/2+V 2801160 PHOENIX CONTACT Lightning/surge arrester for 2-pos. isolated 1000 V DC vo..

VAL-MS-T1/T2 1000DC-PV/2+V

2801160

PHOENIX_CONTACT

Lightning/surge arrester for 2-pos. isolated 1000 V DC voltage systems, for DIN rail mounting, 3-pos. base element, three plug-in temperature-monitored protective elements, status message on each plug.

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $255.96
Unit price: $255.96

Quantity Price
1+$255.96
2+$236.79
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Dimensions

Height90 mm
Width53.4 mm
Depth65.5 mm
Horizontal pitch3 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)60g (Half sine/11 ms/3x XYZ)
Vibration (operation)7.5g (5-500 Hz/2.5 h/XYZ)

General

Standards/specificationsEN 50539-11 2013
IEC test classificationPV T1
PV T2
T1
I
EN typeT1
Number of portsOne
SPD failure behaviorOCM (Open-circuit mode)
Connection configurationY configuration
SPD designCombination type
Installation locationInside
AccessibilityAccessible
Installation location of the disconnect deviceInternal
Mounting typeDIN rail: 35 mm
Colorjet black RAL 9005
Housing materialPA 6.6-FR
PBT-FR
Pollution degree2
Distance between live and grounded parts8 mm
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Surge protection fault messageoptical

Additional descriptions

NoteThe device is intended for touch proof installation in a housing. Ensure that there is a gap of at least 8 mm between the active and grounded parts in the connection area.

Protective circuit DC voltage side (DC)

Maximum continuous operating voltage UCPV1050 V DC
Open circuit voltage UOCSTC≤ 875 V DC
Short-circuit current rating ISCPV1000 A
Continuous operating current ICPV< 20 µA
Rated load current IL80 A
Residual current IPE≤ 20 µA DC
≤ 350 A AC
Standby power consumption PC≤ 25 mVA
Nominal discharge current In(8/20) µs (L+) - (L-)15 kA
Nominal discharge current In(8/20) µs (L+) - PE15 kA
Nominal discharge current In(8/20) µs (L-) - PE15 kA
Maximum discharge current Imax(8/20) µs (L+) - (L-)40 kA
Maximum discharge current Imax(8/20) µs (L+) - PE40 kA
Maximum discharge current Imax(8/20) µs (L-) - PE40 kA
Impulse discharge current (10/350)˽µs, charge2.5 As
Impulse discharge current (10/350)˽µs, specific energy6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp5 kA
Impulse discharge current (10/350)˽µs, charge2.5 As
Impulse discharge current (10/350)˽µs, specific energy6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp5 kA
Impulse discharge current (10/350)˽µs, charge2.5 As
Impulse discharge current (10/350)˽µs, specific energy6.25 kJ/Ω
Impulse discharge current (10/350) µs, peak value limp5 kA
Total discharge current ITotal(8/20) µs40 kA
Total discharge current ITotal(10/350) µs5 kA
Voltage protection level Up(L+) - (L-)≤ 3.5 kV
Voltage protection level Up(L+) - PE≤ 3.5 kV
Voltage protection level Up(L-) - PE≤ 3.5 kV
Residual voltage Ures(L+) - (L-)≤ 3.5 kV (at In)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Residual voltage Ures(L+) - PE≤ 3.5 kV (at In)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Residual voltage Ures(L-) - PE≤ 3.5 kV (at In)
≤ 2.9 kV (at 5 kA)
≤ 3.2 kV (at 10 kA)
≤ 3.7 kV (at 20 kA)
≤ 4.1 kV (at 30 kA)
≤ 4.6 kV (at 40 kA)
Response time tA(L+) - (L-)≤ 25 ns
Response time tA(L+) - PE≤ 25 ns
Response time tA(L-) -PE≤ 25 ns
Insulation resistance Riso> 5 GΩ (at 500 V DC)

Connection data

Connection methodScrew connection
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.35 mm²
Conductor cross section AWG15 ... 2
10 ... 2 (UL)
Screw threadM5
Tightening torque4.5 Nm
30 lbf-in. (UL)
Stripping length16 mm
Connection methodBiconnect terminal blocks
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.16 mm²
Screw threadM5

UL specifications

SPD Type4 (for Type 2 photovoltaic applications)
Maximum continuous operating voltage MCOV (L+) - (L-)1050 V DC
Maximum continuous operating voltage MCOV (L+) - G1050 V DC
Maximum continuous operating voltage MCOV (L-) - G1050 V DC
Nom. voltage875 V AC
Mode of protection(L+) - (L-)
(L+) - G
(L-) - G
Power distribution system1
Voltage protection rating VPR (L+) - (L-)3 kV
Voltage protection rating VPR (L+) - G3 kV
Voltage protection rating VPR (L-) -G3 kV
Nominal discharge current In(L+) - (L-)20 kA
Nominal discharge current In(L+) - G20 kA
Nominal discharge current In(L-) - G20 kA

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.