PSR-SPP-120UC/URM/5X1/2X2 2981415 PHOENIX CONTACT Coupling relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSR-SPP-120UC/URM/5X1/2X2 2981415 PHOENIX CONTACT Coupling relay

PSR-SPP-120UC/URM/5X1/2X2

2981415

PHOENIX_CONTACT

Coupling relay

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey 2981415
Packing unit 1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 277 (C-6-2017)
GTIN4046356051675
Weight per Piece (excluding packing)135.880 g
Custom tariff number85364900
Country of originDE (Germany)

Dimensions

Width22.5 mm
Height114.5 mm
Depth112 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US120 V AC/DC -20 % ... +10 %
Rated control supply current IStyp. 11 mA
Power consumption at UStyp. 1.32 W
Inrush currenttyp. 600 mA (Δt = 200 µs at Us)
Typ. starting time with Ustyp. 20 ms (when controlled via A1)
Typical release timetyp. 20 ms (when controlled via A1)
Recovery time< 500 ms
Operating voltage display1 x green LED
Protective circuitSurge protection Varistor
Maximum switching frequency0.5 Hz

Output data

Contact type5 enabling current paths
2 confirmation current paths
Contact materialAgSnO2
Maximum switching voltage230 V AC/DC (Observe the load curve)
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A (N/O contact)
3 A (N/C contact)
Maximum inrush current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2
Interrupting rating (ohmic load) max.144 W (N/O contact, 24 V DC, τ = 0 ms)
288 W (N/O contact, 48 V DC, τ = 0 ms)
240 W (N/O contact, 60 V DC, τ = 0 ms)
110 W (N/O contact, 110 V DC, τ = 0 ms)
88 W (N/O contact, 220 V DC, τ = 0 ms)
1380 VA (N/O contact, 230 V AC, τ = 0 ms)
Maximum interrupting rating (inductive load)42 W (N/O contact, 24 V DC, τ = 40 ms)
42 W (N/O contact, 48 V DC, τ = 40 ms)
42 W (N/O contact, 60 V DC, τ = 40 ms)
42 W (N/O contact, 110 V DC, τ = 40 ms)
42 W (N/O contact, 220 V DC, τ = 40 ms)
Switching capacitymin. 50 mW
Mechanical service life10x 106 cycles
Switching capacity (360/h cycles)4 A (24 V (DC13))
4 A (250 V (AC15))
Switching capacity according to IEC 60947-5-13 A (24 V (DC13))
3 A (250 V (AC15))
Output fuse10 A gL/gG (N/O contact)
4 A gL/gG (N/O contact, for low-demand applications)
6 A gL/gG (N/C contact)

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight135.88 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Degree of protectionIP20
IP54
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow

Connection data

Connection methodSpring-cage connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)1
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)1
DesignationEN ISO 13849
Performance level (PL)c
Category1
Safety Integrity Level Claim Limit (SIL CL)1

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage250 V
250 V
Rated surge voltage/insulation4 kV basic insulation (4 kV safe isolation, reinforced insulation between A1/A2, 13/14, 23/24, 33/34 to 43/44, 53/54, 61/62, 71/72)
Degree of pollution2
Overvoltage categoryIII
Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.)
Vibration (operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
ConformanceCE-compliant

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.