PLC-OPT-230UC/230AC/1 2900374 PHOENIX CONTACT PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal bloc.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OPT-230UC/230AC/1 2900374 PHOENIX CONTACT PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal bloc..

PLC-OPT-230UC/230AC/1

2900374

PHOENIX_CONTACT

10

Available

Ship on today

PLC-INTERFACE, consisting of PLC-BPT.../21 basic terminal block with push-in connection and plug-in miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input: 230 V AC/220 V DC, output: 24 - 253 V AC/0.75 A

More details


Converters

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+23,50 €
20+22,96 €
30+22,69 €
40+22,67 €
*This price is per unit and is the net value (not including taxes if applicable).

Related products

More info



Dimensions

Width6.2 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C

Input data

Nominal input voltage UN230 V AC (220 V DC)
220 V DC
Input voltage range in reference to UN0.8 ... 1.1
Switching threshold "0" signal in reference to UN≤ 0.25
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN3.5 mA
Typical response time10 ms (at UN)
Typical turn-off time10 ms (at UN)
Operating voltage displayYellow LED
Type of protectionBridge rectifier
Protective circuit/componentBridge rectifier
Transmission frequency3 Hz

Output data

Output voltage range24 V AC ... 253 V AC
Limiting continuous current0.75 A (see derating curve)
Maximum inrush current30 A (10 ms)
Min. load current10 mA
Leakage current< 1 mA (in off state)
Max. load value4.5 A2s
Voltage drop at max. limiting continuous current< 1 V
Output circuit2-wire, floating
Type of protectionRCV circuit

Connection data, input side

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kV (50 Hz, 1 min.)
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title: Language: Size: Type:
PHOENIX CONTACT-2900374-PLC-OPT-230UC/230AC/1 English 125 Kbytes PHOENIX CONTACT-2900374-PLC-OPT-230UC/230AC/1

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review