Product successfully added to your shopping cart
MINI MCR-SL-2CP-I-I-SP
2864781
PHOENIX_CONTACT
1
Loop-powered isolators
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2864781 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 101 (C-7-2015) |
GTIN | 4017918974961 |
Weight per Piece (excluding packing) | 65.400 g |
Custom tariff number | 85437090 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -20 °C ... 65 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Description of the input | Current input |
---|---|
Number of inputs | 2 |
Configurable/programmable | no |
Current input signal | 0 mA ... 20 mA |
4 mA ... 20 mA | |
max. input voltage | 18 V |
Max. input current | 40 mA |
Response current | approx. 190 µA |
Input voltage limitation | < 2 V (20 mA) |
Voltage dissipation | 1.9 V (I = 20 mA) |
Output name | Current output |
---|---|
Number of outputs | 2 |
Configurable/programmable | no |
Current output signal | 0 mA ... 20 mA |
4 mA ... 20 mA | |
Load/output load current output | < 600 Ω (at I = 20 mA output signal) |
Ripple | < 10 mVrms(at 600 Ω) |
Transmission Behavior | 1:1 to input signal |
Supply voltage range | no separate supply voltage necessary |
---|---|
Power consumption | 34 mW (per channel) |
Connection method | Spring-cage connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Stripping length | 8 mm |
No. of channels | 2 |
---|---|
Maximum transmission error | ≤ 0.1 % (of final value) |
Maximum temperature coefficient | ≤ 0.002 %/K (of measured value / 100 Ω load) |
Temperature coefficient, typical | < 0.002 %/K (of measured value / 100 Ω load) |
Additional error, load-dependent | < 0.03 % (of measured value / 100 Ω load) |
Limit frequency (3 dB) | 75 Hz |
Step response (10-90%) | 5 ms (at 600 Ω load) |
Electrical isolation | Basic insulation according to EN 61010 |
Overvoltage category | II |
Degree of pollution | 2 |
Rated insulation voltage | 50 V AC/DC |
Test voltage input/output | 1.5 kV (50 Hz, 1 min.) |
Test voltage channel/channel | 1.5 kV (50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Color | green |
Housing material | PBT |
Mounting position | any |
Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA II T6 X |
UL, USA/Canada | UL 508 Recognized |
Class I, Div. 2, Groups A, B, C, D | |
GL | GL EMC 2 D |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
Designation | Electromagnetic RF field |
---|---|
Standards/regulations | EN 61000-4-3 |
Evaluation criterion | A |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Evaluation criterion | B |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Evaluation criterion | A |
Electromagnetic compatibility | Conformance with EMC directive |
---|---|
Noise emission | EN 61000-6-4 |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
Evaluation criterion | A |
Standards/regulations | EN 61000-4-4 |
EN 61000-4-5 | |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Evaluation criterion | A |
Electrical isolation | Basic insulation according to EN 61010 |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA II T6 X |
UL, USA/Canada | UL 508 Recognized |
Class I, Div. 2, Groups A, B, C, D | |
GL | GL EMC 2 D |
Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2864781-MINI MCR-SL-2CP-I-I-SP | 141 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.