IB IL AO 2/UI-XC-PAC 2701389 PHOENIX CONTACT Inline terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL AO 2/UI-XC-PAC 2701389 PHOENIX CONTACT Inline terminal

IB IL AO 2/UI-XC-PAC

2701389

PHOENIX_CONTACT

Inline terminal

Inline, Analog output terminal, Analog outputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, -20 mA... 20 mA, connection technology: 2 conductors, transmission rate on the local bus: 500 kBit/s, Extreme Conditions variant, protection rating: IP20, including inline connector and marking surface

Inline, Analog output terminal, Analog outputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline connector and labeling field

More details


PLC's > Fieldbus, decentr. periphery - analogue I/O module

I/O

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Technical data

Dimensions
Dimensional drawingpzuxqdohxi.jpg
Width12.2 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Inline local bus
Number of interfaces2
Connection methodInline data jumper
Transmission speed500 kbps
Transmission physicsCopper

System properties
Module
ID code (dec.)91
ID code (hex)5B
Length code (hex)04
Length code (dec)04
Process data channel64 bit
Input address area8 Byte
Output address area8 Byte
Register length64 bit
Required parameter data10 Byte
Required configuration data5 Byte

Output data
Analog:
Output nameAnalog outputs
Connection technology2-conductor
Note regarding the connection technologyshielded
Number of outputs2
D/A conversion timetyp. 10 µs
D/A converter resolution12 bit
Protective circuitShort-circuit and overload protection; Electronic
Transient protection; Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values12 bits (11 bits + sign bit)
Process data updatebus-synchronous
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current output≤ 450 Ω
Voltage output signal0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output> 1 kΩ
Permissible cable lengthmax. 250 m (The specifications refer to nominal operation after complying with installation instructions. The specifications refer to the following reference cable type: Shielded power station cable: LiYCY; 2 x 2 x 0,5 mm²; VDE0812)

Product properties
Product typeI/O component
Product familyInline
Typemodular
Scope of deliveryincluding Inline connector and labeling field
Special propertiesExtreme conditions version
Diagnostics messagesFailure of the internal I/O supply I/O error message sent to the bus coupler
I/O supply failure Message in the diagnostic code (in the IB IL format)
Short circuit/overload of the outputs Message in the diagnostic code (in the IB IL format)
Configuration invalid Message in the diagnostic code (in the IB IL format)
Data management status
Article revision03
Insulation characteristics
Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties
Potentials: Communications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current drawmax. 65 mA
typ. 55 mA
Potentials: Supply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 75 mA (Nominal current load (IOUT1/2= 20 mA, RL= 0 Ω))
max. 30 mA (No-load)
typ. 38 mA (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ))
max. 45 mA (Nominal voltage load (UOUT1/2= 10 V, RL= 1 kΩ))
typ. 65 mA (Nominal current load (IOUT1/2= 20 mA, RL= 0 Ω))
typ. 24 mA (No-load)
Electrical isolation/isolation of the voltage ranges
Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V analog supply (analog I/O)/functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameInline connector
Conductor connection
Connection methodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm
Inline connector
Connection methodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting
Mounting typeDIN rail mounting

ETIM for 2701389 PLC's (EC001596)
Feature Name Feature Value
Supply voltage DC (EF007534) 19.2 V
Voltage type (supply voltage) (EF002991) DC
Input, current (EF003204) No
Input, voltage (EF003205) No
Input, resistor (EF003206) No
Input, resistance thermometer (EF003207) No
Input, thermocouple (EF003208) No
Input signal, configurable (EF003209) No
Output, current (EF003212) Yes
Output, voltage (EF003213) Yes
Output signal configurable (EF003214) Yes
Resolution of the analogue outputs (EF003577) 12 Bit
Number of analogue inputs (EF001994) 0
Number of analogue outputs (EF001995) 2
Analogue inputs configurable (EF008518) No
Analogue outputs configurable (EF008519) Yes
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) Yes
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 12.15 mm
Height (EF000040) 120.110773 mm
Depth (EF000049) 70.430346 mm

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.