Product successfully added to your shopping cart
ILB BT ADIO MUX
2702875
PHOENIX_CONTACT
1
Wireless set
Wireless MUX game, two modules with 16 digital inputs and outputs each and 2 analog inputs and outputs (0 ... 20 mA, 0 ... 10 V), RSMA antenna connection (female), no antennas
PLC's > Fieldbus, decentr. periphery - analogue/digital I/O module
Safety
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Orderkey | 2702875 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 467 (C-6-2017) |
| GTIN | 4055626369846 |
| Weight per Piece (excluding packing) | 630.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 95 % |
| Air pressure (operation) | 795 hPa ... 1080 hPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Degree of protection | IP20 |
| Wireless standard | Based on Bluetooth 4.0 |
|---|---|
| Modulation type | GFSK (Gaussian Frequency Shift Keying) |
| Antenna connection method | RSMA (female) |
| Frequency range | 2.402 GHz ... 2.48 GHz (ISM bandwidth) |
| Transmission power | 5 dBm |
| Receiver sensitivity | -95 dBm |
| Connection method | Inline connector |
|---|---|
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30.5 V DC (via power connector) |
| Current consumption | 60 mA (at 24 V DC, at 25 °C) |
| Type of protection | Polarity protection, surge protection |
| Input name | Digital inputs |
|---|---|
| Connection method | Spring-cage connection |
| Connection technology | 1-wire |
| Number of inputs | 16 |
| 16 | |
| Input voltage range "0" signal | < 5 V |
| Input voltage range "1" signal | > 15 V |
| Typical input current per channel | 2.3 mA |
| Output name | Digital outputs |
|---|---|
| Connection method | Spring-cage connection |
| Connection technology | 1-wire |
| Number of outputs | 16 |
| Type of protection | Short-circuit protection, overload protection, protected against reverse voltages |
| Nominal output voltage | 24 V DC |
| Output current | 8 A |
| Maximum output current per channel | 500 mA |
| Nominal load, inductive | 12 VA (1.2 H, 50 Ω) |
| Nominal load, lamp | 12 W |
| Nominal load, ohmic | 12 W (48 Ω) |
| Description of the input | Single ended |
|---|---|
| Input name | Analog inputs |
| Number of inputs | 2 |
| Type of protection | Surge voltage |
| Measured value resolution | 12 bits |
| Current input signal | 0 mA ... 20 mA |
| Input resistance current input | 50 Ω |
| Voltage input signal | 0 V ... 10 V |
| Input resistance of voltage input | 130 kΩ |
| Number of outputs | 2 |
|---|---|
| Output name | Analog outputs |
| DAC resolution | 12 Bit |
| Current output signal | 0 mA ... 20 mA |
| Load/output load current output | ≤ 500 Ω |
| Voltage output signal | 0 V ... 10 V |
| Load/output load voltage output | ≥ 2 kΩ |
| Housing material | PA 6.6-FR |
|---|---|
| Mounting type | DIN rail |
| Net weight | 630 g |
| Note on weight specifications | one module, incl. connector, without antenna |
| Degree of pollution | 2 |
| MTTF | 1458 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 557 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| 219 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Diagnostics messages | Short-circuit / overload of the digital outputs LED |
| Wireless connection FS LED | |
| Logic and actuator voltage LED | |
| Link quality of the wireless connection 4 LEDs | |
| Delay time | ≤ 10 ms (Latency, typical) |
| ≤ 800 ms (Failsafe function for wireless interruption) | |
| Wireless licenses | Europe, additional countries in the e-shop |
| Wireless licences | Belgium |
| Bulgaria | |
| Denmark | |
| Germany | |
| Estonia | |
| Finland | |
| France | |
| Greece | |
| Great Britain | |
| Ireland | |
| Iceland | |
| Israel | |
| Italy | |
| Japan | |
| Canada | |
| Latvia | |
| Liechtenstein | |
| Lithuania | |
| Luxembourg | |
| Malta | |
| Netherlands | |
| Norway | |
| Austria | |
| Poland | |
| Portugal | |
| Romania | |
| Sweden | |
| Switzerland | |
| Singapore | |
| Slovakia | |
| Slovenia | |
| Spain | |
| South Africa | |
| Czech Republic | |
| Turkey | |
| Hungary | |
| USA | |
| Cyprus (rep.) | |
| Mounting type | DIN rail mounting |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Standard designation | RED directive 2014/53/EU |
| Standards/regulations | EN 300328 |
| EN 61000-6-4 | |
| EN 61000-6-2 | |
| EN 62311 | |
| EN 60950 | |
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 25g, 11 ms period, half-sine shock pulse | |
| Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 26 MHz ... 3 GHz (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Signal | ± 1 kV (Signal line, asymmetrical) |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz ... 80 MHz |
| Conformance | CE-compliant |
| FCC Directive, Part 15.247 | |
| ISC Directive RSS 210 | |
| UL, USA/Canada | UL 508 Listed |
| Protection class | III |
| MIC rating | Japan MIC (RF) ID:202-LSF002 |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Number of analogue inputs (EF001994) | 2 |
| Number of analogue outputs (EF001995) | 2 |
| Analogue inputs configurable (EF008518) | No |
| Analogue outputs configurable (EF008519) | No |
| Number of digital inputs (EF001992) | 16 |
| Number of digital outputs (EF001993) | 16 |
| Digital inputs configurable (EF008516) | No |
| Digital outputs configurable (EF008520) | No |
| Input current at signal 1 (EF001428) | 0 mA |
| Type of voltage (input voltage) (EF003033) | DC |
| Type of digital output (EF003601) | Other |
| Output current at digital output (EF003218) | 0.5 A |
| Output voltage at digital output (EF003215) | 24 V |
| Short-circuit protection, digital outputs available (EF003320) | Yes |
| Analogue input, current (EF003219) | Yes |
| Analogue input, voltage (EF003221) | Yes |
| Analogue input, resistor (EF003222) | No |
| Analogue input, resistor temperature (EF003224) | No |
| Analogue input, thermocouple (EF003225) | No |
| Analogue input signal configurable (EF003227) | No |
| Analogue output, current (EF003234) | Yes |
| Analogue output, voltage (EF003235) | Yes |
| Analogue output signal configurable (EF003236) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Type of electric connection (EF003961) | Other |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE AUTOMATION PHOENIX EN.pdf | 35 Mbytes |
|
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.