ANUNCIAR
MINI MCR-2-NAM-2RO 2902004 PHOENIX CONTACT Isolation amplifier View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI MCR-2-NAM-2RO 2902004 PHOENIX CONTACT Isolation amplifier

MINI MCR-2-NAM-2RO

2902004

PHOENIX_CONTACT

Isolation amplifier

Configurable NAMUR separation amplifier with plug-in connection technology for proximity initiators, potential-free contacts and resistively connected switching contacts. 2 transistor outputs, configurable via the DIP switch. Screw connection technology.

More details


Sensors > NAMUR switching amplifier

INTERFACE Components (IF)

Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total: $257.39
Unit price: $257.39
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Best sellers

More info



Key Commercial Data

Orderkey2902004
Packing unit1 pc
NoteMade to Order (non-returnable)
Catalog pagePage 90 (C-5-2017)
GTIN4046356651851
Weight per Piece (excluding packing)106.200 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width6.2 mm
Height110.5 mm
Depth120.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Power supply

Nominal supply voltage24 V DC
Supply voltage range9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption18 mA (24 V DC)
35 mA (12 V DC)
Power consumption450 mW (9.6 V DC)

Connection data

Connection methodScrew connection
Single conductor/terminal point, solid, with ferrule, min.0.20 mm²
Single conductor/terminal point, solid, with ferrule, max.1.50 mm²
Single conductor/terminal point, solid, without ferrule, min.0.20 mm²
Single conductor/terminal point, solid, without ferrule, max.2.50 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible12
Stripping length10 mm
Screw threadM3

General

No. of channels1
Status displayYellow LED (switching output)
Yellow LED (switching output)
Electrical isolationReinforced insulation in accordance with IEC 61010-1
Overvoltage categoryII
Degree of pollution2
Rated insulation voltage300 V (effective)
Test voltage, input/output/supply3 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgray
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Certificate of classificationDNV GL TAA000021E
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Standards/regulationsEN 61000-4-2
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
EN 61000-4-5
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Electrical isolationReinforced insulation in accordance with IEC 61010-1
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCA
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2902004 Sensors (EC001485)
Feature Name Feature Value
Type of power supply (EF001469) Other
Rated supply voltage DC (EF007078) 9.6 V
Number of inputs according to NAMUR (EF006886) 1
Number of inputs, potential-free (EF006887) 1
Switching voltage (EF003586) 30 V
Number of channels (EF000259) 1
Number of output circuits relays normally open contact (EF006992) 2
Number of output circuits relays change-over contact (EF006993) 0
Number of output circuits transistor potential-free (EF006997) 2
Number of output circuits transistor pnp (EF006996) 2
Number of output circuits transistor npn (EF006995) 0
Number of output circuits transistor antivalent (EF006994) 0
Number of output circuits opto-coupler (EF006991) 0
Malfunction message output (EF007499) No
Inherently safe according to EN 60947-5-6 NAMUR (EF007112) No
Galvanic separation between inputs (EF007224) No
Galvanic separation between input and output (EF007223) Yes
Galvanic separation between output to output (EF007222) Yes
Galvanic separation between supply voltage and all other current circuits (EF007225) Yes
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Width (EF000008) 6.2 mm
Height (EF000040) 109.81 mm
Power consumption (EF000346) 0.45 W
Operating temperature (EF002393) -40 °C
Construction type of device (EF007276) Built-in device
Type of electric connection (EF003961) Screw connection
Mounting method (EF000003) Other
Depth (EF000049) 119.2 mm
Degree of protection (IP) (EF005474) IP20

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.