MINI MCR-2-UI-UI 2902037 PHOENIX CONTACT 3-way signal conditioner with plug-in connection technology and cal.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI MCR-2-UI-UI 2902037 PHOENIX CONTACT 3-way signal conditioner with plug-in connection technology and cal..

MINI MCR-2-UI-UI

2902037

PHOENIX_CONTACT

3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover for the electrical isolation of unipolar and bipolar analog signals. Input/output configurable via DIP switch. Screw connection technology, standard configuration.

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $273.21
Unit price: $273.21

Quantity Price
1+$273.21
2+$252.44
3+$252.44
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Product description

The 3-way signal conditioner with plug-in connection technology and calibrated measuring range changeover can be configured using DIP switches and is used for the electrical isolation, conversion, amplification, and filtering of unipolar and bipolar standard and normalized signals. On the input side, the standard analog signals 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, 0 ... 5 V, 1 ... 5 V or -10 ... 10 V, and signals2 ... 10 V, 0 ... 20 V, 4 ... 20 V, 0 ... 24 V, 0 ... 30 V, -5 ... 5 V, -20 ... 20 V, -24 ... 24 V, -30 ... 30 V and -20 ... 20 mA are available. On the output side, 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, 0 ... 5 V, 1 ... 5 V, -10 ... 10 V and -5 ... 5 V are possible. There is no need for adjustment following a measuring range changeover. The measuring transducer supports fault monitoring and NFC communication.

Dimensions

Width6.2 mm
Height110.5 mm
Depth120.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Number of inputs1
Configurable/programmableYes
Voltage input signal0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
-5 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
-10 V ... 10 V (via DIP switch)
0 V ... 20 V (via DIP switch)
4 V ... 20 V (via DIP switch)
-20 V ... 20 V (via DIP switch)
0 V ... 24 V (via DIP switch)
4.8 V ... 24 V (via DIP switch)
-24 V ... 24 V (via DIP switch)
0 V ... 30 V (via DIP switch)
6 V ... 30 V (via DIP switch)
-30 V ... 30 V (via DIP switch)
Current input signal0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
-20 mA ... 20 mA (via DIP switch)
Max. input voltage33 V
Max. input current24 mA
Input resistance of voltage input> 1000 kΩ
Input resistance current inputapprox. 63 Ω

Output data

Number of outputs1
Configurable/programmableYes
Voltage output signal0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
-5 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
2 V ... 10 V (via DIP switch)
-10 V ... 10 V (via DIP switch)
Current output signal0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
Max. output current22 mA
Short-circuit current< 32 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output≤ 600 Ω (at 20 mA)

Power supply

Nominal supply voltage24 V DC
Supply voltage range9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Typical current consumption25 mA (Current output, at 24 V DC incl. load)
54 mA (Current output, at 12 V DC incl. load)
Power consumption≤ 800 mW (at IOUT= 20 mA, 9.6 V DC, 600 Ω load)

Connection data

Connection methodScrew connection
Single conductor/terminal point, solid, with ferrule, min.0.2 mm²
Single conductor/terminal point, solid, with ferrule, max.1.5 mm²
Single conductor/terminal point, solid, without ferrule, min.0.2 mm²
Single conductor/terminal point, solid, without ferrule, max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible12
Stripping length10 mm
Screw threadM3

General

No. of channels1
Maximum transmission error≤ 0.1 % (of final value)
≤ 0.15 % (of final value, at IN: 4 ... 20 mA / OUT: -10 V ... 10 V)
Maximum temperature coefficient0.01 %/K
Limit frequency (3 dB)30 Hz (via DIP switch)
5 kHz (via DIP switch)
Step response (10-90%)< 8.5 ms (with 30 Hz filter)
Protective circuitTransient protection
Electrical isolationReinforced insulation in accordance with IEC 61010-1
Overvoltage categoryII
Pollution degree2
Rated insulation voltage300 V (effective)
Test voltage, input/output/supply3 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgray
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEXEx II 3 G Ex nA IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Certificate of classificationDNV GL 14445-15HH

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
DesignationConducted interferences
Standards/regulationsEN 61000-4-6

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.