ELR H3-ES-SC-230AC/500AC-2
2900553
PHOENIX_CONTACT
1
2 in 1 hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, and emergency stop function.
Hybrid start controller for starting motors from 3~ AC up to 550 V AC, with 230 V AC input, 2.4 A output current and emergency stop function.
Home > PHOENIX CONTACT
Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Product Type | Hybrid Motor Starter |
| Product Family | CONTACTRON |
| Operating Mode | Working time 100% |
| Insulation Properties: Leak Lines and Air Gaps Between Circuits | |
| Isolation | Safe separation |
| Number of phases | 3 |
| Electrical service life | 3x 107operations |
| Investment frequency | ≤ 2 Hz |
| Maximum dissipation | 4.7 W |
| Minimal dissipated power | 2.6 W |
| Rating Type | 1 |
| Creepage lines and air gaps between circuits | |
| Sizing Insulation Voltage | 500 V |
| Dimensioning Transient Voltage | 6 kV |
| Feeding | |
| Assigned supply voltage of the control circuit Us | 230 V AC |
| Supply voltage range of the control system | 92 V AC ... 253 V AC |
| Sizing Control Power Current Is | 4 mA |
| Mains Frequency | 50/60 Hz |
| Protection Circuit | Prot. Surge |
| Control | |
| U-dimensioning drive voltageC | 230 V AC |
| Drive voltage range | 92 V AC ... 253 V AC |
| Mains Frequency | 50 Hz 60 Hz 50/60 Hz |
| Switching threshold | 44 V AC (signal "0") |
| 85 V AC (signal "1") | |
| Switching Level | < 5 V AC (for emergency stop) |
| Typical Shutdown Time | < 70 ms |
| AC Output | |
| Assigned operating voltage Uand | 500 V AC |
| Service voltage range | 42 V AC ... 550 V AC |
| Sizing Service Current Iand | 2.4 A (AC-51) |
| 2.4 A (AC-53a) | |
| Mains Frequency | 50/60 Hz |
| Charging Current Range | 180 mA ... 2.4 A (see derating) |
| Activation characteristic line according to IEC 60947-4-2 | Class 10A |
| Cool-down time | 20 min. (For automatic reset) |
| Leakage Current | 0 mA |
| Residual Stress | < 0.3 V |
| Protection Circuit | Prot. Surge |
| Feedback output | |
| Observation | Feedback 01: Switching contact without potential |
| Control circuit | |
| Connection type | Screw connection |
| Length to be de-insulated | 8 mm |
| Screw thread | M3 |
| Rigid conductor section | 0.2 mm² ... 2.5 mm² |
| Flexible conductor section | 0.2 mm² ... 2.5 mm² |
| AWG Conductor Section | 24 ... 14 |
| Charging circuit | |
| Connection type | Screw connection |
| Length to be de-insulated | 8 mm |
| Screw thread | M3 |
| Rigid conductor section | 0.2 mm² ... 2.5 mm² |
| Flexible conductor section | 0.2 mm² ... 2.5 mm² |
| AWG Conductor Section | 24 ... 14 |
| Status Indication | LED (yellow) |
| Operating voltage display | Green LED |
| Error Indication | Red LED |
| Width | 22.5 mm |
| Height | 107 mm |
| Depth | 114 mm |
| Flammability class according to UL 94 | V0 (Housing) |
| Environmental conditions | |
| Protection Index | IP20 |
| Ambient Temperature (Service) | -25°C ... 70 °C |
| Ambient Temperature (Storage/Transport) | -40 °C ... 80 °C |
| Safety Integrity Level (SIL, IEC 61508) | |
| Marked | ≤ 3 |
| Observation | Safe Disconnect |
| Performance Level (ISO 13849) | |
| Marked | and |
| Observation | Safe Disconnect |
| Category (ISO 13849) | |
| Marked | ≤ 3 |
| Observation | Safe Disconnect |
| UL Data | |
| SCCR | 100 kA (480 V AC (30 A Class DC / 30 A Class J (High-Fault)) fuse) |
| 5 kA (480 V AC (20 A RK5 (Standard-Fault))) | |
| FLA | 2.4 A (480 V) |
| Standards / Specifications | |
| Standards/Specifications | DIN EN 50178 |
| EN 60947 | |
| Requirements for power plants | |
| Standards/Specifications | DWR 1300/ZXX01/DD/7080.8d |
| Creepage lines and air gaps between circuits | |
| Standards/Specifications | DIN EN 50178 |
| Installation instructions | Alignment with spacing = 20 mm |
| Position for mounting | Vertical (horizontal rail) |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.