Product successfully added to your shopping cart
ELR H3-IES-SC-230AC/500AC-2
2900568
PHOENIX_CONTACT
1
3 in 1 hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function, and adjustable overload shutdown.
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Width | 22.5 mm |
---|---|
Height | 99 mm |
Depth | 114.5 mm |
Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Degree of protection | IP20 |
Rated control circuit supply voltage US | 230 V AC (50/60 Hz) |
---|---|
Control supply voltage range | 85 V AC ... 253 V AC |
Rated control supply current IS | 4 mA |
Protective circuit | Surge protection |
Input name | Control input right/left |
---|---|
Rated actuating voltage UC | 230 V AC |
Voltage range | 85 V AC ... 253 V AC |
Rated actuating current IC | 7 mA |
Switching threshold | 44 V AC (“0” signal) |
85 V AC (“1” signal) | |
Switching level | < 5 V AC (For EMERGENCY STOP) |
Typical turn-off time | < 70 ms |
Output name | AC output |
---|---|
Rated operating voltage Ue | 500 V AC |
Operating voltage range | 42 V AC ... 550 V AC |
Mains frequency | 50 Hz |
60 Hz | |
Load current range | 180 mA ... 2.4 A (see to derating) |
Trigger characteristic in acc. with IEC 60947 | Class 10A |
Cooling time | 20 min. (for auto reset) |
Rated operating current at AC-51 | 2.4 A |
Rated operating current at AC-53a | 2.4 A |
Leakage current | 0 mA |
Protective circuit | Surge protection |
Output name | Acknowledge output |
---|---|
Note | Confirmation: floating change-over contact, signal contact |
Contact type | 1 PDT |
Switching capacity according to IEC 60947-5-1 | 3 A (230 V, AC15) |
2 A (24 V, DC13) |
Switching frequency | ≤ 2 Hz (Load-dependent) |
---|---|
Mounting position | vertical (horizontal DIN rail, motor output below) |
Assembly instructions | alignable, for spacing see derating |
Operating mode | 100% operating factor |
Maximum power dissipation | 4.1 W |
Minimum power dissipation | 0.88 W |
Operating voltage display | Green LED |
Status display | Yellow LED |
Indication | Red LED |
Connection name | Control circuits |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Torque | 0.5 Nm ... 0.6 Nm |
Connection name | Load circuit |
---|---|
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 14 |
Torque | 0.5 Nm ... 0.6 Nm |
Designation | Standards/regulations |
---|---|
Standards/regulations | IEC 60947-1 |
EN 60947-4-2 | |
IEC 61508 | |
ISO 13849 |
Rated insulation voltage | 500 V |
---|---|
Rated surge voltage | 4 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Designation | Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
Insulation | Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC |
Safe isolation (EN 50178) at operating voltage ≤ 300 V AC | |
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC | |
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC | |
Designation | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
Insulation | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Safety Integrity Level according to IEC 61508 | SIL 3 (safe shutdown) |
---|---|
SIL 2 (motor protection) | |
Category acc. to EN ISO 13849 | 3 (Safe shutdown) |
Performance level according to ISO 13849 | e (Safe shutdown) |
ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] | |
EU-type examination certificate | PTB 07 ATEX 3145 |
SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
---|---|
5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) | |
FLA | 2.4 A (480 V AC) |
Group installation | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) | |
Category code | NLDX / NRNT |
Designation | Standards/regulations |
---|---|
Standards/regulations | IEC 60947-1 |
EN 60947-4-2 | |
IEC 61508 | |
ISO 13849 | |
ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
II (2) D [Ex t] [Ex p] |
eCl@ss 4.0 | 27371102 |
---|---|
eCl@ss 4.1 | 27371102 |
eCl@ss 5.0 | 27371601 |
eCl@ss 5.1 | 27371601 |
eCl@ss 6.0 | 27371601 |
eCl@ss 7.0 | 27371601 |
eCl@ss 8.0 | 27370905 |
eCl@ss 9.0 | 27370905 |
ETIM 2.0 | EC000066 |
---|---|
ETIM 3.0 | EC000066 |
ETIM 4.0 | EC000066 |
ETIM 5.0 | EC002055 |
UNSPSC 6.01 | 30211915 |
---|---|
UNSPSC 7.0901 | 39121514 |
UNSPSC 11 | 39121514 |
UNSPSC 12.01 | 39121514 |
UNSPSC 13.2 | 39121514 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2900568-ELR H3-IES-SC-230AC/500AC-2 | 150 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.