Orderkey | 2909903 |
---|---|
Packing unit | 1 pc |
GTIN | 4055626408712 |
Weight per Piece (excluding packing) | 27.580 g |
Custom tariff number | 85363010 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -25 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Humidity test | 96 h, 95 % RH, 40 °C |
Altitude | ≤ 2000 m (amsl (above mean sea level)) |
Shock (operation) | 30g (IEC 60068-2-27, Test Ea) |
Vibration (operation) | 10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc) |
59.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc) | |
Degree of protection | IP20 |
Flammability rating according to UL 94 | V-0 |
---|---|
Mounting type | DIN rail: 35 mm |
Color | traffic grey A RAL 7042 |
Number of positions | 1 |
Protection class | III |
Type | DIN rail module, one-piece |
Fuse type | electronic |
---|---|
Rated surge voltage | 0.5 kV |
Operating voltage | 18 V DC ... 30 V DC |
Rated voltage | 24 V DC |
Rated current IN | 24 A DC (Total current input) |
2 A DC (Rated current output) | |
Measuring tolerance I | ± 15 % |
Feedback resistance | max. 35 V DC |
Fail-safe element | 4 A DC |
Efficiency | > 99 % |
Closed circuit current I0 | typ. 12 mA |
Power dissipation | typ. 0.3 W (No-load operation) |
< 0.8 W (Nominal operation) | |
Module initialization time | 1 s |
Waiting time after switch off of a channel | 5 s (at overload / short circuit) |
Temperature derating | 21 A (Total current at 60°C) |
24 A (Total current at 50°C) | |
2 A (Channel current at 60°C) | |
2 A (Channel current at 50°C) | |
Tripping method | E (electronic) |
Required backup fuse | not required, integrated failsafe element |
Dielectric strength | max. 35 V DC (Load circuit) |
Voltage drop | 0.06 V (at 2 A) |
MTBF (IEC 61709, SN 29500) | 28571428 h (at 25°C with 21% load) |
14084507 h (at 40°C with 34.25% load) | |
2053388 h (at 60°C with 100% load) | |
Shutdown time load circuit | ≤ 10 ms (for short circuit > 2.0 x IN) |
1 s (1.2 ... 2.0 x IN) | |
Undervoltage shutdown load circuit | ≤ 17.8 V DC (active) |
≥ 18.8 V DC (inactive) | |
Surge voltage shutdown load circuit | ≥ 30.5 V DC (active) |
≤ 29.5 V DC (inactive) | |
Max. capacitive load load circuit | 20000 µF (Depending on the available short-circuit current) |
Connection name | Remote indication circuit |
---|---|
Switching function | N/O contact |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 14 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
DC operating voltage | 0 V DC ... 30 V DC |
DC operating current | 100 mA DC |
Channel LED off | off (Channel switched off) |
---|---|
Channel LED green | lit (Channel switched on) |
Channel LED yellow | lit (Channel switched on, channel load > 80% ) |
flashing (Programming mode active) | |
Channel LED red | lit (Channel switched off, over- or undervoltage active) |
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release) | |
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release) | |
flashing quickly (Channel switched off, external voltage at the output, possible installation error) |
Connection name | Main circuit IN+ |
---|---|
Connection method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
Connection name | Main circuit IN- |
Connection method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
Connection name | Main circuit OUT |
Connection method | Push-in connection |
Stripping length | 10 mm |
Conductor cross section solid | 0.2 mm² ... 4 mm² |
Conductor cross section AWG | 24 ... 12 |
Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.2 mm² ... 2.5 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
Standards/specifications | EN 61000-6-2 |
---|---|
EN 61000-6-3 | |
EN 60068-2-78 | |
EN 50178 | |
EN 60068-2-6 | |
EN 60068-2-27 | |
UL 508 | |
UL 2367 | |
UL 1310 Class 2 Power Units |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.