CBMC E4 24DC/1-10A NO 2906032 PHOENIX CONTACT Electronic device circuit breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CBMC E4 24DC/1-10A NO 2906032 PHOENIX CONTACT Electronic device circuit breaker

CBMC E4 24DC/1-10A NO

2906032

PHOENIX_CONTACT

Electronic device circuit breaker

More details


Over Current Protection

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $196.53
Unit price: $196.53

Quantity Price
1+$196.53
2+$167.03
3+$155.03
4+$151.26
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2906032
Packing unit1 pc
Catalog pagePage 316 (C-4-2017)
GTIN4055626149356
Weight per Piece (excluding packing)121.400 g
Custom tariff number85363090
Country of originDE (Germany)

Dimensions

Height90 mm
Width36 mm
Depth98 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Humidity test96 h, 95 % RH, 40 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Shock (operation)30g (IEC 60068-2-27, Test Ea)
Vibration (operation)10 Hz ... 57.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
57.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
Degree of protectionIP20

General

Flammability rating according to UL 94V-0
Mounting typeDIN rail: 35 mm
Colorlight grey RAL 7035
Number of positions4
Protection classIII
TypeDIN rail module, one-piece

Electrical data

Fuse typeelectronic
Rated surge voltage0.5 kV
Operating voltage18 V DC ... 30 V DC
Rated voltage24 V DC
Rated current INmax. 40 A DC (IN+)
max. 40 A DC (per terminal position when bridging additional devices via IN+)
Measuring tolerance I± 15 %
Feedback resistancemax. 35 V DC
Fail-safe element15 A DC (per output channel)
Efficiency> 99 %
Closed circuit current I0typ. 33 mA
Power dissipationtyp. 0.8 W (No-load operation)
< 9 W (Nominal operation)
Module initialization time1.6 s
Waiting time after switch off of a channel5 s (at overload / short circuit)
Temperature derating24 A DC (at 60 °C)
28 A DC (at 54°C)
32 A DC (at 47°C)
36 A DC (at 41 °C)
40 A DC (at 35 °C)
Tripping methodE (electronic)
Required backup fusenot required, integrated failsafe element
Dielectric strengthmax. 35 V DC (Load circuit)
MTBF (IEC 61709, SN 29500)8403361 h (at 25°C with 21% load)
3067484 h (at 40°C with 34.25% load)
534188 h (at 35°C with 100% load)
Shutdown time load circuit≤ 10 ms (for short circuit > 2.0 x IN)
1 s (1.2 ... 2.0 x IN)
Undervoltage shutdown load circuit≤ 17.8 V DC (active)
≥ 18.8 V DC (inactive)
Surge voltage shutdown load circuit≥ 30.5 V DC (active)
≤ 29.5 V DC (inactive)
Max. capacitive load load circuit45000 µF (Depending on the current setting and the short-circuit current available)

Remote indication contact

Connection nameRemote indication circuit
Switching functionN/O contact
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
DC operating voltage0 V DC ... 30 V DC
DC operating current100 mA DC

Signaling

Channel LED offoff (Channel switched off)
Channel LED greenlit (Channel switched on)
Channel LED yellowlit (Channel switched on, channel load > 80% )
flashing (Programming mode active)
Channel LED redlit (Channel switched off, over- or undervoltage active)
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
two flashes (Channel switched off, device total current limit 40 A exceeded)

Connection data

Connection nameMain circuit IN+
Connection methodPush-in connection
Stripping length15 mm
Conductor cross section solid0.2 mm² ... 10 mm²
Conductor cross section AWG24 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 6 mm²
Connection nameMain circuit IN-
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
Connection nameMain circuit OUT
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²

Standards and Regulations

Standards/specificationsEN 61000-6-2
EN 61000-6-3
EN 60068-2-6
EN 60068-2-27
EN 60068-2-78
EN 50178
UL 2367
UL 508

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications

Datasheet - PDF

Title: Size: Type:
PDF CATALOG PHOENIX PROTECTION EN.pdf 27 Mbytes

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.