Product successfully added to your shopping cart
MB 50-3+NPE
5096675
OBO BETTERMANN
1
Multibase MB50 3-pole + NPE,
CombiController V50 base. Base for V 50-B+C, combination arrester, lightning and surge arrester, type 1+2 • Suitable for V25-B+C, V20-C and V10-C• Pre-mounted and ready for connection• Multifunction terminals for easy connection with series-mounted devices• Upper parts can be rotated through 180 degrees• 3+1 protection circuit for TN-S and TT network systems Application: Lightning protection equipotential bonding in buildings, even those with external lightning protection of class III and IV, and in standard distributor housings.Base
Earthing, lightning and surge protection > Basic element for surge protection device
TBS Transient and lightning protection systems - OBO BETTERMANN > Surge protection, arrestor, type 1+2 (office and housing) - OBO BETTERMANN
Brand new product in its original packaging covered by the warranties and certifications provided by OBO BETTERMANN
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
| Arrester surge current (8/20 µs) [total] | 50 kA |
|---|---|
| Blow-out | no |
| CO2 Footprint (GWP) Cradle-to-Gate | 1,3266 kg CO2e / 1 Piece |
| Conductor cross-section, rigid (single-wire/multiwire), max. | 35 mm² |
| Conductor cross-section, rigid (single-wire/multiwire), min. | 2,5 mm² |
| DC network form | no |
| Dimension | 3+NPE |
| Installation type | DIN rail 35 mm |
| Integrated back-up fuse | no |
| IT network form | no |
| Lightning protection zone LPZ | 0→2 |
| Lightning surge current (10/350) | 50 kA |
| Max. mains-side overcurrent protection | 125 |
| Maximum back-up fuse | 125 A |
| Maximum continuous voltage (N-PE) | 255 V |
| Maximum continuous voltage AC | 280 V |
| Maximum discharge current (8/20 μs) | 50 kA |
| Network form | Other |
| Nominal discharge current (8/20 µs) [N-PE] | 50 kA |
| Nominal voltage AC (50/60 Hz) | 230 V |
| Operating temperature, max. | 80 °C |
|---|---|
| Operating temperature, min. | -40 °C |
| Other network form | no |
| Permitted temperature range, max. | 80 °C |
| Permitted temperature range, min. | -40 °C |
| Pole number | 3 |
| Pole version | 3+N/PE |
| Protection level [L-N] | ≤1,3 |
| Protection rating | IP20 |
| Remote signalling | no |
| Response time | <25 ns |
| Signalling on device | Visual |
| SPD to EN 61643-11 | Type 1+2 |
| SPD to IEC 61643-1 | Class I+II |
| TN network form | yes |
| TN-C network form | yes |
| TN-C-S network form | yes |
| TN-S network form | yes |
| TT network form | yes |
| Version for | 3+NPE base |
| Title: | Size: | Type: |
|---|---|---|
| PDF CATALOGUE SURGE PROTECTION OBO EN.pdf | 24 Mbytes |
|
| MB 50-3+NPE 5096675 OBO BETTERMANN Multibase MB50 3-pole + NPE, | 51 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.