T0-1-8295/XZ
009760
EATON-MOELLER
1
Changeover switch, 1p, Ie=12A, 45°, momentary, replacement switch, base fixing
Cam switch according to IEC/EN60947, size T0, without handle, snap screw-floor fastener, rated uninterrupted current Iu 20A, rated operating voltage Ue 690V, deliverable accessories according to catalog information cam switch T. General designs: insulation-material add-on housing, flush mounting, center mounting, rear mounting IVS service distribution board mounting.
Low-voltage industrial components > Control switch
Disconnectors and Cam Switches
Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product range | Control switches | ||
Part group reference | T0 | ||
Contacts | 2 | ||
Design | rear mounting Basic switch | ||
Contact sequence | |||
| General | |||
Standards | IEC/EN 60947, VDE 0660, IEC/EN 60204 Switch-disconnector according to IEC/EN 60947-3 | ||
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | ||
Ambient temperature | |||
Open | °C | -25 - +50 | |
Enclosed | °C | -25 - +40 | |
Overvoltage category/pollution degree | III/3 | ||
Rated impulse withstand voltage | Uimp | V AC | 6000 |
Mechanical shock resistance | g | 15 | |
Mounting position | As required | ||
Protection against direct contact when actuated from front (EN 50274) | Finger and back-of-hand proof | ||
| Contacts | |||
Electrical characteristics | |||
Rated operational voltage | Ue | V AC | 690 |
Rated uninterrupted current | Iu | A | 20 |
Note on rated uninterrupted current !u | Rated uninterrupted current Iu is specified for max. cross-section. | ||
Load rating with intermittent operation, class 12 | |||
AB 25 % DF | x Ie | 2 | |
AB 40 % DF | x Ie | 1.6 | |
AB 60 % DF | x Ie | 1.3 | |
Short-circuit rating | |||
Fuse | A gG/gL | 20 | |
Rated short-time withstand current (1 s current) | Icw | Arms | 320 |
Note on rated short-time withstand current lcw | Current for a time of 1 second | ||
Rated conditional short-circuit current | Iq | kA | 6 |
| Switching capacity | |||
cos ϕ rated making capacity as per IEC 60947-3 | A | 130 | |
Rated breaking capacity cos ϕ to IEC 60947-3 | A | ||
230 V | A | 100 | |
400/415 V | A | 110 | |
500 V | A | 80 | |
690 V | A | 60 | |
Safe isolation to EN 61140 | |||
between the contacts | V AC | 440 | |
Current heat loss per contact at Ie | W | 0.6 | |
Current heat loss per auxiliary circuit at Ie(AC-15/230 V) | CO | 0.6 | |
Lifespan, mechanical | Operations | x 106 | > 0.4 |
Maximum operating frequency | Operations/h | 1200 | |
AC | |||
AC-3 | |||
Rating, motor load switch | P | kW | |
220 V 230 V | P | kW | 3 |
230 V Star-delta | P | kW | 5.5 |
400 V 415 V | P | kW | 5.5 |
400 V Star-delta | P | kW | 7.5 |
500 V | P | kW | 5.5 |
500 V Star-delta | P | kW | 7.5 |
690 V | P | kW | 4 |
690 V Star-delta | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 11.5 |
230 V star-delta | Ie | A | 20 |
400V 415 V | Ie | A | 11.5 |
400 V star-delta | Ie | A | 20 |
500 V | Ie | A | 9 |
500 V star-delta | Ie | A | 15.6 |
690 V | Ie | A | 4.9 |
690 V star-delta | Ie | A | 8.5 |
AC-21A | |||
Rated operational current switch | |||
440 V | Ie | A | 20 |
AC-23A | |||
Motor rating AC-23A, 50 - 60 Hz | P | kW | |
230 V | P | kW | 3 |
400 V 415 V | P | kW | 5.5 |
500 V | P | kW | 7.5 |
690 V | P | kW | 5.5 |
Rated operational current motor load switch | |||
230 V | Ie | A | 13.3 |
400 V 415 V | Ie | A | 13.3 |
500 V | Ie | A | 13.3 |
690 V | Ie | A | 7.6 |
DC | |||
DC-1, Load-break switches L/R = 1 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 60 | |
DC-21A | Ie | A | |
Rated operational current | Ie | A | 1 |
Contacts | Quantity | 1 | |
DC-23A, motor load switchL/R = 15 ms | |||
24 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 1 | |
48 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 2 | |
60 V | |||
Rated operational current | Ie | A | 10 |
Contacts | Quantity | 3 | |
120 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 3 | |
240 V | |||
Rated operational current | Ie | A | 5 |
Contacts | Quantity | 5 | |
DC-13, Control switches L/R = 50 ms | |||
Rated operational current | Ie | A | 10 |
Voltage per contact pair in series | V | 32 | |
Control circuit reliability at 24 V DC, 10 mA | Fault probability | HF | < 10-5, < 1 fault in 100000 operations |
| Terminal capacities | |||
Solid or stranded | mm2 | 1 x (1 - 2,5) 2 x (1 - 2,5) | |
Flexible with ferrules to DIN 46228 | mm2 | 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) | |
Terminal screw | M3.5 | ||
Max. tightening torque | Nm | 1 | |
| Technical safety parameters: | |||
Notes | B10dvalues as per EN ISO 13849-1, table C1 | ||
| Low-voltage industrial components (EG000017) / Control switch (EC002611) | |||
| Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Control switch ([email protected] [ACN998008]) | |||
Type of switch | Reverser | ||
Number of poles | 1 | ||
Max. rated operation voltage Ue AC | V | 690 | |
Rated permanent current Iu | A | 20 | |
Number of switch positions | 2 | ||
With 0 (off) position | No | ||
With retraction in 0-position | No | ||
Device construction | Built-in device | ||
Width in number of modular spacings | 0 | ||
Suitable for ground mounting | Yes | ||
Suitable for front mounting 4-hole | No | ||
Suitable for distribution board installation | No | ||
Suitable for intermediate mounting | Yes | ||
Complete device in housing | No | ||
Type of control element | - | ||
Front shield size | 48x48 mm | ||
Degree of protection (IP), front side | IP00 | ||
| Feature Name | Feature Value |
|---|---|
| With zero (off) position (EF001416) | No |
| With retraction in 0-position (EF002428) | No |
| Suitable for floor mounting (EF007243) | No |
| Suitable for front mounting (EF007246) | No |
| Suitable for distribution board installation (EF007262) | No |
| Suitable for intermediate mounting (EF007264) | No |
| Complete device in housing (EF007317) | No |
| Title: | Size: | Type: |
|---|---|---|
| PDF EATON SAFE SWITCHING EN.pdf | 935 Kbytes |
|
| PDF CATALOGUE EATON EN .pdf | 38 Mbytes |
|
| T0-1-8295/XZ 009760 009760_EN.pdf | 211 Kbytes |
![]() |
No customer reviews for the moment.
| Rating: |
|
| Name: | |
| Email: | |
| Subject: | |
| Text: | |
| Do you recommend this product to buy? | |
|
|
|
| Add review | |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.