EASY-BOX-E4-AC1 197229 EATON ELECTRIC Starter package consisting of EASY-E4-AC-12RC1, patch cable and softwa.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EASY-BOX-E4-AC1 197229 EATON ELECTRIC Starter package consisting of EASY-E4-AC-12RC1, patch cable and softwa..

EASY-BOX-E4-AC1

197229

EATON-MOELLER

Starter package consisting of EASY-E4-AC-12RC1, patch cable and software license for easySoft

EASY-BOX-E4-AC1

Eaton Moeller® series EASY Starter package consisting of EASY-E4-AC-12RC1, patch cable and software license for easySoft

More details


PLC's > Logic module

Easy E4 Nanocontrollers

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $298.05
Unit price: $298.05

Quantity Price
1+$298.05
2+$263.80
3+$263.80
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series EASY Starter kit
Catalog Number
197229
Model Code
EASY-BOX-E4-AC1
EAN
4015080892908
Product Length/Depth
200 mm
Product Height
135 mm
Product Width
255 mm
Product Weight
0.6 kg
Compliances
Eaton supports the product until its end of life
Certifications
EN 55011
EN 55022
IEC/EN 61000-4
IEC/EN 61000-4-2
IEC 60068-2-6
IEC 60068-2-27
Catalog Notes
depending on ambient air temperature fluctuations of up to ± 5 s/day (± 0.5 h⁄year) are possible

Features & Functions

Fitted with:
Basic device
Connection cable
Control unit
Software preinstalled
Programming software

General

Insulation resistance
According to EN 50178
Mounting method
Screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage category
III
Pollution degree
2
Type
Starter kit

Ambient conditions, mechanical

Drop and topple
50 mm Drop height, Drop to IEC/EN 60068-2-31
Mounting position
Vertical
Horizontal
Shock resistance
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts

Climatic environmental conditions

Air pressure
795 - 1080 hPa (operation)
Environmental conditions
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 142
Condensation: prevent with appropriate measures
Relative humidity
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)

Electro magnetic compatibility

Air discharge
8 kV
Contact discharge
6 kV
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)

Design verification

10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Meets the product standard's requirements.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.