ANUNCIAR
DILM12-XSPD 101672 Y7-101672 EATON ELECTRIC Diode suppressor, for DILA, M7-15 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DILM12-XSPD 101672 Y7-101672 EATON ELECTRIC Diode suppressor, for DILA, M7-15

DILM12-XSPD

101672

Y7-101672

EATON-MOELLER

10

Diode suppressor, for DILA, M7-15

DILM12-XSPD

Eaton Moeller® series DILM Diode suppressor, for DILA, M7-15

Diode suppressor, Accessories: Suppressor circuit, Voltage: Us 12 - 250 DC V, For use with: DILM7 - DILM15, DILMP20, DILA

More details


Low-voltage industrial components > Surge protection module

Contactors up to 170A

Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total: $112.81
Unit price: $11.28
This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

Often bought together

Best sellers

More info



General specifications

Product Name
Eaton Moeller® series DILM diode suppressor
Catalog Number
101672
Model Code
DILM12-XSPD
EAN
4015081015641
Product Length/Depth
48 mm
Product Height
25 mm
Product Width
9 mm
Product Weight
0.004 kg
Certifications
UL Category Control No.: NKCR2, NKCR8
CSA File No.: 256465
UL Recognized
CSA-C22.2 No. 14-05
UL File No.: E29184
CSA
CSA Class No.: 3211-07
IEC/EN 60947-4-1
UL 508
CE

Features & Functions

Functions
Diode

General

Product category
Accessories
Used with
DILM12-XSPD
Voltage type
DC

Climatic environmental conditions

Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
60 °C

Magnet system

Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Rated control supply voltage (Us) at DC - min
12 V
Rated control supply voltage (Us) at DC - max
250 V

Design verification

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Rated operational current for specified heat dissipation (In)
0 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

ETIM for 101672 Low-voltage industrial controls and switchgear (EC000683)
Feature Name Feature Value
Function (EF000030) Diode
Voltage type (operating voltage) (EF005294) AC
Operating voltage AC 50 Hz (EF008206) 0 V
Operating voltage AC 60 Hz (EF008207) 0 V
Operating voltage DC (EF008208) 12 V
With LED indication (EF005950) No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.