NZM4-XAS14-1250 283291 EATON ELECTRIC Adapter set, 1250A, NZM4/NZM14 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-XAS14-1250 283291 EATON ELECTRIC Adapter set, 1250A, NZM4/NZM14

NZM4-XAS14-1250

283291

EATON-MOELLER

Available Ship on today

These delivery times are estimations and may vary when the item order has been processed. You will be notified of any change to delivery times once the order has been processed.

Adapter set, 1250A, NZM4/NZM14

More details


Low-voltage industrial components > Connection vane/phase spreader

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $644.43
Unit price: $644.43

Quantity Price
1+$644.43
2+$644.43
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Adapter set, 1250A, NZM4/NZM14
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch. 3 connection extensions on outlet side. 3 connection extensions on trip block side. 1 long shroud for the outlet side. paper drilling template in the assembly and maintenance instructions. Cannot be combined with module plate (NZM4-XKM..), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV..), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV..). Can be used for: NZM4, N4

Delivery program

Accessories
Connection adapter set
Number of conductors
3 pole
Rated current [In]
≦ 1250 A
For use with
NZM4, N4
Notes

Conversion kit for NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch.

3 connection extensions on outlet side

3 connection extensions on trip block side

1 long shroud for the outlet side

Paper drilling template in the assembly instructions (AWA)

Cannot be combined with the module plate (NZM4-XKM…), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV…), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV…).

Design verification as per IEC/EN 61439

IEC/EN 61439 design verification
10.2 Strength of materials and parts10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2 Strength of materials and parts10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9 Insulation properties10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9 Insulation properties10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9 Insulation properties10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 7.0

Low-voltage industrial components (EG000017) / Connection vane/phase spreader (EC002019)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Component for low-voltage switching technology / Connection vane/phase spreader ([email protected] [ACN990012])
Suitable for number of poles
3

Dimensions

123X554

Datasheet - PDF

Title: Size: Type:
NZM4-XAS14-1250 283291 EN_283291.pdf 199 Kbytes   NZM4-XAS14-1250  283291 EN_283291.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.