Current monitoring relays are essential protective devices designed to continuously measure electrical current in a circuit and trigger an output when the current exceeds or falls below preset thresholds. These relays, often referred to as overcurrent relays or undercurrent relays, are available in various configurations including single-phase a...

Current monitoring relays are essential protective devices designed to continuously measure electrical current in a circuit and trigger an output when the current exceeds or falls below preset thresholds. These relays, often referred to as overcurrent relays or undercurrent relays, are available in various configurations including single-phase and three-phase models. Key technical parameters include adjustable current ranges (e.g., 0.1-10A or 1-100A), time delay settings for trip curves, and supply voltages such as 24V DC, 110V AC, or 230V AC. They typically feature SPDT or DPDT output contacts rated for switching loads up to 5A or 8A at 250V AC. Many models offer selectable trip characteristics like definite time or inverse time, and some include LED indicators for status monitoring. The mounting options include DIN rail or panel mount, with enclosure ratings from IP20 to IP40 for industrial environments.

Current monitoring relays are widely deployed in industrial automation, motor control centers, and power distribution systems. Common applications include protecting motors from overload or phase loss, monitoring pump and fan loads for dry-run or jam conditions, and supervising heating elements or lighting circuits for fault detection. They are also used in HVAC systems to monitor compressor current, in conveyor systems to detect belt slip or blockage, and in generator sets for load sharing and protection. These relays integrate seamlessly into PLC and SCADA systems via their output contacts, enabling remote alarm or shutdown functions. They are particularly valuable in continuous process industries such as water treatment, food processing, and manufacturing, where equipment protection and uptime are critical.

Within the category of current monitoring relays, key subcategories include overcurrent relays, undercurrent relays, and combined over/undercurrent relays. Popular article codes often follow a structured format, such as "CMR-1A-230V" for a single-phase relay with 1A range and 230V supply, or "CMR-3P-10A-24V" for a three-phase model. Other common codes include "OCR-100A-AC" for overcurrent relays and "UCR-5A-DC" for undercurrent types. These codes typically incorporate the relay type, current range, supply voltage, and number of phases. Specific models may include the Allen-Bradley 193-ECM series, Siemens 3UG4 series, or Schneider Electric RM22 series, each offering distinct features like adjustable hysteresis or remote reset capabilities.

Partnering with Electric Automation Network for your current monitoring relay needs ensures access to a vast inventory of genuine products from leading manufacturers, all with real-time pricing and availability. Our team of specialized electrical engineers provides personalized technical support to help you select the correct relay for your application, whether it involves specific current ranges, time delays, or environmental conditions. We offer express worldwide shipping to minimize downtime, and each product includes detailed technical documentation, datasheets, and wiring diagrams. Benefit from our multilingual web portal and dedicated account management to streamline your procurement process and ensure compliance with international standards.

More
Number of products per page:
Order:
Manufacturer Code Reference Catalog Number Description Delivery Price

5TT6113

5TT6113

-

undercurrent relay T5570 230V AC 1/5/10/15A 1-phase with transparent cap

Current relay >N<, to monitor infracurrents, 2 modules, 230 V AC, 5 A, 4 measurement areas (from 0.1 to 15 A, 1 phase, 2 switches. Manufactured to customer specifications. Non-Cancelable Non-Returnable.

3 View Availability View Price

5TT6114

5TT6114

-

overcurrent relay T5570 230V AC 1/5/10/15A 1-phase with transparent cap

Current relay >N<, to monitor overcurrents, 2 modules, 230 V AC, 5 A, 4 measurement areas (from 0.1 to 15 A), 1 phase, 2 switches. Cancelations and returns limited. Consult conditions.

3 View Availability View Price

5TT6112

5TT6112

-

overcurrent relay T5570 230V AC 10A 1-phase with transparent cap

Current relay >N<, to monitor overcurrents, 1 module, 230 V AC, 5 A, 1 measuring area (from 1 to 10 A), 1 phase, 1 switch. Cancelations and returns limited. Consult conditions.

3 View Availability View Price

6EP1961-2BA41

6EP1961-2BA41

-

SITOP PSE200U 10 A Selectivity module 4-channel input: 24 V DC/40 A output: 24 V DC/4x 10 A Level adjustable 3-10 A with status message for each output *Ex approval no longer available*

3 View Availability View Price

6EP1961-2BA21

6EP1961-2BA21

-

SITOP PSE200U 10 A Selectivity module 4-channel input: 24 V DC/40 A output: 24 V DC/4x 10 A Level adjustable 3-10 A with common signaling contact *Ex approval no longer available*

3 View Availability View Price

DCRM2

DCRM2

-

REATIVE CURRENT CONTROLLER RELAY, DCRM SERIES. SINGLE AND THREE-PHASE LOW-VOLTAGE SYSTEM, 2 STEPS

REGOLAT.RIFASAMENTO 2 GR. 380-415V

Reactive current controller relay, DCRM series. Single and three-phase low-voltage system, 2 steps

3 View Availability View Price

3RR2141-1AA30

3RR2141-1AA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment Apparent current monitoring 1.6-16 A, 20-400 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system

3 View Availability View Price

3RR2141-1AW30

3RR2141-1AW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment Apparent current monitoring 1.6-16 A, 20-400 Hz, 2-phase Supply 24-240 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system

3 View Availability View Price

3RR2141-2AA30

3RR2141-2AA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 basic, analog adjustment Apparent current monitoring 1.6-16 A, 20-400 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system

3 View Availability View Price

3RR2142-1AW30

3RR2142-1AW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment Apparent current monitoring 4...40 A, 50...60 Hz, 2-phase Supply 24-240 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system

3 View Availability View Price

3RR2142-2AW30

3RR2142-2AW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S0 basic, analog adjustment Apparent current monitoring 4...40 A, 50...60 Hz, 2-phase Supply 24-240 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system

3 View Availability View Price

3RR2143-1AA30

3RR2143-1AA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 basic, analog adjustment Apparent current monitoring 8...80 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system

3 View Availability View Price

3RR2143-3AA30

3RR2143-3AA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 basic, analog adjustment Apparent current monitoring 8...80 A, 50...60 Hz, 2-phase Supply 24 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% spring-type connection system

3 View Availability View Price

3RR2143-1AW30

3RR2143-1AW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 basic, analog adjustment Apparent current monitoring 8...80 A, 50...60 Hz, 2-phase Supply 24-240 V AC/DC 1 change-over contact Monitoring for Current overshoot and undershoot Phase failure, Cable break with or without fault buffer ON delay 0-60 s Noise pulse suppression 0-30 s Switching hysteresis 6% Screw connection system

3 View Availability View Price

3RR2241-1FA30

3RR2241-1FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 standard, digitally adjustable Apparant/active current monitoring 1.6-16 A, 20-400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min Screw connection system

3 View Availability View Price

3RR2241-1FW30

3RR2241-1FW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 standard, digitally adjustable Apparant/active current monitoring 1.6-16 A, 20-400 Hz, 3-phase Supply 24-240 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min Screw connection system

3 View Availability View Price

3RR2241-2FA30

3RR2241-2FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S00 standard, digitally adjustable Apparant/active current monitoring 1.6-16 A, 20-400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min spring-type connection system

3 View Availability View Price

3RR2242-1FA30

3RR2242-1FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S0 standard, digitally adjustable Apparant/active current monitoring 4...40 A, 20...400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min Screw connection system

3 View Availability View Price

3RR2243-1FA30

3RR2243-1FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 standard, digitally adjustable Apparant/active current monitoring 8...80 A, 20...400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min Screw connection system

3 View Availability View Price

3RR2242-2FA30

3RR2242-2FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S0 standard, digitally adjustable Apparant/active current monitoring 4...40 A, 20...400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min spring-type connection system

3 View Availability View Price

3RR2243-3FA30

3RR2243-3FA30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 standard, digitally adjustable Apparant/active current monitoring 8...80 A, 20...400 Hz, 3-phase Supply 24 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min spring-type connection system

CURRENT SURVEILLANCE RELAY, S2 SIZE, 3 PHASES, DIGITAL ADJUSTMENT 8-80A, 3RT2 CONTACTOR MOUNTING, V POWER SUPPLY 24V AC/DC, 1 SWITCHED + 1 SOLID STATE OUTPUT FOR WARNING AND ALARM, SPRING TERMINALS

3 View Availability View Price

3RR2243-3FW30

3RR2243-3FW30

-

Monitoring relay, can be mounted to Contactor 3RT2, Size S2 standard, digitally adjustable Apparant/active current monitoring 8...80 A, 20...400 Hz, 3-phase Supply 24-240 V AC/DC 1 change-over contact, 1 semiconductor output for alarm and warning Monitoring for Current overshoot and undershoot Phase failure, Cable break Phase sequence Residual current Blocking current Warning and alarm thresholds with or without fault buffer ON delay 0-99 s Noise pulse suppression 0-30 s Pause after fault 0-300 min spring-type connection system

3 View Availability View Price

3RR2441-2AA40

3RR2441-2AA40

-

Current monitoring relay for IO-Link, can be mounted to Contactor 3RT2, Size S00 Apparant/active current monitoring 1.6-16 A, 20-400 Hz, 3-phase Supply voltage 24 V DC 1 change-over contact Monitoring for Current overshoot and undershoot Current asymmetry Phase failure, Cable break Phase sequence, Residual current Blocking current, Switching cycle and Operating hours counter Warning and alarm thresholds Auto-reset or manual reset ON delay 0-9999.9 s OFF delay 0-9999.9 s Reclosing delay 0-300 min spring-type connection system

3 View Availability View Price

3RR2442-1AA40

3RR2442-1AA40

-

Current monitoring relay for IO-Link, can be mounted to Contactor 3RT2, Size S0 Apparant/active current monitoring 4-40 A, 20-400 Hz, 3-phase Supply voltage 24 V DC 1 change-over contact Monitoring for Current overshoot and undershoot Current asymmetry Phase failure, Cable break Phase sequence, Residual current Blocking current, Switching cycle and Operating hours counter Warning and alarm thresholds Auto-reset or manual reset ON delay 0-9999.9 s OFF delay 0-9999.9 s Reclosing delay 0-300 min Screw connection system

3 View Availability View Price

6EP1961-2BA61

6EP1961-2BA61

-

SITOP PSE200U 3 A NEC Class 2 Selectivity module 4-channel input: 24 V DC/12 A output: 24 V/4x 3 A NEC class 2 threshold value adjustable 0.5-3 A with status message for each output *Ex approval no longer available*

3 View Availability View Price

1SVR730841R1300

1SVR730841R1300

-

CM-SRS.12S Current monitoring relay 1c/o, B-C=0.3-15A RMS, 220-240VAC

CM-SRS.12S RELe CTRL CURRENT 1 C/C TOR

CM-SRS.12S Current monitoring relay 1c/o, B-C=0.3-15A RMS, 220-240VAC

3 View Availability View Price

1SVR730841R0300

1SVR730841R0300

-

CM-SRS.12S Current monitoring relay 1c/o,B-C=0.3-15A RMS, 110-130VAC

CM-SRS.12S RELe CTRL CURRENT 1 C/C TOR

CM-SRS.12S Current monitoring relay 1c/o,B-C=0.3-15A RMS, 110-130VAC

3 View Availability View Price

1SVR730841R0200

1SVR730841R0200

-

CM-SRS.11S Current monitoring relay 1c/o, B-C=3mA-1A RMS, 110-130VAC

CM-SRS.11S RELe CTRL CURRENT 1 C/C TOR

CM-SRS.11S Current monitoring relay 1c/o, B-C=3mA-1A RMS, 110-130VAC

0 Stock Available View Price

1SVR730841R1200

1SVR730841R1200

-

CM-SRS.11S Current monitoring relay 1c/o, B-C=3mA-1A RMS, 220-240VAC

CM-SRS.11S RELe CTRL CURRENT 1 C/C TOR

CM-SRS.11S Current monitoring relay 1c/o, B-C=3mA-1A RMS, 220-240VAC

3 View Availability View Price

1SVR740841R0200

1SVR740841R0200

-

CM-SRS.11P Current monitoring relay 1c/o, B-C=3mA-1A RMS, 110-130VAC

CM-SRS.11P RELe CTRL CURRENT 1 C/C RES

CM-SRS.11P Current monitoring relay 1c/o, B-C=3mA-1A RMS, 110-130VAC

3 View Availability View Price

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.